1.2TOMar 4, 2025
Passive Heart Rate Monitoring During Smartphone Use in Everyday LifeShun Liao, Paolo Di Achille, Jiang Wu et al.
Resting heart rate (RHR) is an important biomarker of cardiovascular health and mortality, but tracking it longitudinally generally requires a wearable device, limiting its availability. We present PHRM, a deep learning system for passive heart rate (HR) and RHR measurements during everyday smartphone use, using facial video-based photoplethysmography. Our system was developed using 225,773 videos from 495 participants and validated on 185,970 videos from 205 participants in laboratory and free-living conditions, representing the largest validation study of its kind. Compared to reference electrocardiogram, PHRM achieved a mean absolute percentage error (MAPE) < 10% for HR measurements across three skin tone groups of light, medium and dark pigmentation; MAPE for each skin tone group was non-inferior versus the others. Daily RHR measured by PHRM had a mean absolute error < 5 bpm compared to a wearable HR tracker, and was associated with known risk factors. These results highlight the potential of smartphones to enable passive and equitable heart health monitoring.
1.2SPJul 14, 2025
UWB Radar-based Heart Rate Monitoring: A Transfer Learning ApproachElzbieta Gruzewska, Pooja Rao, Sebastien Baur et al.
Radar technology presents untapped potential for continuous, contactless, and passive heart rate monitoring via consumer electronics like mobile phones. However the variety of available radar systems and lack of standardization means that a large new paired dataset collection is required for each radar system. This study demonstrates transfer learning between frequency-modulated continuous wave (FMCW) and impulse-radio ultra-wideband (IR-UWB) radar systems, both increasingly integrated into consumer devices. FMCW radar utilizes a continuous chirp, while IR-UWB radar employs short pulses. Our mm-wave FMCW radar operated at 60 GHz with a 5.5 GHz bandwidth (2.7 cm resolution, 3 receiving antennas [Rx]), and our IR-UWB radar at 8 GHz with a 500 MHz bandwidth (30 cm resolution, 2 Rx). Using a novel 2D+1D ResNet architecture we achieved a mean absolute error (MAE) of 0.85 bpm and a mean absolute percentage error (MAPE) of 1.42% for heart rate monitoring with FMCW radar (N=119 participants, an average of 8 hours per participant). This model maintained performance (under 5 MAE/10% MAPE) across various body positions and heart rate ranges, with a 98.9% recall. We then fine-tuned a variant of this model, trained on single-antenna and single-range bin FMCW data, using a small (N=376, avg 6 minutes per participant) IR-UWB dataset. This transfer learning approach yielded a model with MAE 4.1 bpm and MAPE 6.3% (97.5% recall), a 25% MAE reduction over the IR-UWB baseline. This demonstration of transfer learning between radar systems for heart rate monitoring has the potential to accelerate its introduction into existing consumer devices.
3.6CVJun 29, 2025
A High-Throughput Platform to Bench Test Smartphone-Based Heart Rate Measurements Derived From VideoMing-Zher Poh, Jonathan Wang, Jonathan Hsu et al.
Smartphone-based heart rate (HR) monitoring apps using finger-over-camera photoplethysmography (PPG) face significant challenges in performance evaluation and device compatibility due to device variability and fragmentation. Manual testing is impractical, and standardized methods are lacking. This paper presents a novel, high-throughput bench-testing platform to address this critical need. We designed a system comprising a test rig capable of holding 12 smartphones for parallel testing, a method for generating synthetic PPG test videos with controllable HR and signal quality, and a host machine for coordinating video playback and data logging. The system achieved a mean absolute percentage error (MAPE) of 0.11% +/- 0.001% between input and measured HR, and a correlation coefficient of 0.92 +/- 0.008 between input and measured PPG signals using a clinically-validated smartphone-based HR app. Bench-testing results of 20 different smartphone models correctly classified all the devices as meeting the ANSI/CTA accuracy standards for HR monitors (MAPE <10%) when compared to a prospective clinical study with 80 participants, demonstrating high positive predictive value. This platform offers a scalable solution for pre-deployment testing of smartphone HR apps to improve app performance, ensure device compatibility, and advance the field of mobile health.