George Yiasemis

IV
h-index67
12papers
203citations
Novelty45%
AI Score43

12 Papers

CVNov 30, 2025Code
TAP-CT: 3D Task-Agnostic Pretraining of Computed Tomography Foundation Models

Tim Veenboer, George Yiasemis, Eric Marcus et al.

Existing foundation models (FMs) in the medical domain often require extensive fine-tuning or rely on training resource-intensive decoders, while many existing encoders are pretrained with objectives biased toward specific tasks. This illustrates a need for a strong, task-agnostic foundation model that requires minimal fine-tuning beyond feature extraction. In this work, we introduce a suite of task-agnostic pretraining of CT foundation models (TAP-CT): a simple yet effective adaptation of Vision Transformers (ViTs) and DINOv2 for volumetric data, enabling scalable self-supervised pretraining directly on 3D CT volumes. Our approach incorporates targeted modifications to patch embeddings, positional encodings, and volumetric augmentations, making the architecture depth-aware while preserving the simplicity of the underlying architectures. We show that large-scale 3D pretraining on an extensive in-house CT dataset (105K volumes) yields stable, robust frozen representations that generalize strongly across downstream tasks. To promote transparency and reproducibility, and to establish a powerful, low-resource baseline for future research in medical imaging, we will release all pretrained models, experimental configurations, and downstream benchmark code at https://huggingface.co/fomofo/tap-ct-b-3d.

IVJan 20, 2023
On Retrospective k-space Subsampling schemes For Deep MRI Reconstruction

George Yiasemis, Clara I. Sánchez, Jan-Jakob Sonke et al.

Acquiring fully-sampled MRI $k$-space data is time-consuming, and collecting accelerated data can reduce the acquisition time. Employing 2D Cartesian-rectilinear subsampling schemes is a conventional approach for accelerated acquisitions; however, this often results in imprecise reconstructions, even with the use of Deep Learning (DL), especially at high acceleration factors. Non-rectilinear or non-Cartesian trajectories can be implemented in MRI scanners as alternative subsampling options. This work investigates the impact of the $k$-space subsampling scheme on the quality of reconstructed accelerated MRI measurements produced by trained DL models. The Recurrent Variational Network (RecurrentVarNet) was used as the DL-based MRI-reconstruction architecture. Cartesian, fully-sampled multi-coil $k$-space measurements from three datasets were retrospectively subsampled with different accelerations using eight distinct subsampling schemes: four Cartesian-rectilinear, two Cartesian non-rectilinear, and two non-Cartesian. Experiments were conducted in two frameworks: scheme-specific, where a distinct model was trained and evaluated for each dataset-subsampling scheme pair, and multi-scheme, where for each dataset a single model was trained on data randomly subsampled by any of the eight schemes and evaluated on data subsampled by all schemes. In both frameworks, RecurrentVarNets trained and evaluated on non-rectilinearly subsampled data demonstrated superior performance, particularly for high accelerations. In the multi-scheme setting, reconstruction performance on rectilinearly subsampled data improved when compared to the scheme-specific experiments. Our findings demonstrate the potential for using DL-based methods, trained on non-rectilinearly subsampled measurements, to optimize scan time and image quality.

IVSep 18, 2023
vSHARP: variable Splitting Half-quadratic Admm algorithm for Reconstruction of inverse-Problems

George Yiasemis, Nikita Moriakov, Jan-Jakob Sonke et al.

Medical Imaging (MI) tasks, such as accelerated parallel Magnetic Resonance Imaging (MRI), often involve reconstructing an image from noisy or incomplete measurements. This amounts to solving ill-posed inverse problems, where a satisfactory closed-form analytical solution is not available. Traditional methods such as Compressed Sensing (CS) in MRI reconstruction can be time-consuming or prone to obtaining low-fidelity images. Recently, a plethora of Deep Learning (DL) approaches have demonstrated superior performance in inverse-problem solving, surpassing conventional methods. In this study, we propose vSHARP (variable Splitting Half-quadratic ADMM algorithm for Reconstruction of inverse Problems), a novel DL-based method for solving ill-posed inverse problems arising in MI. vSHARP utilizes the Half-Quadratic Variable Splitting method and employs the Alternating Direction Method of Multipliers (ADMM) to unroll the optimization process. For data consistency, vSHARP unrolls a differentiable gradient descent process in the image domain, while a DL-based denoiser, such as a U-Net architecture, is applied to enhance image quality. vSHARP also employs a dilated-convolution DL-based model to predict the Lagrange multipliers for the ADMM initialization. We evaluate vSHARP on tasks of accelerated parallel MRI Reconstruction using two distinct datasets and on accelerated parallel dynamic MRI Reconstruction using another dataset. Our comparative analysis with state-of-the-art methods demonstrates the superior performance of vSHARP in these applications.

IVOct 10, 2023
Deep Cardiac MRI Reconstruction with ADMM

George Yiasemis, Nikita Moriakov, Jan-Jakob Sonke et al.

Cardiac magnetic resonance imaging is a valuable non-invasive tool for identifying cardiovascular diseases. For instance, Cine MRI is the benchmark modality for assessing the cardiac function and anatomy. On the other hand, multi-contrast (T1 and T2) mapping has the potential to assess pathologies and abnormalities in the myocardium and interstitium. However, voluntary breath-holding and often arrhythmia, in combination with MRI's slow imaging speed, can lead to motion artifacts, hindering real-time acquisition image quality. Although performing accelerated acquisitions can facilitate dynamic imaging, it induces aliasing, causing low reconstructed image quality in Cine MRI and inaccurate T1 and T2 mapping estimation. In this work, inspired by related work in accelerated MRI reconstruction, we present a deep learning (DL)-based method for accelerated cine and multi-contrast reconstruction in the context of dynamic cardiac imaging. We formulate the reconstruction problem as a least squares regularized optimization task, and employ vSHARP, a state-of-the-art DL-based inverse problem solver, which incorporates half-quadratic variable splitting and the alternating direction method of multipliers with neural networks. We treat the problem in two setups; a 2D reconstruction and a 2D dynamic reconstruction task, and employ 2D and 3D deep learning networks, respectively. Our method optimizes in both the image and k-space domains, allowing for high reconstruction fidelity. Although the target data is undersampled with a Cartesian equispaced scheme, we train our model using both Cartesian and simulated non-Cartesian undersampling schemes to enhance generalization of the model to unseen data. Furthermore, our model adopts a deep neural network to learn and refine the sensitivity maps of multi-coil k-space data. Lastly, our method is jointly trained on both, undersampled cine and multi-contrast data.

IVNov 27, 2023
Joint Supervised and Self-supervised Learning for MRI Reconstruction

George Yiasemis, Nikita Moriakov, Clara I. Sánchez et al.

Magnetic Resonance Imaging (MRI) represents an important diagnostic modality; however, its inherently slow acquisition process poses challenges in obtaining fully-sampled $k$-space data under motion. In the absence of fully-sampled acquisitions, serving as ground truths, training deep learning algorithms in a supervised manner to predict the underlying ground truth image becomes challenging. To address this limitation, self-supervised methods have emerged as a viable alternative, leveraging available subsampled $k$-space data to train deep neural networks for MRI reconstruction. Nevertheless, these approaches often fall short when compared to supervised methods. We propose Joint Supervised and Self-supervised Learning (JSSL), a novel training approach for deep learning-based MRI reconstruction algorithms aimed at enhancing reconstruction quality in cases where target datasets containing fully-sampled $k$-space measurements are unavailable. JSSL operates by simultaneously training a model in a self-supervised learning setting, using subsampled data from the target dataset(s), and in a supervised learning manner, utilizing datasets with fully-sampled $k$-space data, referred to as proxy datasets. We demonstrate JSSL's efficacy using subsampled prostate or cardiac MRI data as the target datasets, with fully-sampled brain and knee, or brain, knee and prostate $k$-space acquisitions, respectively, as proxy datasets. Our results showcase substantial improvements over conventional self-supervised methods, validated using common image quality metrics. Furthermore, we provide theoretical motivations for JSSL and establish "rule-of-thumb" guidelines for training MRI reconstruction models. JSSL effectively enhances MRI reconstruction quality in scenarios where fully-sampled $k$-space data is not available, leveraging the strengths of supervised learning by incorporating proxy datasets.

50.4CVApr 13
LoGo-MR: Screening Breast MRI for Cancer Risk Prediction by Efficient Omni-Slice Modeling

Xin Wang, Yuan Gao, George Yiasemis et al.

Efficient and explainable breast cancer (BC) risk prediction is critical for large-scale population-based screening. Breast MRI provides functional information for personalized risk assessment. Yet effective modeling remains challenging as fully 3D CNNs capture volumetric context at high computational cost, whereas lightweight 2D CNNs fail to model inter-slice continuity. Importantly, breast MRI modeling for shor- and long-term BC risk stratification remains underexplored. In this study, we propose LoGo-MR, a 2.5D local-global structural modeling framework for five-year BC risk prediction. Aligned with clinical interpretation, our framework first employs neighbor-slice encoding to capture subtle local cues linked to short-term risk. It then integrates transformer-enhanced multiple-instance learning (MIL) to model distributed global patterns related to long-term risk and provide interpretable slice importance. We further apply this framework across axial, sagittal, and coronal planes as LoGo3-MR to capture complementary volumetric information. This multi-plane formulation enables voxel-level risk saliency mapping, which may assist radiologists in localizing risk-relevant regions during breast MRI interpretation. Evaluated on a large breast MRI screening cohort (~7.5K), our method outperforms 2D/3D baselines and existing SOTA MIL methods, achieving AUCs of 0.77-0.69 for 1- to 5-year prediction and improving C-index by ~6% over 3D CNNs. LoGo3-MR further improves overall performance with interpretable localization across three planes, and validation across seven backbones shows consistent gains. These results highlight the clinical potential of efficient MRI-based BC risk stratification for large-scale screening. Code will be released publicly.

IVMar 15, 2024
End-to-end Adaptive Dynamic Subsampling and Reconstruction for Cardiac MRI

George Yiasemis, Jan-Jakob Sonke, Jonas Teuwen

$\textbf{Background:}$ Accelerating dynamic MRI is vital for advancing clinical applications and improving patient comfort. Commonly, deep learning (DL) methods for accelerated dynamic MRI reconstruction typically rely on uniformly applying non-adaptive predetermined or random subsampling patterns across all temporal frames of the dynamic acquisition. This approach fails to exploit temporal correlations or optimize subsampling on a case-by-case basis. $\textbf{Purpose:}$ To develop an end-to-end approach for adaptive dynamic MRI subsampling and reconstruction, capable of generating customized sampling patterns maximizing at the same time reconstruction quality. $\textbf{Methods:}$ We introduce the End-to-end Adaptive Dynamic Sampling and Reconstruction (E2E-ADS-Recon) for MRI framework, which integrates an adaptive dynamic sampler (ADS) that adapts the acquisition trajectory to each case for a given acceleration factor with a state-of-the-art dynamic reconstruction network, vSHARP, for reconstructing the adaptively sampled data into a dynamic image. The ADS can produce either frame-specific patterns or unified patterns applied to all temporal frames. E2E-ADS-Recon is evaluated under both frame-specific and unified 1D or 2D sampling settings, using dynamic cine cardiac MRI data and compared with vSHARP models employing standard subsampling trajectories, as well as pipelines where ADS was replaced by parameterized samplers optimized for dataset-specific schemes. $\textbf{Results:}$ E2E-ADS-Recon exhibited superior reconstruction quality, especially at high accelerations, in terms of standard quantitative metrics (SSIM, pSNR, NMSE). $\textbf{Conclusion:}$ The proposed framework improves reconstruction quality, highlighting the importance of case-specific subsampling optimization in dynamic MRI applications.

IVNov 2, 2024
Deep Multi-contrast Cardiac MRI Reconstruction via vSHARP with Auxiliary Refinement Network

George Yiasemis, Nikita Moriakov, Jan-Jakob Sonke et al.

Cardiac MRI (CMRI) is a cornerstone imaging modality that provides in-depth insights into cardiac structure and function. Multi-contrast CMRI (MCCMRI), which acquires sequences with varying contrast weightings, significantly enhances diagnostic capabilities by capturing a wide range of cardiac tissue characteristics. However, MCCMRI is often constrained by lengthy acquisition times and susceptibility to motion artifacts. To mitigate these challenges, accelerated imaging techniques that use k-space undersampling via different sampling schemes at acceleration factors have been developed to shorten scan durations. In this context, we propose a deep learning-based reconstruction method for 2D dynamic multi-contrast, multi-scheme, and multi-acceleration MRI. Our approach integrates the state-of-the-art vSHARP model, which utilizes half-quadratic variable splitting and ADMM optimization, with a Variational Network serving as an Auxiliary Refinement Network (ARN) to better adapt to the diverse nature of MCCMRI data. Specifically, the subsampled k-space data is fed into the ARN, which produces an initial prediction for the denoising step used by vSHARP. This, along with the subsampled k-space, is then used by vSHARP to generate high-quality 2D sequence predictions. Our method outperforms traditional reconstruction techniques and other vSHARP-based models.

IVNov 27, 2024
Deep End-to-end Adaptive k-Space Sampling, Reconstruction, and Registration for Dynamic MRI

George Yiasemis, Jan-Jakob Sonke, Jonas Teuwen

Dynamic MRI enables a range of clinical applications, including cardiac function assessment, organ motion tracking, and radiotherapy guidance. However, fully sampling the dynamic k-space data is often infeasible due to time constraints and physiological motion such as respiratory and cardiac motion. This necessitates undersampling, which degrades the quality of reconstructed images. Poor image quality not only hinders visualization but also impairs the estimation of deformation fields, crucial for registering dynamic (moving) images to a static reference image. This registration enables tasks such as motion correction, treatment planning, and quantitative analysis in applications like cardiac imaging and MR-guided radiotherapy. To overcome the challenges posed by undersampling and motion, we introduce an end-to-end deep learning (DL) framework that integrates adaptive dynamic k-space sampling, reconstruction, and registration. Our approach begins with a DL-based adaptive sampling strategy, optimizing dynamic k-space acquisition to capture the most relevant data for each specific case. This is followed by a DL-based reconstruction module that produces images optimized for accurate deformation field estimation from the undersampled moving data. Finally, a registration module estimates the deformation fields aligning the reconstructed dynamic images with a static reference. The proposed framework is independent of specific reconstruction and registration modules allowing for plug-and-play integration of these components. The entire framework is jointly trained using a combination of supervised and unsupervised loss functions, enabling end-to-end optimization for improved performance across all components. Through controlled experiments and ablation studies, we validate each component, demonstrating that each choice contributes to robust motion estimation from undersampled dynamic data.

IVNov 18, 2021
Recurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI Reconstruction

George Yiasemis, Jan-Jakob Sonke, Clarisa Sánchez et al.

Magnetic Resonance Imaging can produce detailed images of the anatomy and physiology of the human body that can assist doctors in diagnosing and treating pathologies such as tumours. However, MRI suffers from very long acquisition times that make it susceptible to patient motion artifacts and limit its potential to deliver dynamic treatments. Conventional approaches such as Parallel Imaging and Compressed Sensing allow for an increase in MRI acquisition speed by reconstructing MR images from sub-sampled MRI data acquired using multiple receiver coils. Recent advancements in Deep Learning combined with Parallel Imaging and Compressed Sensing techniques have the potential to produce high-fidelity reconstructions from highly accelerated MRI data. In this work we present a novel Deep Learning-based Inverse Problem solver applied to the task of Accelerated MRI Reconstruction, called the Recurrent Variational Network (RecurrentVarNet), by exploiting the properties of Convolutional Recurrent Neural Networks and unrolled algorithms for solving Inverse Problems. The RecurrentVarNet consists of multiple recurrent blocks, each responsible for one iteration of the unrolled variational optimization scheme for solving the inverse problem of multi-coil Accelerated MRI Reconstruction. Contrary to traditional approaches, the optimization steps are performed in the observation domain ($k$-space) instead of the image domain. Each block of the RecurrentVarNet refines the observed $k$-space and comprises a data consistency term and a recurrent unit which takes as input a learned hidden state and the prediction of the previous block. Our proposed method achieves new state of the art qualitative and quantitative reconstruction results on 5-fold and 10-fold accelerated data from a public multi-coil brain dataset, outperforming previous conventional and deep learning-based approaches.

IVAug 17, 2021
Deep MRI Reconstruction with Radial Subsampling

George Yiasemis, Chaoping Zhang, Clara I. Sánchez et al.

In spite of its extensive adaptation in almost every medical diagnostic and examinatorial application, Magnetic Resonance Imaging (MRI) is still a slow imaging modality which limits its use for dynamic imaging. In recent years, Parallel Imaging (PI) and Compressed Sensing (CS) have been utilised to accelerate the MRI acquisition. In clinical settings, subsampling the k-space measurements during scanning time using Cartesian trajectories, such as rectilinear sampling, is currently the most conventional CS approach applied which, however, is prone to producing aliased reconstructions. With the advent of the involvement of Deep Learning (DL) in accelerating the MRI, reconstructing faithful images from subsampled data became increasingly promising. Retrospectively applying a subsampling mask onto the k-space data is a way of simulating the accelerated acquisition of k-space data in real clinical setting. In this paper we compare and provide a review for the effect of applying either rectilinear or radial retrospective subsampling on the quality of the reconstructions outputted by trained deep neural networks. With the same choice of hyper-parameters, we train and evaluate two distinct Recurrent Inference Machines (RIMs), one for each type of subsampling. The qualitative and quantitative results of our experiments indicate that the model trained on data with radial subsampling attains higher performance and learns to estimate reconstructions with higher fidelity paving the way for other DL approaches to involve radial subsampling.

IVNov 10, 2020
Multi-Coil MRI Reconstruction Challenge -- Assessing Brain MRI Reconstruction Models and their Generalizability to Varying Coil Configurations

Youssef Beauferris, Jonas Teuwen, Dimitrios Karkalousos et al.

Deep-learning-based brain magnetic resonance imaging (MRI) reconstruction methods have the potential to accelerate the MRI acquisition process. Nevertheless, the scientific community lacks appropriate benchmarks to assess MRI reconstruction quality of high-resolution brain images, and evaluate how these proposed algorithms will behave in the presence of small, but expected data distribution shifts. The Multi-Coil Magnetic Resonance Image (MC-MRI) Reconstruction Challenge provides a benchmark that aims at addressing these issues, using a large dataset of high-resolution, three-dimensional, T1-weighted MRI scans. The challenge has two primary goals: 1) to compare different MRI reconstruction models on this dataset and 2) to assess the generalizability of these models to data acquired with a different number of receiver coils. In this paper, we describe the challenge experimental design, and summarize the results of a set of baseline and state of the art brain MRI reconstruction models. We provide relevant comparative information on the current MRI reconstruction state-of-the-art and highlight the challenges of obtaining generalizable models that are required prior to broader clinical adoption. The MC-MRI benchmark data, evaluation code and current challenge leaderboard are publicly available. They provide an objective performance assessment for future developments in the field of brain MRI reconstruction.