MARS: toward more efficient multi-agent collaboration for LLM reasoningXiao Wang, Jia Wang, Yijie Wang et al.
Large language models (LLMs) have achieved impressive results in natural language understanding, yet their reasoning capabilities remain limited when operating as single agents. Multi-Agent Debate (MAD) has been proposed to address this limitation by enabling collaborative reasoning among multiple models in a round-table debate manner. While effective, MAD introduces substantial computational overhead due to the number of agents involved and the frequent communication required. In this paper, we propose MARS (Multi-Agent Review System), a role-based collaboration framework inspired by the review process. In MARS, an author agent generates an initial solution, reviewer agents provide decisions and comments independently, and a meta-reviewer integrates the feedback to make the final decision and guide further revision. This design enhances reasoning quality while avoiding costly reviewer-to-reviewer interactions, thereby controlling token consumption and inference time. We compared MARS with both MAD and other state-of-the-art reasoning strategies across multiple benchmarks. Extensive experiments with different LLMs show that MARS matches the accuracy of MAD while reducing both token usage and inference time by approximately 50\%. Code is available at https://github.com/xwang97/MARS.
2.3SYSep 16, 2025
A novel approach of day-ahead cooling load prediction and optimal control for ice-based thermal energy storage (TES) system in commercial buildingsXuyuan Kang, Xiao Wang, Jingjing An et al.
Thermal energy storage (TES) is an effective method for load shifting and demand response in buildings. Optimal TES control and management are essential to improve the performance of the cooling system. Most existing TES systems operate on a fixed schedule, which cannot take full advantage of its load shifting capability, and requires extensive investigation and optimization. This study proposed a novel integrated load prediction and optimized control approach for ice-based TES in commercial buildings. A cooling load prediction model was developed and a mid-day modification mechanism was introduced into the prediction model to improve the accuracy. Based on the predictions, a rule-based control strategy was proposed according to the time-of-use tariff; the mid-day control adjustment mechanism was introduced in accordance with the mid-day prediction modifications. The proposed approach was applied in the ice-based TES system of a commercial complex in Beijing, and achieved a mean absolute error (MAE) of 389 kW and coefficient of variance of MAE of 12.5%. The integrated prediction-based control strategy achieved an energy cost saving rate of 9.9%. The proposed model was deployed in the realistic building automation system of the case building and significantly improved the efficiency and automation of the cooling system.