Jiangang Chen

h-index10
2papers
494citations

2 Papers

5.2CVDec 21, 2024
EasyVis2: A Real Time Multi-view 3D Visualization System for Laparoscopic Surgery Training Enhanced by a Deep Neural Network YOLOv8-Pose

Yung-Hong Sun, Gefei Shen, Jiangang Chen et al.

EasyVis2 is a system designed to provide hands-free, real-time 3D visualization for laparoscopic surgery. It incorporates a surgical trocar equipped with an array of micro-cameras, which can be inserted into the body cavity to offer an enhanced field of view and a 3D perspective of the surgical procedure. A specialized deep neural network algorithm, YOLOv8-Pose, is utilized to estimate the position and orientation of surgical instruments in each individual camera view. These multi-view estimates enable the calculation of 3D poses of surgical tools, facilitating the rendering of a 3D surface model of the instruments, overlaid on the background scene, for real-time visualization. This study presents methods for adapting YOLOv8-Pose to the EasyVis2 system, including the development of a tailored training dataset. Experimental results demonstrate that, with an identical number of cameras, the new system improves 3D reconstruction accuracy and reduces computation time. Additionally, the adapted YOLOv8-Pose system shows high accuracy in 2D pose estimation.

1.2SYNov 16, 2024
A Wearable Gait Monitoring System for 17 Gait Parameters Based on Computer Vision

Jiangang Chen, Yung-Hong Sun, Kristen Pickett et al.

We developed a shoe-mounted gait monitoring system capable of tracking up to 17 gait parameters, including gait length, step time, stride velocity, and others. The system employs a stereo camera mounted on one shoe to track a marker placed on the opposite shoe, enabling the estimation of spatial gait parameters. Additionally, a Force Sensitive Resistor (FSR) affixed to the heel of the shoe, combined with a custom-designed algorithm, is utilized to measure temporal gait parameters. Through testing on multiple participants and comparison with the gait mat, the proposed gait monitoring system exhibited notable performance, with the accuracy of all measured gait parameters exceeding 93.61%. The system also demonstrated a low drift of 4.89% during long-distance walking. A gait identification task conducted on participants using a trained Transformer model achieved 95.7% accuracy on the dataset collected by the proposed system, demonstrating that our hardware has the potential to collect long-sequence gait data suitable for integration with current Large Language Models (LLMs). The system is cost-effective, user-friendly, and well-suited for real-life measurements.