S. Kevin Zhou

CV
h-index2
8papers
31citations
Novelty57%
AI Score41

8 Papers

2.8CVAug 9, 2023Code
Multi-View Fusion and Distillation for Subgrade Distresses Detection based on 3D-GPR

Chunpeng Zhou, Kangjie Ning, Haishuai Wang et al.

The application of 3D ground-penetrating radar (3D-GPR) for subgrade distress detection has gained widespread popularity. To enhance the efficiency and accuracy of detection, pioneering studies have attempted to adopt automatic detection techniques, particularly deep learning. However, existing works typically rely on traditional 1D A-scan, 2D B-scan or 3D C-scan data of the GPR, resulting in either insufficient spatial information or high computational complexity. To address these challenges, we introduce a novel methodology for the subgrade distress detection task by leveraging the multi-view information from 3D-GPR data. Moreover, we construct a real multi-view image dataset derived from the original 3D-GPR data for the detection task, which provides richer spatial information compared to A-scan and B-scan data, while reducing computational complexity compared to C-scan data. Subsequently, we develop a novel \textbf{M}ulti-\textbf{V}iew \textbf{V}usion and \textbf{D}istillation framework, \textbf{GPR-MVFD}, specifically designed to optimally utilize the multi-view GPR dataset. This framework ingeniously incorporates multi-view distillation and attention-based fusion to facilitate significant feature extraction for subgrade distresses. In addition, a self-adaptive learning mechanism is adopted to stabilize the model training and prevent performance degeneration in each branch. Extensive experiments conducted on this new GPR benchmark demonstrate the effectiveness and efficiency of our proposed framework. Our framework outperforms not only the existing GPR baselines, but also the state-of-the-art methods in the fields of multi-view learning, multi-modal learning, and knowledge distillation. We will release the constructed multi-view GPR dataset with expert-annotated labels and the source codes of the proposed framework.

11.3IVJul 15, 2025Code
U-RWKV: Lightweight medical image segmentation with direction-adaptive RWKV

Hongbo Ye, Fenghe Tang, Peiang Zhao et al.

Achieving equity in healthcare accessibility requires lightweight yet high-performance solutions for medical image segmentation, particularly in resource-limited settings. Existing methods like U-Net and its variants often suffer from limited global Effective Receptive Fields (ERFs), hindering their ability to capture long-range dependencies. To address this, we propose U-RWKV, a novel framework leveraging the Recurrent Weighted Key-Value(RWKV) architecture, which achieves efficient long-range modeling at O(N) computational cost. The framework introduces two key innovations: the Direction-Adaptive RWKV Module(DARM) and the Stage-Adaptive Squeeze-and-Excitation Module(SASE). DARM employs Dual-RWKV and QuadScan mechanisms to aggregate contextual cues across images, mitigating directional bias while preserving global context and maintaining high computational efficiency. SASE dynamically adapts its architecture to different feature extraction stages, balancing high-resolution detail preservation and semantic relationship capture. Experiments demonstrate that U-RWKV achieves state-of-the-art segmentation performance with high computational efficiency, offering a practical solution for democratizing advanced medical imaging technologies in resource-constrained environments. The code is available at https://github.com/hbyecoding/U-RWKV.

3.7CVDec 9, 2024Code
HYATT-Net is Grand: A Hybrid Attention Network for Performant Anatomical Landmark Detection

Xiaoqian Zhou, Zhen Huang, Heqin Zhu et al.

Anatomical landmark detection (ALD) from a medical image is crucial for a wide array of clinical applications. While existing methods achieve quite some success in ALD, they often struggle to balance global context with computational efficiency, particularly with high-resolution images, thereby leading to the rise of a natural question: where is the performance limit of ALD? In this paper, we aim to forge performant ALD by proposing a {\bf HY}brid {\bf ATT}ention {\bf Net}work (HYATT-Net) with the following designs: (i) A novel hybrid architecture that integrates CNNs and Transformers. Its core is the BiFormer module, utilizing Bi-Level Routing Attention for efficient attention to relevant image regions. This, combined with Attention Residual Module(ARM), enables precise local feature refinement guided by the global context. (ii) A Feature Fusion Correction Module that aggregates multi-scale features and thus mitigates a resolution loss. Deep supervision with a mean-square error loss on multi-resolution heatmaps optimizes the model. Experiments on five diverse datasets demonstrate state-of-the-art performance, surpassing existing methods in accuracy, robustness, and efficiency. The HYATT-Net provides a promising solution for accurate and efficient ALD in complex medical images. Our codes and data are already released at: \url{https://github.com/ECNUACRush/HYATT-Net}.

2.2ROMar 22, 2024
Infrastructure-Assisted Collaborative Perception in Automated Valet Parking: A Safety Perspective

Yukuan Jia, Jiawen Zhang, Shimeng Lu et al.

Environmental perception in Automated Valet Parking (AVP) has been a challenging task due to severe occlusions in parking garages. Although Collaborative Perception (CP) can be applied to broaden the field of view of connected vehicles, the limited bandwidth of vehicular communications restricts its application. In this work, we propose a BEV feature-based CP network architecture for infrastructure-assisted AVP systems. The model takes the roadside camera and LiDAR as optional inputs and adaptively fuses them with onboard sensors in a unified BEV representation. Autoencoder and downsampling are applied for channel-wise and spatial-wise dimension reduction, while sparsification and quantization further compress the feature map with little loss in data precision. Combining these techniques, the size of a BEV feature map is effectively compressed to fit in the feasible data rate of the NR-V2X network. With the synthetic AVP dataset, we observe that CP can effectively increase perception performance, especially for pedestrians. Moreover, the advantage of infrastructure-assisted CP is demonstrated in two typical safety-critical scenarios in the AVP setting, increasing the maximum safe cruising speed by up to 3m/s in both scenarios.

8.6IVJun 24, 2025Code
NeRF-based CBCT Reconstruction needs Normalization and Initialization

Zhuowei Xu, Han Li, Dai Sun et al.

Cone Beam Computed Tomography (CBCT) is widely used in medical imaging. However, the limited number and intensity of X-ray projections make reconstruction an ill-posed problem with severe artifacts. NeRF-based methods have achieved great success in this task. However, they suffer from a local-global training mismatch between their two key components: the hash encoder and the neural network. Specifically, in each training step, only a subset of the hash encoder's parameters is used (local sparse), whereas all parameters in the neural network participate (global dense). Consequently, hash features generated in each step are highly misaligned, as they come from different subsets of the hash encoder. These misalignments from different training steps are then fed into the neural network, causing repeated inconsistent global updates in training, which leads to unstable training, slower convergence, and degraded reconstruction quality. Aiming to alleviate the impact of this local-global optimization mismatch, we introduce a Normalized Hash Encoder, which enhances feature consistency and mitigates the mismatch. Additionally, we propose a Mapping Consistency Initialization(MCI) strategy that initializes the neural network before training by leveraging the global mapping property from a well-trained model. The initialized neural network exhibits improved stability during early training, enabling faster convergence and enhanced reconstruction performance. Our method is simple yet effective, requiring only a few lines of code while substantially improving training efficiency on 128 CT cases collected from 4 different datasets, covering 7 distinct anatomical regions.

3.6CVMar 20, 2025
Landmarks Are Alike Yet Distinct: Harnessing Similarity and Individuality for One-Shot Medical Landmark Detection

Xu He, Zhen Huang, Qingsong Yao et al.

Landmark detection plays a crucial role in medical imaging applications such as disease diagnosis, bone age estimation, and therapy planning. However, training models for detecting multiple landmarks simultaneously often encounters the "seesaw phenomenon", where improvements in detecting certain landmarks lead to declines in detecting others. Yet, training a separate model for each landmark increases memory usage and computational overhead. To address these challenges, we propose a novel approach based on the belief that "landmarks are distinct" by training models with pseudo-labels and template data updated continuously during the training process, where each model is dedicated to detecting a single landmark to achieve high accuracy. Furthermore, grounded on the belief that "landmarks are also alike", we introduce an adapter-based fusion model, combining shared weights with landmark-specific weights, to efficiently share model parameters while allowing flexible adaptation to individual landmarks. This approach not only significantly reduces memory and computational resource requirements but also effectively mitigates the seesaw phenomenon in multi-landmark training. Experimental results on publicly available medical image datasets demonstrate that the single-landmark models significantly outperform traditional multi-point joint training models in detecting individual landmarks. Although our adapter-based fusion model shows slightly lower performance compared to the combined results of all single-landmark models, it still surpasses the current state-of-the-art methods while achieving a notable improvement in resource efficiency.

3.3ARMay 6, 2024
DeltaKWS: A 65nm 36nJ/Decision Bio-inspired Temporal-Sparsity-Aware Digital Keyword Spotting IC with 0.6V Near-Threshold SRAM

Qinyu Chen, Kwantae Kim, Chang Gao et al.

This paper introduces DeltaKWS, to the best of our knowledge, the first $Δ$RNN-enabled fine-grained temporal sparsity-aware KWS IC for voice-controlled devices. The 65 nm prototype chip features a number of techniques to enhance performance, area, and power efficiencies, specifically: 1) a bio-inspired delta-gated recurrent neural network ($Δ$RNN) classifier leveraging temporal similarities between neighboring feature vectors extracted from input frames and network hidden states, eliminating unnecessary operations and memory accesses; 2) an IIR BPF-based FEx that leverages mixed-precision quantization, low-cost computing structure and channel selection; 3) a 24 kB 0.6 V near-$V_\text{TH}$ weight SRAM that achieves 6.6X lower read power than the foundry-provided SRAM. From chip measurement results, we show that the DeltaKWS achieves an 11/12-class GSCD accuracy of 90.5%/89.5% respectively and energy consumption of 36 nJ/decision in 65 nm CMOS process. At 87% temporal sparsity, computing latency and energy/inference are reduced by 2.4X/3.4X, respectively. The IIR BPF-based FEx, $Δ$RNN accelerator, and 24 kB near-$V_\text{TH}$ SRAM blocks occupy 0.084 mm$^{2}$, 0.319 mm$^{2}$, and 0.381 mm$^{2}$ respectively (0.78 mm$^{2}$ in total).

10.4IVMay 7, 2023
PELE scores: Pelvic X-ray Landmark Detection by Pelvis Extraction and Enhancement

Zhen Huang, Han Li, Shitong Shao et al.

The pelvis, the lower part of the trunk, supports and balances the trunk. Landmark detection from a pelvic X-ray (PXR) facilitates downstream analysis and computer-assisted diagnosis and treatment of pelvic diseases. Although PXRs have the advantages of low radiation and reduced cost compared to computed tomography (CT) images, their 2D pelvis-tissue superposition of 3D structures confuses clinical decision-making. In this paper, we propose a PELvis Extraction (PELE) module that utilizes 3D prior anatomical knowledge in CT to guide and well isolate the pelvis from PXRs, thereby eliminating the influence of soft tissue. We conduct an extensive evaluation based on two public datasets and one private dataset, totaling 850 PXRs. The experimental results show that the proposed PELE module significantly improves the accuracy of PXRs landmark detection and achieves state-of-the-art performances in several benchmark metrics, thus better serving downstream tasks.