SurgT challenge: Benchmark of Soft-Tissue Trackers for Robotic SurgeryJoao Cartucho, Alistair Weld, Samyakh Tukra et al.
This paper introduces the ``SurgT: Surgical Tracking" challenge which was organised in conjunction with MICCAI 2022. There were two purposes for the creation of this challenge: (1) the establishment of the first standardised benchmark for the research community to assess soft-tissue trackers; and (2) to encourage the development of unsupervised deep learning methods, given the lack of annotated data in surgery. A dataset of 157 stereo endoscopic videos from 20 clinical cases, along with stereo camera calibration parameters, have been provided. Participants were assigned the task of developing algorithms to track the movement of soft tissues, represented by bounding boxes, in stereo endoscopic videos. At the end of the challenge, the developed methods were assessed on a previously hidden test subset. This assessment uses benchmarking metrics that were purposely developed for this challenge, to verify the efficacy of unsupervised deep learning algorithms in tracking soft-tissue. The metric used for ranking the methods was the Expected Average Overlap (EAO) score, which measures the average overlap between a tracker's and the ground truth bounding boxes. Coming first in the challenge was the deep learning submission by ICVS-2Ai with a superior EAO score of 0.617. This method employs ARFlow to estimate unsupervised dense optical flow from cropped images, using photometric and regularization losses. Second, Jmees with an EAO of 0.583, uses deep learning for surgical tool segmentation on top of a non-deep learning baseline method: CSRT. CSRT by itself scores a similar EAO of 0.563. The results from this challenge show that currently, non-deep learning methods are still competitive. The dataset and benchmarking tool created for this challenge have been made publicly available at https://surgt.grand-challenge.org/.
1.5CVFeb 19
Cholec80-port: A Geometrically Consistent Trocar Port Segmentation Dataset for Robust Surgical Scene UnderstandingShunsuke Kikuchi, Atsushi Kouno, Hiroki Matsuzaki
Trocar ports are camera-fixed, pseudo-static structures that can persistently occlude laparoscopic views and attract disproportionate feature points due to specular, textured surfaces. This makes ports particularly detrimental to geometry-based downstream pipelines such as image stitching, 3D reconstruction, and visual SLAM, where dynamic or non-anatomical outliers degrade alignment and tracking stability. Despite this practical importance, explicit port labels are rare in public surgical datasets, and existing annotations often violate geometric consistency by masking the central lumen (opening), even when anatomical regions are visible through it. We present Cholec80-port, a high-fidelity trocar port segmentation dataset derived from Cholec80, together with a rigorous standard operating procedure (SOP) that defines a port-sleeve mask excluding the central opening. We additionally cleanse and unify existing public datasets under the same SOP. Experiments demonstrate that geometrically consistent annotations substantially improve cross-dataset robustness beyond what dataset size alone provides.
8.7LGFeb 11, 2022
PEg TRAnsfer Workflow recognition challenge report: Does multi-modal data improve recognition?Arnaud Huaulmé, Kanako Harada, Quang-Minh Nguyen et al.
This paper presents the design and results of the "PEg TRAnsfert Workflow recognition" (PETRAW) challenge whose objective was to develop surgical workflow recognition methods based on one or several modalities, among video, kinematic, and segmentation data, in order to study their added value. The PETRAW challenge provided a data set of 150 peg transfer sequences performed on a virtual simulator. This data set was composed of videos, kinematics, semantic segmentation, and workflow annotations which described the sequences at three different granularity levels: phase, step, and activity. Five tasks were proposed to the participants: three of them were related to the recognition of all granularities with one of the available modalities, while the others addressed the recognition with a combination of modalities. Average application-dependent balanced accuracy (AD-Accuracy) was used as evaluation metric to take unbalanced classes into account and because it is more clinically relevant than a frame-by-frame score. Seven teams participated in at least one task and four of them in all tasks. Best results are obtained with the use of the video and the kinematics data with an AD-Accuracy between 93% and 90% for the four teams who participated in all tasks. The improvement between video/kinematic-based methods and the uni-modality ones was significant for all of the teams. However, the difference in testing execution time between the video/kinematic-based and the kinematic-based methods has to be taken into consideration. Is it relevant to spend 20 to 200 times more computing time for less than 3% of improvement? The PETRAW data set is publicly available at www.synapse.org/PETRAW to encourage further research in surgical workflow recognition.