3.6CVNov 30, 2025Code
TAP-CT: 3D Task-Agnostic Pretraining of Computed Tomography Foundation ModelsTim Veenboer, George Yiasemis, Eric Marcus et al.
Existing foundation models (FMs) in the medical domain often require extensive fine-tuning or rely on training resource-intensive decoders, while many existing encoders are pretrained with objectives biased toward specific tasks. This illustrates a need for a strong, task-agnostic foundation model that requires minimal fine-tuning beyond feature extraction. In this work, we introduce a suite of task-agnostic pretraining of CT foundation models (TAP-CT): a simple yet effective adaptation of Vision Transformers (ViTs) and DINOv2 for volumetric data, enabling scalable self-supervised pretraining directly on 3D CT volumes. Our approach incorporates targeted modifications to patch embeddings, positional encodings, and volumetric augmentations, making the architecture depth-aware while preserving the simplicity of the underlying architectures. We show that large-scale 3D pretraining on an extensive in-house CT dataset (105K volumes) yields stable, robust frozen representations that generalize strongly across downstream tasks. To promote transparency and reproducibility, and to establish a powerful, low-resource baseline for future research in medical imaging, we will release all pretrained models, experimental configurations, and downstream benchmark code at https://huggingface.co/fomofo/tap-ct-b-3d.
13.3IVSep 10, 2024
Ordinal Learning: Longitudinal Attention Alignment Model for Predicting Time to Future Breast Cancer Events from MammogramsXin Wang, Tao Tan, Yuan Gao et al.
Precision breast cancer (BC) risk assessment is crucial for developing individualized screening and prevention. Despite the promising potential of recent mammogram (MG) based deep learning models in predicting BC risk, they mostly overlook the 'time-to-future-event' ordering among patients and exhibit limited explorations into how they track history changes in breast tissue, thereby limiting their clinical application. In this work, we propose a novel method, named OA-BreaCR, to precisely model the ordinal relationship of the time to and between BC events while incorporating longitudinal breast tissue changes in a more explainable manner. We validate our method on public EMBED and inhouse datasets, comparing with existing BC risk prediction and time prediction methods. Our ordinal learning method OA-BreaCR outperforms existing methods in both BC risk and time-to-future-event prediction tasks. Additionally, ordinal heatmap visualizations show the model's attention over time. Our findings underscore the importance of interpretable and precise risk assessment for enhancing BC screening and prevention efforts. The code will be accessible to the public.
29.3LGJan 29, 2025
Current Pathology Foundation Models are unrobust to Medical Center DifferencesEdwin D. de Jong, Eric Marcus, Jonas Teuwen
Pathology Foundation Models (FMs) hold great promise for healthcare. Before they can be used in clinical practice, it is essential to ensure they are robust to variations between medical centers. We measure whether pathology FMs focus on biological features like tissue and cancer type, or on the well known confounding medical center signatures introduced by staining procedure and other differences. We introduce the Robustness Index. This novel robustness metric reflects to what degree biological features dominate confounding features. Ten current publicly available pathology FMs are evaluated. We find that all current pathology foundation models evaluated represent the medical center to a strong degree. Significant differences in the robustness index are observed. Only one model so far has a robustness index greater than one, meaning biological features dominate confounding features, but only slightly. A quantitative approach to measure the influence of medical center differences on FM-based prediction performance is described. We analyze the impact of unrobustness on classification performance of downstream models, and find that cancer-type classification errors are not random, but specifically attributable to same-center confounders: images of other classes from the same medical center. We visualize FM embedding spaces, and find these are more strongly organized by medical centers than by biological factors. As a consequence, the medical center of origin is predicted more accurately than the tissue source and cancer type. The robustness index introduced here is provided with the aim of advancing progress towards clinical adoption of robust and reliable pathology FMs.
14.5IVJan 4, 2024
Nodule detection and generation on chest X-rays: NODE21 ChallengeEcem Sogancioglu, Bram van Ginneken, Finn Behrendt et al.
Pulmonary nodules may be an early manifestation of lung cancer, the leading cause of cancer-related deaths among both men and women. Numerous studies have established that deep learning methods can yield high-performance levels in the detection of lung nodules in chest X-rays. However, the lack of gold-standard public datasets slows down the progression of the research and prevents benchmarking of methods for this task. To address this, we organized a public research challenge, NODE21, aimed at the detection and generation of lung nodules in chest X-rays. While the detection track assesses state-of-the-art nodule detection systems, the generation track determines the utility of nodule generation algorithms to augment training data and hence improve the performance of the detection systems. This paper summarizes the results of the NODE21 challenge and performs extensive additional experiments to examine the impact of the synthetically generated nodule training images on the detection algorithm performance.
26.0IVJul 22, 2025
Towards Robust Foundation Models for Digital PathologyJonah Kömen, Edwin D. de Jong, Julius Hense et al.
Biomedical Foundation Models (FMs) are rapidly transforming AI-enabled healthcare research and entering clinical validation. However, their susceptibility to learning non-biological technical features -- including variations in surgical/endoscopic techniques, laboratory procedures, and scanner hardware -- poses risks for clinical deployment. We present the first systematic investigation of pathology FM robustness to non-biological features. Our work (i) introduces measures to quantify FM robustness, (ii) demonstrates the consequences of limited robustness, and (iii) proposes a framework for FM robustification to mitigate these issues. Specifically, we developed PathoROB, a robustness benchmark with three novel metrics, including the robustness index, and four datasets covering 28 biological classes from 34 medical centers. Our experiments reveal robustness deficits across all 20 evaluated FMs, and substantial robustness differences between them. We found that non-robust FM representations can cause major diagnostic downstream errors and clinical blunders that prevent safe clinical adoption. Using more robust FMs and post-hoc robustification considerably reduced (but did not yet eliminate) the risk of such errors. This work establishes that robustness evaluation is essential for validating pathology FMs before clinical adoption and demonstrates that future FM development must integrate robustness as a core design principle. PathoROB provides a blueprint for assessing robustness across biomedical domains, guiding FM improvement efforts towards more robust, representative, and clinically deployable AI systems that prioritize biological information over technical artifacts.
16.7IVJun 10, 2025
Foundation Models in Medical Imaging: A Review and OutlookVivien van Veldhuizen, Vanessa Botha, Chunyao Lu et al.
Foundation models (FMs) are changing the way medical images are analyzed by learning from large collections of unlabeled data. Instead of relying on manually annotated examples, FMs are pre-trained to learn general-purpose visual features that can later be adapted to specific clinical tasks with little additional supervision. In this review, we examine how FMs are being developed and applied in pathology, radiology, and ophthalmology, drawing on evidence from over 150 studies. We explain the core components of FM pipelines, including model architectures, self-supervised learning methods, and strategies for downstream adaptation. We also review how FMs are being used in each imaging domain and compare design choices across applications. Finally, we discuss key challenges and open questions to guide future research.