Emma Stewart

SY
h-index26
4papers
149citations
Novelty29%
AI Score19

4 Papers

1.2SYSep 30, 2016
Automated Anomaly Detection in Distribution Grids Using $μ$PMU Measurements

Mahdi Jamei, Anna Scaglione, Ciaran Roberts et al.

The impact of Phasor Measurement Units (PMUs) for providing situational awareness to transmission system operators has been widely documented. Micro-PMUs ($μ$PMUs) are an emerging sensing technology that can provide similar benefits to Distribution System Operators (DSOs), enabling a level of visibility into the distribution grid that was previously unattainable. In order to support the deployment of these high resolution sensors, the automation of data analysis and prioritizing communication to the DSO becomes crucial. In this paper, we explore the use of $μ$PMUs to detect anomalies on the distribution grid. Our methodology is motivated by growing concern about failures and attacks to distribution automation equipment. The effectiveness of our approach is demonstrated through both real and simulated data.

1.2SYJul 13, 2016
Towards Real-Time Estimation of Solar Generation From Micro-Synchrophasor Measurements

Emre C. Kara, Ciaran M. Roberts, Michaelangelo Tabone et al.

This paper presents a set of methods for estimating the renewable energy generation downstream of a measurement device using real-world measurements. First, we present a generation disaggregation scheme where the only information available for estimation is the micro-synchrophasor measurements obtained at the substation or feeder head. We then propose two strategies in which we use measurements from the substation as well as a proxy solar irradiance measurement. Using these two measurement points, we first propose a multiple linear regression strategy, in which we estimate a relationship between the measured reactive power and the load active power consumption, which are then used in disaggregation. Finally, we expand this strategy to strategically manage the reconstruction errors in the estimators. We simultaneously disaggregate the solar generation and load. We show that it is possible to disaggragate the generation of a 7.5 megawatt photovoltaic site with a root-mean-squared error of approximately 450 kilowatts.

4.3SYDec 11, 2019
Event Detection in Micro-PMU Data: A Generative Adversarial Network Scoring Method

Armin Aligholian, Alireza Shahsavari, Ed Cortez et al.

A new data-driven method is proposed to detect events in the data streams from distribution-level phasor measurement units, a.k.a., micro-PMUs. The proposed method is developed by constructing unsupervised deep learning anomaly detection models; thus, providing event detection algorithms that require no or minimal human knowledge. First, we develop the core components of our approach based on a Generative Adversarial Network (GAN) model. We refer to this method as the basic method. It uses the same features that are often used in the literature to detect events in micro-PMU data. Next, we propose a second method, which we refer to as the enhanced method, which is enforced with additional feature analysis. Both methods can detect point signatures on single features and also group signatures on multiple features. This capability can address the unbalanced nature of power distribution circuits. The proposed methods are evaluated using real-world micro-PMU data. We show that both methods highly outperform a state-of-the-art statistical method in terms of the event detection accuracy. The enhanced method also outperforms the basic method.

1.2SYAug 1, 2017
Anomaly Detection Using Optimally-Placed Micro-PMU Sensors in Distribution Grids

Mahdi Jamei, Anna Scaglione, Ciaran Roberts et al.

As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. In this paper, focusing on Micro-Phasor Measurement Unit ($μ$PMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and sensor fusion primitives for the detection of abnormal behavior in the control perimeter. Due to the key role of the $μ$PMU devices in our architecture, a source-constrained optimal $μ$PMU placement is also described that finds the best location of the devices with respect to our rules. The effectiveness of the proposed methods are tested through the synthetic and real $μ$PMU data.