Julián Acosta

CV
h-index22
10papers
119citations
Novelty40%
AI Score40

10 Papers

9.6AIAug 26, 2024Code
Uncovering Knowledge Gaps in Radiology Report Generation Models through Knowledge Graphs

Xiaoman Zhang, Julián N. Acosta, Hong-Yu Zhou et al.

Recent advancements in artificial intelligence have significantly improved the automatic generation of radiology reports. However, existing evaluation methods fail to reveal the models' understanding of radiological images and their capacity to achieve human-level granularity in descriptions. To bridge this gap, we introduce a system, named ReXKG, which extracts structured information from processed reports to construct a comprehensive radiology knowledge graph. We then propose three metrics to evaluate the similarity of nodes (ReXKG-NSC), distribution of edges (ReXKG-AMS), and coverage of subgraphs (ReXKG-SCS) across various knowledge graphs. We conduct an in-depth comparative analysis of AI-generated and human-written radiology reports, assessing the performance of both specialist and generalist models. Our study provides a deeper understanding of the capabilities and limitations of current AI models in radiology report generation, offering valuable insights for improving model performance and clinical applicability.

4.8CLSep 17, 2024
ReXErr: Synthesizing Clinically Meaningful Errors in Diagnostic Radiology Reports

Vishwanatha M. Rao, Serena Zhang, Julian N. Acosta et al.

Accurately interpreting medical images and writing radiology reports is a critical but challenging task in healthcare. Both human-written and AI-generated reports can contain errors, ranging from clinical inaccuracies to linguistic mistakes. To address this, we introduce ReXErr, a methodology that leverages Large Language Models to generate representative errors within chest X-ray reports. Working with board-certified radiologists, we developed error categories that capture common mistakes in both human and AI-generated reports. Our approach uses a novel sampling scheme to inject diverse errors while maintaining clinical plausibility. ReXErr demonstrates consistency across error categories and produces errors that closely mimic those found in real-world scenarios. This method has the potential to aid in the development and evaluation of report correction algorithms, potentially enhancing the quality and reliability of radiology reporting.

4.2AISep 19, 2024
HeadCT-ONE: Enabling Granular and Controllable Automated Evaluation of Head CT Radiology Report Generation

Julián N. Acosta, Xiaoman Zhang, Siddhant Dogra et al.

We present Head CT Ontology Normalized Evaluation (HeadCT-ONE), a metric for evaluating head CT report generation through ontology-normalized entity and relation extraction. HeadCT-ONE enhances current information extraction derived metrics (such as RadGraph F1) by implementing entity normalization through domain-specific ontologies, addressing radiological language variability. HeadCT-ONE compares normalized entities and relations, allowing for controllable weighting of different entity types or specific entities. Through experiments on head CT reports from three health systems, we show that HeadCT-ONE's normalization and weighting approach improves the capture of semantically equivalent reports, better distinguishes between normal and abnormal reports, and aligns with radiologists' assessment of clinically significant errors, while offering flexibility to prioritize specific aspects of report content. Our results demonstrate how HeadCT-ONE enables more flexible, controllable, and granular automated evaluation of head CT reports.

7.6CVMar 19
ReXInTheWild: A Unified Benchmark for Medical Photograph Understanding

Oishi Banerjee, Sung Eun Kim, Alexandra N. Willauer et al.

Everyday photographs taken with ordinary cameras are already widely used in telemedicine and other online health conversations, yet no comprehensive benchmark evaluates whether vision-language models can interpret their medical content. Analyzing these images requires both fine-grained natural image understanding and domain-specific medical reasoning, a combination that challenges both general-purpose and specialized models. We introduce ReXInTheWild, a benchmark of 955 clinician-verified multiple-choice questions spanning seven clinical topics across 484 photographs sourced from the biomedical literature. When evaluated on ReXInTheWild, leading multimodal large language models show substantial performance variation: Gemini-3 achieves 78% accuracy, followed by Claude Opus 4.5 (72%) and GPT-5 (68%), while the medical specialist model MedGemma reaches only 37%. A systematic error analysis also reveals four categories of common errors, ranging from low-level geometric errors to high-level reasoning failures and requiring different mitigation strategies. ReXInTheWild provides a challenging, clinically grounded benchmark at the intersection of natural image understanding and medical reasoning. The dataset is available on HuggingFace.

23.5CVMay 13, 2024
MedVersa: A Generalist Foundation Model for Medical Image Interpretation

Hong-Yu Zhou, Julián Nicolás Acosta, Subathra Adithan et al.

Current medical AI systems are often limited to narrow applications, hindering widespread adoption. We present MedVersa, a generalist foundation model trained on tens of millions of compiled medical instances. MedVersa unlocks generalist learning from multimodal inputs and outputs, representing the first example of a generalist model reaching competitive performance with leading specialized solutions across a variety of medical imaging scenarios. MedVersa achieves state-of-the-art performance in nine tasks, sometimes outperforming counterparts by over 10%. Radiologist evaluation shows MedVersa-generated reports get superior performance in 95% of normal studies, while matching or exceeding human reports in 71% of cases overall. User studies showed notable reductions in report writing time and discrepancies with the use of MedVersa. Our findings underscore the value of flexible, multimodal AI systems in advancing medical image interpretation and supporting clinical expertise.

17.8CVNov 22, 2024
ReXrank: A Public Leaderboard for AI-Powered Radiology Report Generation

Xiaoman Zhang, Hong-Yu Zhou, Xiaoli Yang et al.

AI-driven models have demonstrated significant potential in automating radiology report generation for chest X-rays. However, there is no standardized benchmark for objectively evaluating their performance. To address this, we present ReXrank, https://rexrank.ai, a public leaderboard and challenge for assessing AI-powered radiology report generation. Our framework incorporates ReXGradient, the largest test dataset consisting of 10,000 studies, and three public datasets (MIMIC-CXR, IU-Xray, CheXpert Plus) for report generation assessment. ReXrank employs 8 evaluation metrics and separately assesses models capable of generating only findings sections and those providing both findings and impressions sections. By providing this standardized evaluation framework, ReXrank enables meaningful comparisons of model performance and offers crucial insights into their robustness across diverse clinical settings. Beyond its current focus on chest X-rays, ReXrank's framework sets the stage for comprehensive evaluation of automated reporting across the full spectrum of medical imaging.

13.5CVNov 1, 2024
RadFlag: A Black-Box Hallucination Detection Method for Medical Vision Language Models

Serena Zhang, Sraavya Sambara, Oishi Banerjee et al.

Generating accurate radiology reports from medical images is a clinically important but challenging task. While current Vision Language Models (VLMs) show promise, they are prone to generating hallucinations, potentially compromising patient care. We introduce RadFlag, a black-box method to enhance the accuracy of radiology report generation. Our method uses a sampling-based flagging technique to find hallucinatory generations that should be removed. We first sample multiple reports at varying temperatures and then use a Large Language Model (LLM) to identify claims that are not consistently supported across samples, indicating that the model has low confidence in those claims. Using a calibrated threshold, we flag a fraction of these claims as likely hallucinations, which should undergo extra review or be automatically rejected. Our method achieves high precision when identifying both individual hallucinatory sentences and reports that contain hallucinations. As an easy-to-use, black-box system that only requires access to a model's temperature parameter, RadFlag is compatible with a wide range of radiology report generation models and has the potential to broadly improve the quality of automated radiology reporting.

8.3HCDec 16, 2024
The Impact of AI Assistance on Radiology Reporting: A Pilot Study Using Simulated AI Draft Reports

Julián N. Acosta, Siddhant Dogra, Subathra Adithan et al.

Radiologists face increasing workload pressures amid growing imaging volumes, creating risks of burnout and delayed reporting times. While artificial intelligence (AI) based automated radiology report generation shows promise for reporting workflow optimization, evidence of its real-world impact on clinical accuracy and efficiency remains limited. This study evaluated the effect of draft reports on radiology reporting workflows by conducting a three reader multi-case study comparing standard versus AI-assisted reporting workflows. In both workflows, radiologists reviewed the cases and modified either a standard template (standard workflow) or an AI-generated draft report (AI-assisted workflow) to create the final report. For controlled evaluation, we used GPT-4 to generate simulated AI drafts and deliberately introduced 1-3 errors in half the cases to mimic real AI system performance. The AI-assisted workflow significantly reduced average reporting time from 573 to 435 seconds (p=0.003), without a statistically significant difference in clinically significant errors between workflows. These findings suggest that AI-generated drafts can meaningfully accelerate radiology reporting while maintaining diagnostic accuracy, offering a practical solution to address mounting workload challenges in clinical practice.

6.3IVDec 17, 2024
a2z-1 for Multi-Disease Detection in Abdomen-Pelvis CT: External Validation and Performance Analysis Across 21 Conditions

Pranav Rajpurkar, Julian N. Acosta, Siddhant Dogra et al.

We present a comprehensive evaluation of a2z-1, an artificial intelligence (AI) model designed to analyze abdomen-pelvis CT scans for 21 time-sensitive and actionable findings. Our study focuses on rigorous assessment of the model's performance and generalizability. Large-scale retrospective analysis demonstrates an average AUC of 0.931 across 21 conditions. External validation across two distinct health systems confirms consistent performance (AUC 0.923), establishing generalizability to different evaluation scenarios, with notable performance in critical findings such as small bowel obstruction (AUC 0.958) and acute pancreatitis (AUC 0.961). Subgroup analysis shows consistent accuracy across patient sex, age groups, and varied imaging protocols, including different slice thicknesses and contrast administration types. Comparison of high-confidence model outputs to radiologist reports reveals instances where a2z-1 identified overlooked findings, suggesting potential for quality assurance applications.

4.1HCJun 25, 2025
Voice-guided Orchestrated Intelligence for Clinical Evaluation (VOICE): A Voice AI Agent System for Prehospital Stroke Assessment

Julian Acosta, Scott Adams, Julius Kernbach et al.

We developed a voice-driven artificial intelligence (AI) system that guides anyone - from paramedics to family members - through expert-level stroke evaluations using natural conversation, while also enabling smartphone video capture of key examination components for documentation and potential expert review. This addresses a critical gap in emergency care: current stroke recognition by first responders is inconsistent and often inaccurate, with sensitivity for stroke detection as low as 58%, causing life-threatening delays in treatment. Three non-medical volunteers used our AI system to assess ten simulated stroke patients, including cases with likely large vessel occlusion (LVO) strokes and stroke-like conditions, while we measured diagnostic accuracy, completion times, user confidence, and expert physician review of the AI-generated reports. The AI system correctly identified 84% of individual stroke signs and detected 75% of likely LVOs, completing evaluations in just over 6 minutes. Users reported high confidence (median 4.5/5) and ease of use (mean 4.67/5). The system successfully identified 86% of actual strokes but also incorrectly flagged 2 of 3 non-stroke cases as strokes. When an expert physician reviewed the AI reports with videos, they identified the correct diagnosis in 100% of cases, but felt confident enough to make preliminary treatment decisions in only 40% of cases due to observed AI errors including incorrect scoring and false information. While the current system's limitations necessitate human oversight, ongoing rapid advancements in speech-to-speech AI models suggest that future versions are poised to enable highly accurate assessments. Achieving human-level voice interaction could transform emergency medical care, putting expert-informed assessment capabilities in everyone's hands.