Lidar with Velocity: Correcting Moving Objects Point Cloud Distortion from Oscillating Scanning Lidars by Fusion with CameraWen Yang, Zheng Gong, Baifu Huang et al.
Lidar point cloud distortion from moving object is an important problem in autonomous driving, and recently becomes even more demanding with the emerging of newer lidars, which feature back-and-forth scanning patterns. Accurately estimating moving object velocity would not only provide a tracking capability but also correct the point cloud distortion with more accurate description of the moving object. Since lidar measures the time-of-flight distance but with a sparse angular resolution, the measurement is precise in the radial measurement but lacks angularly. Camera on the other hand provides a dense angular resolution. In this paper, Gaussian-based lidar and camera fusion is proposed to estimate the full velocity and correct the lidar distortion. A probabilistic Kalman-filter framework is provided to track the moving objects, estimate their velocities and simultaneously correct the point clouds distortions. The framework is evaluated on real road data and the fusion method outperforms the traditional ICP-based and point-cloud only method. The complete working framework is open-sourced (https://github.com/ISEE-Technology/lidar-with-velocity) to accelerate the adoption of the emerging lidars.
6.3IVNov 19, 2024
Acquire Precise and Comparable Fundus Image Quality Score: FTHNet and FQS DatasetZheng Gong, Zhuo Deng, Run Gan et al.
The retinal fundus images are utilized extensively in the diagnosis, and their quality can directly affect the diagnosis results. However, due to the insufficient dataset and algorithm application, current fundus image quality assessment (FIQA) methods are not powerful enough to meet ophthalmologists` demands. In this paper, we address the limitations of datasets and algorithms in FIQA. First, we establish a new FIQA dataset, Fundus Quality Score(FQS), which includes 2246 fundus images with two labels: a continuous Mean Opinion Score varying from 0 to 100 and a three-level quality label. Then, we propose a FIQA Transformer-based Hypernetwork (FTHNet) to solve these tasks with regression results rather than classification results in conventional FIQA works. The FTHNet is optimized for the FIQA tasks with extensive experiments. Results on our FQS dataset show that the FTHNet can give quality scores for fundus images with PLCC of 0.9423 and SRCC of 0.9488, significantly outperforming other methods with fewer parameters and less computation complexity.We successfully build a dataset and model addressing the problems of current FIQA methods. Furthermore, the model deployment experiments demonstrate its potential in automatic medical image quality control. All experiments are carried out with 10-fold cross-validation to ensure the significance of the results.