Leveraging Cross-Lingual Transfer Learning in Spoken Named Entity Recognition SystemsMoncef Benaicha, David Thulke, M. A. Tuğtekin Turan
Recent Named Entity Recognition (NER) advancements have significantly enhanced text classification capabilities. This paper focuses on spoken NER, aimed explicitly at spoken document retrieval, an area not widely studied due to the lack of comprehensive datasets for spoken contexts. Additionally, the potential for cross-lingual transfer learning in low-resource situations deserves further investigation. In our study, we applied transfer learning techniques across Dutch, English, and German using both pipeline and End-to-End (E2E) approaches. We employed Wav2Vec2 XLS-R models on custom pseudo-annotated datasets to evaluate the adaptability of cross-lingual systems. Our exploration of different architectural configurations assessed the robustness of these systems in spoken NER. Results showed that the E2E model was superior to the pipeline model, particularly with limited annotation resources. Furthermore, transfer learning from German to Dutch improved performance by 7% over the standalone Dutch E2E system and 4% over the Dutch pipeline model. Our findings highlight the effectiveness of cross-lingual transfer in spoken NER and emphasize the need for additional data collection to improve these systems.
13.6CVNov 22, 2019
SelfVIO: Self-Supervised Deep Monocular Visual-Inertial Odometry and Depth EstimationYasin Almalioglu, Mehmet Turan, Alp Eren Sari et al.
In the last decade, numerous supervised deep learning approaches requiring large amounts of labeled data have been proposed for visual-inertial odometry (VIO) and depth map estimation. To overcome the data limitation, self-supervised learning has emerged as a promising alternative, exploiting constraints such as geometric and photometric consistency in the scene. In this study, we introduce a novel self-supervised deep learning-based VIO and depth map recovery approach (SelfVIO) using adversarial training and self-adaptive visual-inertial sensor fusion. SelfVIO learns to jointly estimate 6 degrees-of-freedom (6-DoF) ego-motion and a depth map of the scene from unlabeled monocular RGB image sequences and inertial measurement unit (IMU) readings. The proposed approach is able to perform VIO without the need for IMU intrinsic parameters and/or the extrinsic calibration between the IMU and the camera. estimation and single-view depth recovery network. We provide comprehensive quantitative and qualitative evaluations of the proposed framework comparing its performance with state-of-the-art VIO, VO, and visual simultaneous localization and mapping (VSLAM) approaches on the KITTI, EuRoC and Cityscapes datasets. Detailed comparisons prove that SelfVIO outperforms state-of-the-art VIO approaches in terms of pose estimation and depth recovery, making it a promising approach among existing methods in the literature.
11.5ROMar 2, 2018
Magnetic-Visual Sensor Fusion-based Dense 3D Reconstruction and Localization for Endoscopic Capsule RobotsMehmet Turan, Yasin Almalioglu, Evin Pinar Ornek et al.
Reliable and real-time 3D reconstruction and localization functionality is a crucial prerequisite for the navigation of actively controlled capsule endoscopic robots as an emerging, minimally invasive diagnostic and therapeutic technology for use in the gastrointestinal (GI) tract. In this study, we propose a fully dense, non-rigidly deformable, strictly real-time, intraoperative map fusion approach for actively controlled endoscopic capsule robot applications which combines magnetic and vision-based localization, with non-rigid deformations based frame-to-model map fusion. The performance of the proposed method is demonstrated using four different ex-vivo porcine stomach models. Across different trajectories of varying speed and complexity, and four different endoscopic cameras, the root mean square surface reconstruction errors 1.58 to 2.17 cm.
13.8ROSep 8, 2017
EndoSensorFusion: Particle Filtering-Based Multi-sensory Data Fusion with Switching State-Space Model for Endoscopic Capsule RobotsMehmet Turan, Yasin Almalioglu, Hunter Gilbert et al.
A reliable, real time multi-sensor fusion functionality is crucial for localization of actively controlled capsule endoscopy robots, which are an emerging, minimally invasive diagnostic and therapeutic technology for the gastrointestinal (GI) tract. In this study, we propose a novel multi-sensor fusion approach based on a particle filter that incorporates an online estimation of sensor reliability and a non-linear kinematic model learned by a recurrent neural network. Our method sequentially estimates the true robot pose from noisy pose observations delivered by multiple sensors. We experimentally test the method using 5 degree-of-freedom (5-DoF) absolute pose measurement by a magnetic localization system and a 6-DoF relative pose measurement by visual odometry. In addition, the proposed method is capable of detecting and handling sensor failures by ignoring corrupted data, providing the robustness expected of a medical device. Detailed analyses and evaluations are presented using ex-vivo experiments on a porcine stomach model prove that our system achieves high translational and rotational accuracies for different types of endoscopic capsule robot trajectories.