Jiahao Huang

IV
h-index7
17papers
405citations
Novelty49%
AI Score39

17 Papers

15.7IVJun 25, 2023Code
CDiffMR: Can We Replace the Gaussian Noise with K-Space Undersampling for Fast MRI?

Jiahao Huang, Angelica Aviles-Rivero, Carola-Bibiane Schönlieb et al.

Deep learning has shown the capability to substantially accelerate MRI reconstruction while acquiring fewer measurements. Recently, diffusion models have gained burgeoning interests as a novel group of deep learning-based generative methods. These methods seek to sample data points that belong to a target distribution from a Gaussian distribution, which has been successfully extended to MRI reconstruction. In this work, we proposed a Cold Diffusion-based MRI reconstruction method called CDiffMR. Different from conventional diffusion models, the degradation operation of our CDiffMR is based on \textit{k}-space undersampling instead of adding Gaussian noise, and the restoration network is trained to harness a de-aliaseing function. We also design starting point and data consistency conditioning strategies to guide and accelerate the reverse process. More intriguingly, the pre-trained CDiffMR model can be reused for reconstruction tasks with different undersampling rates. We demonstrated, through extensive numerical and visual experiments, that the proposed CDiffMR can achieve comparable or even superior reconstruction results than state-of-the-art models. Compared to the diffusion model-based counterpart, CDiffMR reaches readily competing results using only $1.6 \sim 3.4\%$ for inference time. The code is publicly available at https://github.com/ayanglab/CDiffMR.

12.2CVJul 5, 2022Code
Swin Deformable Attention U-Net Transformer (SDAUT) for Explainable Fast MRI

Jiahao Huang, Xiaodan Xing, Zhifan Gao et al.

Fast MRI aims to reconstruct a high fidelity image from partially observed measurements. Exuberant development in fast MRI using deep learning has been witnessed recently. Meanwhile, novel deep learning paradigms, e.g., Transformer based models, are fast-growing in natural language processing and promptly developed for computer vision and medical image analysis due to their prominent performance. Nevertheless, due to the complexity of the Transformer, the application of fast MRI may not be straightforward. The main obstacle is the computational cost of the self-attention layer, which is the core part of the Transformer, can be expensive for high resolution MRI inputs. In this study, we propose a new Transformer architecture for solving fast MRI that coupled Shifted Windows Transformer with U-Net to reduce the network complexity. We incorporate deformable attention to construe the explainability of our reconstruction model. We empirically demonstrate that our method achieves consistently superior performance on the fast MRI task. Besides, compared to state-of-the-art Transformer models, our method has fewer network parameters while revealing explainability. The code is publicly available at https://github.com/ayanglab/SDAUT.

5.1MED-PHMar 31, 2023
Deep Learning-based Diffusion Tensor Cardiac Magnetic Resonance Reconstruction: A Comparison Study

Jiahao Huang, Pedro F. Ferreira, Lichao Wang et al.

In vivo cardiac diffusion tensor imaging (cDTI) is a promising Magnetic Resonance Imaging (MRI) technique for evaluating the micro-structure of myocardial tissue in the living heart, providing insights into cardiac function and enabling the development of innovative therapeutic strategies. However, the integration of cDTI into routine clinical practice is challenging due to the technical obstacles involved in the acquisition, such as low signal-to-noise ratio and long scanning times. In this paper, we investigate and implement three different types of deep learning-based MRI reconstruction models for cDTI reconstruction. We evaluate the performance of these models based on reconstruction quality assessment and diffusion tensor parameter assessment. Our results indicate that the models we discussed in this study can be applied for clinical use at an acceleration factor (AF) of $\times 2$ and $\times 4$, with the D5C5 model showing superior fidelity for reconstruction and the SwinMR model providing higher perceptual scores. There is no statistical difference with the reference for all diffusion tensor parameters at AF $\times 2$ or most DT parameters at AF $\times 4$, and the quality of most diffusion tensor parameter maps are visually acceptable. SwinMR is recommended as the optimal approach for reconstruction at AF $\times 2$ and AF $\times 4$. However, we believed the models discussed in this studies are not prepared for clinical use at a higher AF. At AF $\times 8$, the performance of all models discussed remains limited, with only half of the diffusion tensor parameters being recovered to a level with no statistical difference from the reference. Some diffusion tensor parameter maps even provide wrong and misleading information.

6.6IVApr 1, 2022
Data and Physics Driven Learning Models for Fast MRI -- Fundamentals and Methodologies from CNN, GAN to Attention and Transformers

Jiahao Huang, Yingying Fang, Yang Nan et al.

Research studies have shown no qualms about using data driven deep learning models for downstream tasks in medical image analysis, e.g., anatomy segmentation and lesion detection, disease diagnosis and prognosis, and treatment planning. However, deep learning models are not the sovereign remedy for medical image analysis when the upstream imaging is not being conducted properly (with artefacts). This has been manifested in MRI studies, where the scanning is typically slow, prone to motion artefacts, with a relatively low signal to noise ratio, and poor spatial and/or temporal resolution. Recent studies have witnessed substantial growth in the development of deep learning techniques for propelling fast MRI. This article aims to (1) introduce the deep learning based data driven techniques for fast MRI including convolutional neural network and generative adversarial network based methods, (2) survey the attention and transformer based models for speeding up MRI reconstruction, and (3) detail the research in coupling physics and data driven models for MRI acceleration. Finally, we will demonstrate through a few clinical applications, explain the importance of data harmonisation and explainable models for such fast MRI techniques in multicentre and multi-scanner studies, and discuss common pitfalls in current research and recommendations for future research directions.

3.0IVSep 27, 2023
Style Transfer and Self-Supervised Learning Powered Myocardium Infarction Super-Resolution Segmentation

Lichao Wang, Jiahao Huang, Xiaodan Xing et al.

This study proposes a pipeline that incorporates a novel style transfer model and a simultaneous super-resolution and segmentation model. The proposed pipeline aims to enhance diffusion tensor imaging (DTI) images by translating them into the late gadolinium enhancement (LGE) domain, which offers a larger amount of data with high-resolution and distinct highlighting of myocardium infarction (MI) areas. Subsequently, the segmentation task is performed on the LGE style image. An end-to-end super-resolution segmentation model is introduced to generate high-resolution mask from low-resolution LGE style DTI image. Further, to enhance the performance of the model, a multi-task self-supervised learning strategy is employed to pre-train the super-resolution segmentation model, allowing it to acquire more representative knowledge and improve its segmentation performance after fine-tuning. https: github.com/wlc2424762917/Med_Img

11.7IVJan 23, 2023
ViGU: Vision GNN U-Net for Fast MRI

Jiahao Huang, Angelica Aviles-Rivero, Carola-Bibiane Schonlieb et al.

Deep learning models have been widely applied for fast MRI. The majority of existing deep learning models, e.g., convolutional neural networks, work on data with Euclidean or regular grids structures. However, high-dimensional features extracted from MR data could be encapsulated in non-Euclidean manifolds. This disparity between the go-to assumption of existing models and data requirements limits the flexibility to capture irregular anatomical features in MR data. In this work, we introduce a novel Vision GNN type network for fast MRI called Vision GNN U-Net (ViGU). More precisely, the pixel array is first embedded into patches and then converted into a graph. Secondly, a U-shape network is developed using several graph blocks in symmetrical encoder and decoder paths. Moreover, we show that the proposed ViGU can also benefit from Generative Adversarial Networks yielding to its variant ViGU-GAN. We demonstrate, through numerical and visual experiments, that the proposed ViGU and GAN variant outperform existing CNN and GAN-based methods. Moreover, we show that the proposed network readily competes with approaches based on Transformers while requiring a fraction of the computational cost. More importantly, the graph structure of the network reveals how the network extracts features from MR images, providing intuitive explainability.

7.7LGOct 31, 2023
The Missing U for Efficient Diffusion Models

Sergio Calvo-Ordonez, Chun-Wun Cheng, Jiahao Huang et al.

Diffusion Probabilistic Models stand as a critical tool in generative modelling, enabling the generation of complex data distributions. This family of generative models yields record-breaking performance in tasks such as image synthesis, video generation, and molecule design. Despite their capabilities, their efficiency, especially in the reverse process, remains a challenge due to slow convergence rates and high computational costs. In this paper, we introduce an approach that leverages continuous dynamical systems to design a novel denoising network for diffusion models that is more parameter-efficient, exhibits faster convergence, and demonstrates increased noise robustness. Experimenting with Denoising Diffusion Probabilistic Models (DDPMs), our framework operates with approximately a quarter of the parameters, and $\sim$ 30\% of the Floating Point Operations (FLOPs) compared to standard U-Nets in DDPMs. Furthermore, our model is notably faster in inference than the baseline when measured in fair and equal conditions. We also provide a mathematical intuition as to why our proposed reverse process is faster as well as a mathematical discussion of the empirical tradeoffs in the denoising downstream task. Finally, we argue that our method is compatible with existing performance enhancement techniques, enabling further improvements in efficiency, quality, and speed.

10.7IVJun 20, 2022Code
CS$^2$: A Controllable and Simultaneous Synthesizer of Images and Annotations with Minimal Human Intervention

Xiaodan Xing, Jiahao Huang, Yang Nan et al.

The destitution of image data and corresponding expert annotations limit the training capacities of AI diagnostic models and potentially inhibit their performance. To address such a problem of data and label scarcity, generative models have been developed to augment the training datasets. Previously proposed generative models usually require manually adjusted annotations (e.g., segmentation masks) or need pre-labeling. However, studies have found that these pre-labeling based methods can induce hallucinating artifacts, which might mislead the downstream clinical tasks, while manual adjustment could be onerous and subjective. To avoid manual adjustment and pre-labeling, we propose a novel controllable and simultaneous synthesizer (dubbed CS$^2$) in this study to generate both realistic images and corresponding annotations at the same time. Our CS$^2$ model is trained and validated using high resolution CT (HRCT) data collected from COVID-19 patients to realize an efficient infections segmentation with minimal human intervention. Our contributions include 1) a conditional image synthesis network that receives both style information from reference CT images and structural information from unsupervised segmentation masks, and 2) a corresponding segmentation mask synthesis network to automatically segment these synthesized images simultaneously. Our experimental studies on HRCT scans collected from COVID-19 patients demonstrate that our CS$^2$ model can lead to realistic synthesized datasets and promising segmentation results of COVID infections compared to the state-of-the-art nnUNet trained and fine-tuned in a fully supervised manner.

5.3IVOct 31, 2023
High-Resolution Reference Image Assisted Volumetric Super-Resolution of Cardiac Diffusion Weighted Imaging

Yinzhe Wu, Jiahao Huang, Fanwen Wang et al.

Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) is the only in vivo method to non-invasively examine the microstructure of the human heart. Current research in DT-CMR aims to improve the understanding of how the cardiac microstructure relates to the macroscopic function of the healthy heart as well as how microstructural dysfunction contributes to disease. To get the final DT-CMR metrics, we need to acquire diffusion weighted images of at least 6 directions. However, due to DWI's low signal-to-noise ratio, the standard voxel size is quite big on the scale for microstructures. In this study, we explored the potential of deep-learning-based methods in improving the image quality volumetrically (x4 in all dimensions). This study proposed a novel framework to enable volumetric super-resolution, with an additional model input of high-resolution b0 DWI. We demonstrated that the additional input could offer higher super-resolved image quality. Going beyond, the model is also able to super-resolve DWIs of unseen b-values, proving the model framework's generalizability for cardiac DWI superresolution. In conclusion, we would then recommend giving the model a high-resolution reference image as an additional input to the low-resolution image for training and inference to guide all super-resolution frameworks for parametric imaging where a reference image is available.

3.0IVFeb 28, 2023
Swin Deformable Attention Hybrid U-Net for Medical Image Segmentation

Lichao Wang, Jiahao Huang, Xiaodan Xing et al.

Medical image segmentation is a crucial task in the field of medical image analysis. Harmonizing the convolution and multi-head self-attention mechanism is a recent research focus in this field, with various combination methods proposed. However, the lack of interpretability of these hybrid models remains a common pitfall, limiting their practical application in clinical scenarios. To address this issue, we propose to incorporate the Shifted Window (Swin) Deformable Attention into a hybrid architecture to improve segmentation performance while ensuring explainability. Our proposed Swin Deformable Attention Hybrid UNet (SDAH-UNet) demonstrates state-of-the-art performance on both anatomical and lesion segmentation tasks. Moreover, we provide a direct and visual explanation of the model focalization and how the model forms it, enabling clinicians to better understand and trust the decision of the model. Our approach could be a promising solution to the challenge of developing accurate and interpretable medical image segmentation models.

12.8IVJan 23, 2022Code
Fast MRI Reconstruction: How Powerful Transformers Are?

Jiahao Huang, Yinzhe Wu, Huanjun Wu et al.

Magnetic resonance imaging (MRI) is a widely used non-radiative and non-invasive method for clinical interrogation of organ structures and metabolism, with an inherently long scanning time. Methods by k-space undersampling and deep learning based reconstruction have been popularised to accelerate the scanning process. This work focuses on investigating how powerful transformers are for fast MRI by exploiting and comparing different novel network architectures. In particular, a generative adversarial network (GAN) based Swin transformer (ST-GAN) was introduced for the fast MRI reconstruction. To further preserve the edge and texture information, edge enhanced GAN based Swin transformer (EES-GAN) and texture enhanced GAN based Swin transformer (TES-GAN) were also developed, where a dual-discriminator GAN structure was applied. We compared our proposed GAN based transformers, standalone Swin transformer and other convolutional neural networks based GAN model in terms of the evaluation metrics PSNR, SSIM and FID. We showed that transformers work well for the MRI reconstruction from different undersampling conditions. The utilisation of GAN's adversarial structure improves the quality of images reconstructed when undersampled for 30% or higher. The code is publicly available at https://github.com/ayanglab/SwinGANMR.

28.2IVJan 10, 2022Code
Swin Transformer for Fast MRI

Jiahao Huang, Yingying Fang, Yinzhe Wu et al.

Magnetic resonance imaging (MRI) is an important non-invasive clinical tool that can produce high-resolution and reproducible images. However, a long scanning time is required for high-quality MR images, which leads to exhaustion and discomfort of patients, inducing more artefacts due to voluntary movements of the patients and involuntary physiological movements. To accelerate the scanning process, methods by k-space undersampling and deep learning based reconstruction have been popularised. This work introduced SwinMR, a novel Swin transformer based method for fast MRI reconstruction. The whole network consisted of an input module (IM), a feature extraction module (FEM) and an output module (OM). The IM and OM were 2D convolutional layers and the FEM was composed of a cascaded of residual Swin transformer blocks (RSTBs) and 2D convolutional layers. The RSTB consisted of a series of Swin transformer layers (STLs). The shifted windows multi-head self-attention (W-MSA/SW-MSA) of STL was performed in shifted windows rather than the multi-head self-attention (MSA) of the original transformer in the whole image space. A novel multi-channel loss was proposed by using the sensitivity maps, which was proved to reserve more textures and details. We performed a series of comparative studies and ablation studies in the Calgary-Campinas public brain MR dataset and conducted a downstream segmentation experiment in the Multi-modal Brain Tumour Segmentation Challenge 2017 dataset. The results demonstrate our SwinMR achieved high-quality reconstruction compared with other benchmark methods, and it shows great robustness with different undersampling masks, under noise interruption and on different datasets. The code is publicly available at https://github.com/ayanglab/SwinMR.

21.1LGFeb 5, 2024
HAMLET: Graph Transformer Neural Operator for Partial Differential Equations

Andrey Bryutkin, Jiahao Huang, Zhongying Deng et al.

We present a novel graph transformer framework, HAMLET, designed to address the challenges in solving partial differential equations (PDEs) using neural networks. The framework uses graph transformers with modular input encoders to directly incorporate differential equation information into the solution process. This modularity enhances parameter correspondence control, making HAMLET adaptable to PDEs of arbitrary geometries and varied input formats. Notably, HAMLET scales effectively with increasing data complexity and noise, showcasing its robustness. HAMLET is not just tailored to a single type of physical simulation, but can be applied across various domains. Moreover, it boosts model resilience and performance, especially in scenarios with limited data. We demonstrate, through extensive experiments, that our framework is capable of outperforming current techniques for PDEs.

8.6IVJun 19, 2025
From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction

Zhenxuan Zhang, Lipei Zhang, Yanqi Cheng et al.

In motion-robust magnetic resonance imaging (MRI), slice-to-volume reconstruction is critical for recovering anatomically consistent 3D brain volumes from 2D slices, especially under accelerated acquisitions or patient motion. However, this task remains challenging due to hierarchical structural disruptions. It includes local detail loss from k-space undersampling, global structural aliasing caused by motion, and volumetric anisotropy. Therefore, we propose a progressive refinement implicit neural representation (PR-INR) framework. Our PR-INR unifies motion correction, structural refinement, and volumetric synthesis within a geometry-aware coordinate space. Specifically, a motion-aware diffusion module is first employed to generate coarse volumetric reconstructions that suppress motion artifacts and preserve global anatomical structures. Then, we introduce an implicit detail restoration module that performs residual refinement by aligning spatial coordinates with visual features. It corrects local structures and enhances boundary precision. Further, a voxel continuous-aware representation module represents the image as a continuous function over 3D coordinates. It enables accurate inter-slice completion and high-frequency detail recovery. We evaluate PR-INR on five public MRI datasets under various motion conditions (3% and 5% displacement), undersampling rates (4x and 8x) and slice resolutions (scale = 5). Experimental results demonstrate that PR-INR outperforms state-of-the-art methods in both quantitative reconstruction metrics and visual quality. It further shows generalization and robustness across diverse unseen domains.

5.1IVApr 25, 2025
RSFR: A Coarse-to-Fine Reconstruction Framework for Diffusion Tensor Cardiac MRI with Semantic-Aware Refinement

Jiahao Huang, Fanwen Wang, Pedro F. Ferreira et al.

Cardiac diffusion tensor imaging (DTI) offers unique insights into cardiomyocyte arrangements, bridging the gap between microscopic and macroscopic cardiac function. However, its clinical utility is limited by technical challenges, including a low signal-to-noise ratio, aliasing artefacts, and the need for accurate quantitative fidelity. To address these limitations, we introduce RSFR (Reconstruction, Segmentation, Fusion & Refinement), a novel framework for cardiac diffusion-weighted image reconstruction. RSFR employs a coarse-to-fine strategy, leveraging zero-shot semantic priors via the Segment Anything Model and a robust Vision Mamba-based reconstruction backbone. Our framework integrates semantic features effectively to mitigate artefacts and enhance fidelity, achieving state-of-the-art reconstruction quality and accurate DT parameter estimation under high undersampling rates. Extensive experiments and ablation studies demonstrate the superior performance of RSFR compared to existing methods, highlighting its robustness, scalability, and potential for clinical translation in quantitative cardiac DTI.

8.5IVJun 24, 2024
Diff3Dformer: Leveraging Slice Sequence Diffusion for Enhanced 3D CT Classification with Transformer Networks

Zihao Jin, Yingying Fang, Jiahao Huang et al.

The manifestation of symptoms associated with lung diseases can vary in different depths for individual patients, highlighting the significance of 3D information in CT scans for medical image classification. While Vision Transformer has shown superior performance over convolutional neural networks in image classification tasks, their effectiveness is often demonstrated on sufficiently large 2D datasets and they easily encounter overfitting issues on small medical image datasets. To address this limitation, we propose a Diffusion-based 3D Vision Transformer (Diff3Dformer), which utilizes the latent space of the Diffusion model to form the slice sequence for 3D analysis and incorporates clustering attention into ViT to aggregate repetitive information within 3D CT scans, thereby harnessing the power of the advanced transformer in 3D classification tasks on small datasets. Our method exhibits improved performance on two different scales of small datasets of 3D lung CT scans, surpassing the state of the art 3D methods and other transformer-based approaches that emerged during the COVID-19 pandemic, demonstrating its robust and superior performance across different scales of data. Experimental results underscore the superiority of our proposed method, indicating its potential for enhancing medical image classification tasks in real-world scenarios.

11.0IVDec 10, 2021
Edge-Enhanced Dual Discriminator Generative Adversarial Network for Fast MRI with Parallel Imaging Using Multi-view Information

Jiahao Huang, Weiping Ding, Jun Lv et al.

In clinical medicine, magnetic resonance imaging (MRI) is one of the most important tools for diagnosis, triage, prognosis, and treatment planning. However, MRI suffers from an inherent slow data acquisition process because data is collected sequentially in k-space. In recent years, most MRI reconstruction methods proposed in the literature focus on holistic image reconstruction rather than enhancing the edge information. This work steps aside this general trend by elaborating on the enhancement of edge information. Specifically, we introduce a novel parallel imaging coupled dual discriminator generative adversarial network (PIDD-GAN) for fast multi-channel MRI reconstruction by incorporating multi-view information. The dual discriminator design aims to improve the edge information in MRI reconstruction. One discriminator is used for holistic image reconstruction, whereas the other one is responsible for enhancing edge information. An improved U-Net with local and global residual learning is proposed for the generator. Frequency channel attention blocks (FCA Blocks) are embedded in the generator for incorporating attention mechanisms. Content loss is introduced to train the generator for better reconstruction quality. We performed comprehensive experiments on Calgary-Campinas public brain MR dataset and compared our method with state-of-the-art MRI reconstruction methods. Ablation studies of residual learning were conducted on the MICCAI13 dataset to validate the proposed modules. Results show that our PIDD-GAN provides high-quality reconstructed MR images, with well-preserved edge information. The time of single-image reconstruction is below 5ms, which meets the demand of faster processing.