CLJul 22, 2024
RadioRAG: Online Retrieval-augmented Generation for Radiology Question AnsweringSoroosh Tayebi Arasteh, Mahshad Lotfinia, Keno Bressem et al.
Large language models (LLMs) often generate outdated or inaccurate information based on static training datasets. Retrieval-augmented generation (RAG) mitigates this by integrating outside data sources. While previous RAG systems used pre-assembled, fixed databases with limited flexibility, we have developed Radiology RAG (RadioRAG), an end-to-end framework that retrieves data from authoritative radiologic online sources in real-time. We evaluate the diagnostic accuracy of various LLMs when answering radiology-specific questions with and without access to additional online information via RAG. Using 80 questions from the RSNA Case Collection across radiologic subspecialties and 24 additional expert-curated questions with reference standard answers, LLMs (GPT-3.5-turbo, GPT-4, Mistral-7B, Mixtral-8x7B, and Llama3 [8B and 70B]) were prompted with and without RadioRAG in a zero-shot inference scenario RadioRAG retrieved context-specific information from Radiopaedia in real-time. Accuracy was investigated. Statistical analyses were performed using bootstrapping. The results were further compared with human performance. RadioRAG improved diagnostic accuracy across most LLMs, with relative accuracy increases ranging up to 54% for different LLMs. It matched or exceeded non-RAG models and the human radiologist in question answering across radiologic subspecialties, particularly in breast imaging and emergency radiology. However, the degree of improvement varied among models; GPT-3.5-turbo and Mixtral-8x7B-instruct-v0.1 saw notable gains, while Mistral-7B-instruct-v0.2 showed no improvement, highlighting variability in RadioRAG's effectiveness. LLMs benefit when provided access to domain-specific data beyond their training data. RadioRAG shows potential to improve LLM accuracy and factuality in radiology question answering by integrating real-time domain-specific data.
CVSep 29, 2023
Reconstruction of Patient-Specific Confounders in AI-based Radiologic Image Interpretation using Generative PretrainingTianyu Han, Laura Žigutytė, Luisa Huck et al.
Detecting misleading patterns in automated diagnostic assistance systems, such as those powered by Artificial Intelligence, is critical to ensuring their reliability, particularly in healthcare. Current techniques for evaluating deep learning models cannot visualize confounding factors at a diagnostic level. Here, we propose a self-conditioned diffusion model termed DiffChest and train it on a dataset of 515,704 chest radiographs from 194,956 patients from multiple healthcare centers in the United States and Europe. DiffChest explains classifications on a patient-specific level and visualizes the confounding factors that may mislead the model. We found high inter-reader agreement when evaluating DiffChest's capability to identify treatment-related confounders, with Fleiss' Kappa values of 0.8 or higher across most imaging findings. Confounders were accurately captured with 11.1% to 100% prevalence rates. Furthermore, our pretraining process optimized the model to capture the most relevant information from the input radiographs. DiffChest achieved excellent diagnostic accuracy when diagnosing 11 chest conditions, such as pleural effusion and cardiac insufficiency, and at least sufficient diagnostic accuracy for the remaining conditions. Our findings highlight the potential of pretraining based on diffusion models in medical image classification, specifically in providing insights into confounding factors and model robustness.
IVNov 24, 2024
Medical Slice Transformer: Improved Diagnosis and Explainability on 3D Medical Images with DINOv2Gustav Müller-Franzes, Firas Khader, Robert Siepmann et al.
MRI and CT are essential clinical cross-sectional imaging techniques for diagnosing complex conditions. However, large 3D datasets with annotations for deep learning are scarce. While methods like DINOv2 are encouraging for 2D image analysis, these methods have not been applied to 3D medical images. Furthermore, deep learning models often lack explainability due to their "black-box" nature. This study aims to extend 2D self-supervised models, specifically DINOv2, to 3D medical imaging while evaluating their potential for explainable outcomes. We introduce the Medical Slice Transformer (MST) framework to adapt 2D self-supervised models for 3D medical image analysis. MST combines a Transformer architecture with a 2D feature extractor, i.e., DINOv2. We evaluate its diagnostic performance against a 3D convolutional neural network (3D ResNet) across three clinical datasets: breast MRI (651 patients), chest CT (722 patients), and knee MRI (1199 patients). Both methods were tested for diagnosing breast cancer, predicting lung nodule dignity, and detecting meniscus tears. Diagnostic performance was assessed by calculating the Area Under the Receiver Operating Characteristic Curve (AUC). Explainability was evaluated through a radiologist's qualitative comparison of saliency maps based on slice and lesion correctness. P-values were calculated using Delong's test. MST achieved higher AUC values compared to ResNet across all three datasets: breast (0.94$\pm$0.01 vs. 0.91$\pm$0.02, P=0.02), chest (0.95$\pm$0.01 vs. 0.92$\pm$0.02, P=0.13), and knee (0.85$\pm$0.04 vs. 0.69$\pm$0.05, P=0.001). Saliency maps were consistently more precise and anatomically correct for MST than for ResNet. Self-supervised 2D models like DINOv2 can be effectively adapted for 3D medical imaging using MST, offering enhanced diagnostic accuracy and explainability compared to convolutional neural networks.
CVOct 10, 2025
Hallucination Filtering in Radiology Vision-Language Models Using Discrete Semantic EntropyPatrick Wienholt, Sophie Caselitz, Robert Siepmann et al.
To determine whether using discrete semantic entropy (DSE) to reject questions likely to generate hallucinations can improve the accuracy of black-box vision-language models (VLMs) in radiologic image based visual question answering (VQA). This retrospective study evaluated DSE using two publicly available, de-identified datasets: (i) the VQA-Med 2019 benchmark (500 images with clinical questions and short-text answers) and (ii) a diagnostic radiology dataset (206 cases: 60 computed tomography scans, 60 magnetic resonance images, 60 radiographs, 26 angiograms) with corresponding ground-truth diagnoses. GPT-4o and GPT-4.1 answered each question 15 times using a temperature of 1.0. Baseline accuracy was determined using low-temperature answers (temperature 0.1). Meaning-equivalent responses were grouped using bidirectional entailment checks, and DSE was computed from the relative frequencies of the resulting semantic clusters. Accuracy was recalculated after excluding questions with DSE > 0.6 or > 0.3. p-values and 95% confidence intervals were obtained using bootstrap resampling and a Bonferroni-corrected threshold of p < .004 for statistical significance. Across 706 image-question pairs, baseline accuracy was 51.7% for GPT-4o and 54.8% for GPT-4.1. After filtering out high-entropy questions (DSE > 0.3), accuracy on the remaining questions was 76.3% (retained questions: 334/706) for GPT-4o and 63.8% (retained questions: 499/706) for GPT-4.1 (both p < .001). Accuracy gains were observed across both datasets and largely remained statistically significant after Bonferroni correction. DSE enables reliable hallucination detection in black-box VLMs by quantifying semantic inconsistency. This method significantly improves diagnostic answer accuracy and offers a filtering strategy for clinical VLM applications.
CVOct 17, 2025
Effect of Reporting Mode and Clinical Experience on Radiologists' Gaze and Image Analysis Behavior in Chest RadiographyMahta Khoobi, Marc Sebastian von der Stueck, Felix Barajas Ordonez et al.
Structured reporting (SR) and artificial intelligence (AI) may transform how radiologists interact with imaging studies. This prospective study (July to December 2024) evaluated the impact of three reporting modes: free-text (FT), structured reporting (SR), and AI-assisted structured reporting (AI-SR), on image analysis behavior, diagnostic accuracy, efficiency, and user experience. Four novice and four non-novice readers (radiologists and medical students) each analyzed 35 bedside chest radiographs per session using a customized viewer and an eye-tracking system. Outcomes included diagnostic accuracy (compared with expert consensus using Cohen's $κ$), reporting time per radiograph, eye-tracking metrics, and questionnaire-based user experience. Statistical analysis used generalized linear mixed models with Bonferroni post-hoc tests with a significance level of ($P \le .01$). Diagnostic accuracy was similar in FT ($κ= 0.58$) and SR ($κ= 0.60$) but higher in AI-SR ($κ= 0.71$, $P < .001$). Reporting times decreased from $88 \pm 38$ s (FT) to $37 \pm 18$ s (SR) and $25 \pm 9$ s (AI-SR) ($P < .001$). Saccade counts for the radiograph field ($205 \pm 135$ (FT), $123 \pm 88$ (SR), $97 \pm 58$ (AI-SR)) and total fixation duration for the report field ($11 \pm 5$ s (FT), $5 \pm 3$ s (SR), $4 \pm 1$ s (AI-SR)) were lower with SR and AI-SR ($P < .001$ each). Novice readers shifted gaze towards the radiograph in SR, while non-novice readers maintained their focus on the radiograph. AI-SR was the preferred mode. In conclusion, SR improves efficiency by guiding visual attention toward the image, and AI-prefilled SR further enhances diagnostic accuracy and user satisfaction.
IVJun 13, 2025
Enhancing Privacy: The Utility of Stand-Alone Synthetic CT and MRI for Tumor and Bone SegmentationAndré Ferreira, Kunpeng Xie, Caroline Wilpert et al.
AI requires extensive datasets, while medical data is subject to high data protection. Anonymization is essential, but poses a challenge for some regions, such as the head, as identifying structures overlap with regions of clinical interest. Synthetic data offers a potential solution, but studies often lack rigorous evaluation of realism and utility. Therefore, we investigate to what extent synthetic data can replace real data in segmentation tasks. We employed head and neck cancer CT scans and brain glioma MRI scans from two large datasets. Synthetic data were generated using generative adversarial networks and diffusion models. We evaluated the quality of the synthetic data using MAE, MS-SSIM, Radiomics and a Visual Turing Test (VTT) performed by 5 radiologists and their usefulness in segmentation tasks using DSC. Radiomics indicates high fidelity of synthetic MRIs, but fall short in producing highly realistic CT tissue, with correlation coefficient of 0.8784 and 0.5461 for MRI and CT tumors, respectively. DSC results indicate limited utility of synthetic data: tumor segmentation achieved DSC=0.064 on CT and 0.834 on MRI, while bone segmentation a mean DSC=0.841. Relation between DSC and correlation is observed, but is limited by the complexity of the task. VTT results show synthetic CTs' utility, but with limited educational applications. Synthetic data can be used independently for the segmentation task, although limited by the complexity of the structures to segment. Advancing generative models to better tolerate heterogeneous inputs and learn subtle details is essential for enhancing their realism and expanding their application potential.