Ziqi Zhao

RO
h-index18
4papers
91citations
Novelty57%
AI Score33

4 Papers

7.9LGNov 22, 2024Code
Geminio: Language-Guided Gradient Inversion Attacks in Federated Learning

Junjie Shan, Ziqi Zhao, Jialin Lu et al.

Foundation models that bridge vision and language have made significant progress. While they have inspired many life-enriching applications, their potential for abuse in creating new threats remains largely unexplored. In this paper, we reveal that vision-language models (VLMs) can be weaponized to enhance gradient inversion attacks (GIAs) in federated learning (FL), where an FL server attempts to reconstruct private data samples from gradients shared by victim clients. Despite recent advances, existing GIAs struggle to reconstruct high-resolution images when the victim has a large local data batch. One promising direction is to focus reconstruction on valuable samples rather than the entire batch, but current methods lack the flexibility to target specific data of interest. To address this gap, we propose Geminio, the first approach to transform GIAs into semantically meaningful, targeted attacks. It enables a brand new privacy attack experience: attackers can describe, in natural language, the data they consider valuable, and Geminio will prioritize reconstruction to focus on those high-value samples. This is achieved by leveraging a pretrained VLM to guide the optimization of a malicious global model that, when shared with and optimized by a victim, retains only gradients of samples that match the attacker-specified query. Geminio can be launched at any FL round and has no impact on normal training (i.e., the FL server can steal clients' data while still producing a high-utility ML model as in benign scenarios). Extensive experiments demonstrate its effectiveness in pinpointing and reconstructing targeted samples, with high success rates across complex datasets and large batch sizes with resilience against defenses.

7.3RONov 3, 2021
Autonomous Magnetic Navigation Framework for Active Wireless Capsule Endoscopy Inspired by Conventional Colonoscopy Procedures

Yangxin Xu, Keyu Li, Ziqi Zhao et al.

In recent years, simultaneous magnetic actuation and localization (SMAL) for active wireless capsule endoscopy (WCE) has been intensively studied to improve the efficiency and accuracy of the examination. In this paper, we propose an autonomous magnetic navigation framework for active WCE that mimics the "insertion" and "withdrawal" procedures performed by an expert physician in conventional colonoscopy, thereby enabling efficient and accurate navigation of a robotic capsule endoscope in the intestine with minimal user effort. First, the capsule is automatically propelled through the unknown intestinal environment and generate a viable path to represent the environment. Then, the capsule is autonomously navigated towards any point selected on the intestinal trajectory to allow accurate and repeated inspections of suspicious lesions. Moreover, we implement the navigation framework on a robotic system incorporated with advanced SMAL algorithms, and validate it in the navigation in various tubular environments using phantoms and an ex-vivo pig colon. Our results demonstrate that the proposed autonomous navigation framework can effectively navigate the capsule in unknown, complex tubular environments with a satisfactory accuracy, repeatability and efficiency compared with manual operation.

10.4ROAug 25, 2021
Adaptive Simultaneous Magnetic Actuation and Localization for WCE in a Tubular Environment

Yangxin Xu, Keyu Li, Ziqi Zhao et al.

Simultaneous Magnetic Actuation and Localization (SMAL) is a promising technology for active wireless capsule endoscopy (WCE). In this paper, an adaptive SMAL system is presented to efficiently propel and precisely locate a capsule in a tubular environment with complex shapes. In order to track the capsule with high localization accuracy and update frequency in a large workspace, we propose a mechanism that can automatically activate a sub-array of sensors with the optimal layout during the capsule movement. The improved multiple objects tracking (IMOT) method is simplified and adapted to our system to estimate the 6-D pose of the capsule in real time. Also, we study the locomotion of a magnetically actuated capsule in a tubular environment, and formulate a method to adaptively adjust the pose of the actuator to improve the propulsion efficiency. Our presented methods are applicable to other permanent magnet-based SMAL systems, and help to improve the actuation efficiency of active WCE. We verify the effectiveness of our proposed system in extensive experiments on phantoms and ex-vivo animal organs. The results demonstrate that our system can achieve convincing performance compared with the state-of-the-art ones in terms of actuation efficiency, workspace size, robustness, localization accuracy and update frequency.

10.4ROAug 25, 2021
On Reciprocally Rotating Magnetic Actuation of a Robotic Capsule in Unknown Tubular Environments

Yangxin Xu, Keyu Li, Ziqi Zhao et al.

Active wireless capsule endoscopy (WCE) based on simultaneous magnetic actuation and localization (SMAL) techniques holds great promise for improving diagnostic accuracy, reducing examination time and relieving operator burden. To date, the rotating magnetic actuation methods have been constrained to use a continuously rotating permanent magnet. In this paper, we first propose the reciprocally rotating magnetic actuation (RRMA) approach for active WCE to enhance patient safety. We first show how to generate a desired reciprocally rotating magnetic field for capsule actuation, and provide a theoretical analysis of the potential risk of causing volvulus due to the capsule motion. Then, an RRMA-based SMAL workflow is presented to automatically propel a capsule in an unknown tubular environment. We validate the effectiveness of our method in real-world experiments to automatically propel a robotic capsule in an ex-vivo pig colon. The experiment results show that our approach can achieve efficient and robust propulsion of the capsule with an average moving speed of $2.48 mm/s$ in the pig colon, and demonstrate the potential of using RRMA to enhance patient safety, reduce the inspection time, and improve the clinical acceptance of this technology.