Guillaume Marie

IV
h-index4
3papers
69citations
Novelty30%
AI Score27

3 Papers

6.1CLJan 29, 2024
LLaMandement: Large Language Models for Summarization of French Legislative Proposals

Joseph Gesnouin, Yannis Tannier, Christophe Gomes Da Silva et al.

This report introduces LLaMandement, a state-of-the-art Large Language Model, fine-tuned by the French government and designed to enhance the efficiency and efficacy of processing parliamentary sessions (including the production of bench memoranda and documents required for interministerial meetings) by generating neutral summaries of legislative proposals. Addressing the administrative challenges of manually processing a growing volume of legislative amendments, LLaMandement stands as a significant legal technological milestone, providing a solution that exceeds the scalability of traditional human efforts while matching the robustness of a specialized legal drafter. We release all our fine-tuned models and training data to the community.

5.1IVMar 22, 2025
Assessing workflow impact and clinical utility of AI-assisted brain aneurysm detection: a multi-reader study

Tommaso Di Noto, Sofyan Jankowski, Francesco Puccinelli et al.

Despite the plethora of AI-based algorithms developed for anomaly detection in radiology, subsequent integration into clinical setting is rarely evaluated. In this work, we assess the applicability and utility of an AI-based model for brain aneurysm detection comparing the performance of two readers with different levels of experience (2 and 13 years). We aim to answer the following questions: 1) Do the readers improve their performance when assisted by the AI algorithm? 2) How much does the AI algorithm impact routine clinical workflow? We reuse and enlarge our open-access, Time-Of-Flight Magnetic Resonance Angiography dataset (N=460). We use 360 subjects for training/validating our algorithm and 100 as unseen test set for the reading session. Even though our model reaches state-of-the-art results on the test set (sensitivity=74%, false positive rate=1.6), we show that neither the junior nor the senior reader significantly increase their sensitivity (p=0.59, p=1, respectively). In addition, we find that reading time for both readers is significantly higher in the "AI-assisted" setting than in the "Unassisted" (+15 seconds, on average; p=3x10^(-4) junior, p=3x10^(-5) senior). The confidence reported by the readers is unchanged across the two settings, indicating that the AI assistance does not influence the certainty of the diagnosis. Our findings highlight the importance of clinical validation of AI algorithms in a clinical setting involving radiologists. This study should serve as a reminder to the community to always examine the real-word effectiveness and workflow impact of proposed algorithms.

12.0IVMar 10, 2021Code
Towards automated brain aneurysm detection in TOF-MRA: open data, weak labels, and anatomical knowledge

Tommaso Di Noto, Guillaume Marie, Sebastien Tourbier et al.

Brain aneurysm detection in Time-Of-Flight Magnetic Resonance Angiography (TOF-MRA) has undergone drastic improvements with the advent of Deep Learning (DL). However, performances of supervised DL models heavily rely on the quantity of labeled samples, which are extremely costly to obtain. Here, we present a DL model for aneurysm detection that overcomes the issue with ''weak'' labels: oversized annotations which are considerably faster to create. Our weak labels resulted to be four times faster to generate than their voxel-wise counterparts. In addition, our model leverages prior anatomical knowledge by focusing only on plausible locations for aneurysm occurrence. We frst train and evaluate our model through cross-validation on an in-house TOF-MRA dataset comprising 284 subjects (170 females / 127 healthy controls / 157 patients with 198 aneurysms). On this dataset, our best model achieved a sensitivity of 83%, with False Positive (FP) rate of 0.8 per patient. To assess model generalizability, we then participated in a challenge for aneurysm detection with TOF-MRA data (93 patients, 20 controls, 125 aneurysms). On the public challenge, sensitivity was 68% (FP rate=2.5), ranking 4th/18 on the open leaderboard. We found no signifcant diference in sensitivity between aneurysm risk-of-rupture groups (p=0.75), locations (p=0.72), or sizes (p=0.15). Data, code and model weights are released under permissive licenses. We demonstrate that weak labels and anatomical knowledge can alleviate the necessity for prohibitively expensive voxel-wise annotations.