Chenyang Li

h-index15
2papers
717citations

2 Papers

13.3IVMar 21, 2024Code
VibNet: Vibration-Boosted Needle Detection in Ultrasound Images

Dianye Huang, Chenyang Li, Angelos Karlas et al.

Precise percutaneous needle detection is crucial for ultrasound (US)-guided interventions. However, inherent limitations such as speckles, needle-like artifacts, and low resolution make it challenging to robustly detect needles, especially when their visibility is reduced or imperceptible. To address this challenge, we propose VibNet, a learning-based framework designed to enhance the robustness and accuracy of needle detection in US images by leveraging periodic vibration applied externally to the needle shafts. VibNet integrates neural Short-Time Fourier Transform and Hough Transform modules to achieve successive sub-goals, including motion feature extraction in the spatiotemporal space, frequency feature aggregation, and needle detection in the Hough space. Due to the periodic subtle vibration, the features are more robust in the frequency domain than in the image intensity domain, making VibNet more effective than traditional intensity-based methods. To demonstrate the effectiveness of VibNet, we conducted experiments on distinct \textit{ex vivo} porcine and bovine tissue samples. The results obtained on porcine samples demonstrate that VibNet effectively detects needles even when their visibility is severely reduced, with a tip error of $1.61\pm1.56~mm$ compared to $8.15\pm9.98~mm$ for UNet and $6.63\pm7.58~mm$ for WNet, and a needle direction error of $1.64\pm1.86^{\circ}$ compared to $9.29\pm15.30^{\circ}$ for UNet and $8.54\pm17.92^{\circ}$ for WNet. Code: https://github.com/marslicy/VibNet.

3.2ROAug 9, 2025
Vibration-Based Energy Metric for Restoring Needle Alignment in Autonomous Robotic Ultrasound

Zhongyu Chen, Chenyang Li, Xuesong Li et al.

Precise needle alignment is essential for percutaneous needle insertion in robotic ultrasound-guided procedures. However, inherent challenges such as speckle noise, needle-like artifacts, and low image resolution make robust needle detection difficult, particularly when visibility is reduced or lost. In this paper, we propose a method to restore needle alignment when the ultrasound imaging plane and the needle insertion plane are misaligned. Unlike many existing approaches that rely heavily on needle visibility in ultrasound images, our method uses a more robust feature by periodically vibrating the needle using a mechanical system. Specifically, we propose a vibration-based energy metric that remains effective even when the needle is fully out of plane. Using this metric, we develop a control strategy to reposition the ultrasound probe in response to misalignments between the imaging plane and the needle insertion plane in both translation and rotation. Experiments conducted on ex-vivo porcine tissue samples using a dual-arm robotic ultrasound-guided needle insertion system demonstrate the effectiveness of the proposed approach. The experimental results show the translational error of 0.41$\pm$0.27 mm and the rotational error of 0.51$\pm$0.19 degrees.