Sangwoo Park

RO
h-index13
3papers
42citations
Novelty42%
AI Score21

3 Papers

5.3ROOct 5, 2021
Design of Spiral-Cable Forearm Exoskeleton to Assist Supination for Hemiparetic Stroke Subjects

Ava Chen, Lauren Winterbottom, Katherine O'Reilly et al.

We present the development of a cable-based passive forearm exoskeleton that is designed to assist supination for hemiparetic stroke survivors. Our device uniquely provides torque sufficient for counteracting spasticity within a below-elbow apparatus. The mechanism consists of a spiral single-tendon routing embedded in a rigid forearm brace and terminated at the hand and upper-forearm. A spool with an internal releasable-ratchet mechanism allows the user to manually retract the tendon and rotate the hand to counteract involuntary pronation synergies due to stroke. We characterize the mechanism with benchtop testing and five healthy subjects, and perform a preliminary assessment of the exoskeleton with a single chronic stroke subject having minimal supination ability. The mechanism can be integrated into an existing active hand-opening orthosis to enable supination support during grasping tasks, and also allows for a future actuated supination strategy.

7.3ROOct 5, 2021
Thumb Stabilization and Assistance in a Robotic Hand Orthosis for Post-Stroke Hemiparesis

Ava Chen, Lauren Winterbottom, Sangwoo Park et al.

We propose a dual-cable method of stabilizing the thumb in the context of a hand orthosis designed for individuals with upper extremity hemiparesis after stroke. This cable network adds opposition/reposition capabilities to the thumb, and increases the likelihood of forming a hand pose that can successfully manipulate objects. In addition to a passive-thumb version (where both cables are of fixed length), our approach also allows for a single-actuator active-thumb version (where the extension cable is actuated while the abductor remains passive), which allows a range of motion intended to facilitate creating and maintaining grasps. We performed experiments with five chronic stroke survivors consisting of unimanual resistive-pull tasks and bimanual twisting tasks with simulated real-world objects; these explored the effects of thumb assistance on grasp stability and functional range of motion. Our results show that both active- and passive-thumb versions achieved similar performance in terms of improving grasp force generation over a no-device baseline, but active thumb stabilization enabled users to maintain grasps for longer durations.

6.3ROFeb 16, 2018
Design and Development of Effective Transmission Mechanisms on a Tendon Driven Hand Orthosis for Stroke Patients

Sangwoo Park, Lynne M. Weber, Lauri Bishop et al.

Tendon-driven hand orthoses have advantages over exoskeletons with respect to wearability and safety because of their low-profile design and ability to fit a range of patients without requiring custom joint alignment. However, no existing study on a wearable tendon-driven hand orthosis for stroke patients presents evidence that such devices can overcome spasticity given repeated use and fatigue, or discusses transmission efficiency. In this study, we propose two designs that provide effective force transmission by increasing moment arms around finger joints. We evaluate the designs with geometric models and experiment using a 3D-printed artificial finger to find force and joint angle characteristics of the suggested structures. We also perform clinical tests with stroke patients to demonstrate the feasibility of the designs. The testing supports the hypothesis that the proposed designs efficiently elicit extension of the digits in patients with spasticity as compared to existing baselines.