Riad Hassan

h-index1
2papers
4citations

2 Papers

3.6IVJul 13, 2024
Size and Smoothness Aware Adaptive Focal Loss for Small Tumor Segmentation

Md Rakibul Islam, Riad Hassan, Abdullah Nazib et al.

Deep learning has achieved remarkable accuracy in medical image segmentation, particularly for larger structures with well-defined boundaries. However, its effectiveness can be challenged by factors such as irregular object shapes and edges, non-smooth surfaces, small target areas, etc. which complicate the ability of networks to grasp the intricate and diverse nature of anatomical regions. In response to these challenges, we propose an Adaptive Focal Loss (A-FL) that takes both object boundary smoothness and size into account, with the goal to improve segmentation performance in intricate anatomical regions. The proposed A-FL dynamically adjusts itself based on an object's surface smoothness, size, and the class balancing parameter based on the ratio of targeted area and background. We evaluated the performance of the A-FL on the PICAI 2022 and BraTS 2018 datasets. In the PICAI 2022 dataset, the A-FL achieved an Intersection over Union (IoU) score of 0.696 and a Dice Similarity Coefficient (DSC) of 0.769, outperforming the regular Focal Loss (FL) by 5.5% and 5.4% respectively. It also surpassed the best baseline by 2.0% and 1.2%. In the BraTS 2018 dataset, A-FL achieved an IoU score of 0.883 and a DSC score of 0.931. Our ablation experiments also show that the proposed A-FL surpasses conventional losses (this includes Dice Loss, Focal Loss, and their hybrid variants) by large margin in IoU, DSC, and other metrics. The code is available at https://github.com/rakibuliuict/AFL-CIBM.git.

5.3IVMar 19, 2023
Uncertainty Driven Bottleneck Attention U-net for Organ at Risk Segmentation

Abdullah Nazib, Riad Hassan, Zahidul Islam et al.

Organ at risk (OAR) segmentation in computed tomography (CT) imagery is a difficult task for automated segmentation methods and can be crucial for downstream radiation treatment planning. U-net has become a de-facto standard for medical image segmentation and is frequently used as a common baseline in medical image segmentation tasks. In this paper, we propose a multiple decoder U-net architecture and use the segmentation disagreement between the decoders as attention to the bottleneck of the network for segmentation refinement. While feature correlation is considered as attention in most cases, in our case it is the uncertainty from the network used as attention. For accurate segmentation, we also proposed a CT intensity integrated regularization loss. Proposed regularisation helps model understand the intensity distribution of low contrast tissues. We tested our model on two publicly available OAR challenge datasets. We also conducted the ablation on each datasets with the proposed attention module and regularization loss. Experimental results demonstrate a clear accuracy improvement on both datasets.