APAug 14, 2018
Robust Computation in 2D Absolute EIT (a-EIT) Using D-bar Methods with the `exp' ApproximationS. J. Hamilton, J. L. Mueller, T. R. Santos
Objective: Absolute images have important applications in medical Electrical Impedance Tomography (EIT) imaging, but the traditional minimization and statistical based computations are very sensitive to modeling errors and noise. In this paper, it is demonstrated that D-bar reconstruction methods for absolute EIT are robust to such errors. Approach: The effects of errors in domain shape and electrode placement on absolute images computed with 2D D-bar reconstruction algorithms are studied on experimental data. Main Results: It is demonstrated with tank data from several EIT systems that these methods are quite robust to such modeling errors, and furthermore the artefacts arising from such modeling errors are similar to those occurring in classic time-difference EIT imaging. Significance: This study is promising for clinical applications where absolute EIT images are desirable, but previously thought impossible.
APNov 12, 2012
A direct D-bar reconstruction algorithm for recovering a complex conductivity in 2-DS. J. Hamilton, C. N. L. Herrera, J. L. Mueller et al.
A direct reconstruction algorithm for complex conductivities in $W^{2,\infty}(Ω)$, where $Ω$ is a bounded, simply connected Lipschitz domain in $\mathbb{R}^2$, is presented. The framework is based on the uniqueness proof by Francini [Inverse Problems 20 2000], but equations relating the Dirichlet-to-Neumann to the scattering transform and the exponentially growing solutions are not present in that work, and are derived here. The algorithm constitutes the first D-bar method for the reconstruction of conductivities and permittivities in two dimensions. Reconstructions of numerically simulated chest phantoms with discontinuities at the organ boundaries are included.
IVDec 10, 2024
Graph convolutional networks enable fast hemorrhagic stroke monitoring with electrical impedance tomographyJ. Toivanen, V. Kolehmainen, A. Paldanius et al.
Objective: To develop a fast image reconstruction method for stroke monitoring with electrical impedance tomography with image quality comparable to computationally expensive nonlinear model-based methods. Methods: A post-processing approach with graph convolutional networks is employed. Utilizing the flexibility of the graph setting, a graph U-net is trained on linear difference reconstructions from 2D simulated stroke data and applied to fully 3D images from realistic simulated and experimental data. An additional network, trained on 3D vs. 2D images, is also considered for comparison. Results: Post-processing the linear difference reconstructions through the graph U-net significantly improved the image quality, resulting in images comparable to, or better than, the time-intensive nonlinear reconstruction method (a few minutes vs. several hours). Conclusion: Pairing a fast reconstruction method, such as linear difference imaging, with post-processing through a graph U-net provided significant improvements, at a negligible computational cost. Training in the graph framework vs classic pixel-based setting (CNN) allowed the ability to train on 2D cross-sectional images and process 3D volumes providing a nearly 50x savings in data simulation costs with no noticeable loss in quality. Significance: The proposed approach of post-processing a linear difference reconstruction with the graph U-net could be a feasible approach for on-line monitoring of hemorrhagic stroke.
NANov 30, 2018
Beltrami-Net: Domain Independent Deep D-bar Learning for Absolute Imaging with Electrical Impedance Tomography (a-EIT)S. J. Hamilton, A. Hänninen, A. Hauptmann et al.
Objective: To develop, and demonstrate the feasibility of, a novel image reconstruction method for absolute Electrical Impedance Tomography (a-EIT) that pairs deep learning techniques with real-time robust D-bar methods. Approach: A D-bar method is paired with a trained Convolutional Neural Network (CNN) as a post-processing step. Training data is simulated for the network using no knowledge of the boundary shape by using an associated nonphysical Beltrami equation rather than simulating the traditional current and voltage data specific to a given domain. This allows the training data to be boundary shape independent. The method is tested on experimental data from two EIT systems (ACT4 and KIT4). Main Results: Post processing the D-bar images with a CNN produces significant improvements in image quality measured by Structural SIMilarity indices (SSIMs) as well as relative $\ell_2$ and $\ell_1$ image errors. Significance: This work demonstrates that more general networks can be trained without being specific about boundary shape, a key challenge in EIT image reconstruction. The work is promising for future studies involving databases of anatomical atlases.