Yiming Zhang

h-index8
2papers
500citations

2 Papers

4.1HCOct 17, 2025
MedBuild AI: An Agent-Based Hybrid Intelligence Framework for Reshaping Agency in Healthcare Infrastructure Planning through Generative Design for Medical Architecture

Yiming Zhang, Yuejia Xu, Ziyao Wang et al.

Globally, disparities in healthcare infrastructure remain stark, leaving countless communities without access to even basic services. Traditional infrastructure planning is often slow and inaccessible, and although many architects are actively delivering humanitarian and aid-driven hospital projects worldwide, these vital efforts still fall far short of the sheer scale and urgency of demand. This paper introduces MedBuild AI, a hybrid-intelligence framework that integrates large language models (LLMs) with deterministic expert systems to rebalance the early design and conceptual planning stages. As a web-based platform, it enables any region with satellite internet access to obtain guidance on modular, low-tech, low-cost medical building designs. The system operates through three agents: the first gathers local health intelligence via conversational interaction; the second translates this input into an architectural functional program through rule-based computation; and the third generates layouts and 3D models. By embedding computational negotiation into the design process, MedBuild AI fosters a reciprocal, inclusive, and equitable approach to healthcare planning, empowering communities and redefining agency in global healthcare architecture.

4.1HCApr 3, 2025
Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact

Manh Pham Hung, Matthew Yiwen Ho, Yiming Zhang et al.

Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.