Yidong Zhao

IV
h-index3
5papers
19citations
Novelty60%
AI Score40

5 Papers

10.4IVNov 3, 2023
Contrast-Agnostic Groupwise Registration by Robust PCA for Quantitative Cardiac MRI

Xinqi Li, Yi Zhang, Yidong Zhao et al.

Quantitative cardiac magnetic resonance imaging (MRI) is an increasingly important diagnostic tool for cardiovascular diseases. Yet, co-registration of all baseline images within the quantitative MRI sequence is essential for the accuracy and precision of quantitative maps. However, co-registering all baseline images from a quantitative cardiac MRI sequence remains a nontrivial task because of the simultaneous changes in intensity and contrast, in combination with cardiac and respiratory motion. To address the challenge, we propose a novel motion correction framework based on robust principle component analysis (rPCA) that decomposes quantitative cardiac MRI into low-rank and sparse components, and we integrate the groupwise CNN-based registration backbone within the rPCA framework. The low-rank component of rPCA corresponds to the quantitative mapping (i.e. limited degree of freedom in variation), while the sparse component corresponds to the residual motion, making it easier to formulate and solve the groupwise registration problem. We evaluated our proposed method on cardiac T1 mapping by the modified Look-Locker inversion recovery (MOLLI) sequence, both before and after the Gadolinium contrast agent administration. Our experiments showed that our method effectively improved registration performance over baseline methods without introducing rPCA, and reduced quantitative mapping error in both in-domain (pre-contrast MOLLI) and out-of-domain (post-contrast MOLLI) inference. The proposed rPCA framework is generic and can be integrated with other registration backbones.

8.4CVAug 28, 2025
Reverse Imaging for Wide-spectrum Generalization of Cardiac MRI Segmentation

Yidong Zhao, Peter Kellman, Hui Xue et al.

Pretrained segmentation models for cardiac magnetic resonance imaging (MRI) struggle to generalize across different imaging sequences due to significant variations in image contrast. These variations arise from changes in imaging protocols, yet the same fundamental spin properties, including proton density, T1, and T2 values, govern all acquired images. With this core principle, we introduce Reverse Imaging, a novel physics-driven method for cardiac MRI data augmentation and domain adaptation to fundamentally solve the generalization problem. Our method reversely infers the underlying spin properties from observed cardiac MRI images, by solving ill-posed nonlinear inverse problems regularized by the prior distribution of spin properties. We acquire this "spin prior" by learning a generative diffusion model from the multiparametric SAturation-recovery single-SHot acquisition sequence (mSASHA) dataset, which offers joint cardiac T1 and T2 maps. Our method enables approximate but meaningful spin-property estimates from MR images, which provide an interpretable "latent variable" that lead to highly flexible image synthesis of arbitrary novel sequences. We show that Reverse Imaging enables highly accurate segmentation across vastly different image contrasts and imaging protocols, realizing wide-spectrum generalization of cardiac MRI segmentation.

5.1IVJul 1, 2025
Physics-Informed Neural ODEs for Temporal Dynamics Modeling in Cardiac T1 Mapping

Nuno Capitão, Yi Zhang, Yidong Zhao et al.

Spin-lattice relaxation time ($T_1$) is an important biomarker in cardiac parametric mapping for characterizing myocardial tissue and diagnosing cardiomyopathies. Conventional Modified Look-Locker Inversion Recovery (MOLLI) acquires 11 breath-hold baseline images with interleaved rest periods to ensure mapping accuracy. However, prolonged scanning can be challenging for patients with poor breathholds, often leading to motion artifacts that degrade image quality. In addition, $T_1$ mapping requires voxel-wise nonlinear fitting to a signal recovery model involving an iterative estimation process. Recent studies have proposed deep-learning approaches for rapid $T_1$ mapping using shortened sequences to reduce acquisition time for patient comfort. Nevertheless, existing methods overlook important physics constraints, limiting interpretability and generalization. In this work, we present an accelerated, end-to-end $T_1$ mapping framework leveraging Physics-Informed Neural Ordinary Differential Equations (ODEs) to model temporal dynamics and address these challenges. Our method achieves high-accuracy $T_1$ estimation from a sparse subset of baseline images and ensures efficient null index estimation at test time. Specifically, we develop a continuous-time LSTM-ODE model to enable selective Look-Locker (LL) data acquisition with arbitrary time lags. Experimental results show superior performance in $T_1$ estimation for both native and post-contrast sequences and demonstrate the strong benefit of our physics-based formulation over direct data-driven $T_1$ priors.

13.4IVJul 1, 2025
Bridging Classical and Learning-based Iterative Registration through Deep Equilibrium Models

Yi Zhang, Yidong Zhao, Qian Tao

Deformable medical image registration is traditionally formulated as an optimization problem. While classical methods solve this problem iteratively, recent learning-based approaches use recurrent neural networks (RNNs) to mimic this process by unrolling the prediction of deformation fields in a fixed number of steps. However, classical methods typically converge after sufficient iterations, but learning-based unrolling methods lack a theoretical convergence guarantee and show instability empirically. In addition, unrolling methods have a practical bottleneck at training time: GPU memory usage grows linearly with the unrolling steps due to backpropagation through time (BPTT). To address both theoretical and practical challenges, we propose DEQReg, a novel registration framework based on Deep Equilibrium Models (DEQ), which formulates registration as an equilibrium-seeking problem, establishing a natural connection between classical optimization and learning-based unrolling methods. DEQReg maintains constant memory usage, enabling theoretically unlimited iteration steps. Through extensive evaluation on the public brain MRI and lung CT datasets, we show that DEQReg can achieve competitive registration performance, while substantially reducing memory consumption compared to state-of-the-art unrolling methods. We also reveal an intriguing phenomenon: the performance of existing unrolling methods first increases slightly then degrades irreversibly when the inference steps go beyond the training configuration. In contrast, DEQReg achieves stable convergence with its inbuilt equilibrium-seeking mechanism, bridging the gap between classical optimization-based and modern learning-based registration methods.

14.5IVJun 18, 2024
Deep-learning-based groupwise registration for motion correction of cardiac $T_1$ mapping

Yi Zhang, Yidong Zhao, Lu Huang et al.

Quantitative $T_1$ mapping by MRI is an increasingly important tool for clinical assessment of cardiovascular diseases. The cardiac $T_1$ map is derived by fitting a known signal model to a series of baseline images, while the quality of this map can be deteriorated by involuntary respiratory and cardiac motion. To correct motion, a template image is often needed to register all baseline images, but the choice of template is nontrivial, leading to inconsistent performance sensitive to image contrast. In this work, we propose a novel deep-learning-based groupwise registration framework, which omits the need for a template, and registers all baseline images simultaneously. We design two groupwise losses for this registration framework: the first is a linear principal component analysis (PCA) loss that enforces alignment of baseline images irrespective of the intensity variation, and the second is an auxiliary relaxometry loss that enforces adherence of intensity profile to the signal model. We extensively evaluated our method, termed ``PCA-Relax'', and other baseline methods on an in-house cardiac MRI dataset including both pre- and post-contrast $T_1$ sequences. All methods were evaluated under three distinct training-and-evaluation strategies, namely, standard, one-shot, and test-time-adaptation. The proposed PCA-Relax showed further improved performance of registration and mapping over well-established baselines. The proposed groupwise framework is generic and can be adapted to applications involving multiple images.