Md Zakir Hossain

h-index4
2papers
123citations

2 Papers

5.3CRMay 13Code
DSTAN-Med: Dual-Channel Spatiotemporal Attention with Physiological Plausibility Filtering for False Data Injection Attack Detection in IoT-Based Medical Devices

Md Mehedi Hasan, Rafiqul Islam, Md Zakir Hossain

False data injection (FDI) attacks on Internet of Medical Things (IoMT) sensor streams falsify vital signs in transit, threatening patient safety and defeating clinical monitoring systems that lack cyber-physical anomaly detection capability. Existing deep learning detectors conflate inter-sensor spatial correlations with temporal dependencies in a shared latent space, preventing disentanglement of the distinct spatial and temporal signatures that FDI attacks imprint simultaneously; no current method exploits domain knowledge to constrain outputs against physiologically impossible attack patterns. We propose DSTAN-Med, a supervised framework comprising a Dual-channel Attention Mechanism (DAM) that routes multivariate sensor windows through independent sensor-wise (SWA) and time-wise (TWA) self-attention pathways operating on orthogonal tensor axes, a residual 1D-CNN block for local temporal feature extraction, and a zero-parameter Physiological Plausibility Filter (PPF) that suppresses attack signatures violating domain-knowledge bounds. Evaluated across three IoMT sensor datasets - PhysioNet/CinC 2012 (ICU vital signs), MIMIC-III Waveform (continuous ICU waveforms), and WESAD (wearable biosensor signals) - DSTAN-Med achieves mean sensitivity gains of 7.4-8.3 percentage points over the strongest Transformer baseline (TranAD), with improvements significant at p < 0.01 (McNemar's test, Holm-Bonferroni correction). The PPF contributes independent precision gains of 3.1-4.2 percentage points at negligible sensitivity cost across all three corpora. Ablation studies confirm that each component is individually necessary; removal of residual connections alone reduces sensitivity by 14.0 percentage points. The source code is publicly available at https://github.com/mehedi93hasan/DSTAN-MED.

1.2SPMay 10, 2024Code
FunnelNet: An End-to-End Deep Learning Framework to Monitor Digital Heart Murmur in Real-Time

Md Jobayer, Md. Mehedi Hasan Shawon, Md Rakibul Hasan et al.

Objective: Heart murmurs are abnormal sounds caused by turbulent blood flow within the heart. Several diagnostic methods are available to detect heart murmurs and their severity, such as cardiac auscultation, echocardiography, phonocardiogram (PCG), etc. However, these methods have limitations, including extensive training and experience among healthcare providers, cost and accessibility of echocardiography, as well as noise interference and PCG data processing. This study aims to develop a novel end-to-end real-time heart murmur detection approach using traditional and depthwise separable convolutional networks. Methods: Continuous wavelet transform (CWT) was applied to extract meaningful features from the PCG data. The proposed network has three parts: the Squeeze net, the Bottleneck, and the Expansion net. The Squeeze net generates a compressed data representation, whereas the Bottleneck layer reduces computational complexity using a depthwise-separable convolutional network. The Expansion net is responsible for up-sampling the compressed data to a higher dimension, capturing tiny details of the representative data. Results: For evaluation, we used four publicly available datasets and achieved state-of-the-art performance in all datasets. Furthermore, we tested our proposed network on two resource-constrained devices: a Raspberry PI and an Android device, stripping it down into a tiny machine learning model (TinyML), achieving a maximum of 99.70%. Conclusion: The proposed model offers a deep learning framework for real-time accurate heart murmur detection within limited resources. Significance: It will significantly result in more accessible and practical medical services and reduced diagnosis time to assist medical professionals. The code is publicly available at TBA.