14.4CVFeb 27, 2025
Open-Vocabulary Semantic Part Segmentation of 3D HumanKeito Suzuki, Bang Du, Girish Krishnan et al.
3D part segmentation is still an open problem in the field of 3D vision and AR/VR. Due to limited 3D labeled data, traditional supervised segmentation methods fall short in generalizing to unseen shapes and categories. Recently, the advancement in vision-language models' zero-shot abilities has brought a surge in open-world 3D segmentation methods. While these methods show promising results for 3D scenes or objects, they do not generalize well to 3D humans. In this paper, we present the first open-vocabulary segmentation method capable of handling 3D human. Our framework can segment the human category into desired fine-grained parts based on the textual prompt. We design a simple segmentation pipeline, leveraging SAM to generate multi-view proposals in 2D and proposing a novel HumanCLIP model to create unified embeddings for visual and textual inputs. Compared with existing pre-trained CLIP models, the HumanCLIP model yields more accurate embeddings for human-centric contents. We also design a simple-yet-effective MaskFusion module, which classifies and fuses multi-view features into 3D semantic masks without complex voting and grouping mechanisms. The design of decoupling mask proposals and text input also significantly boosts the efficiency of per-prompt inference. Experimental results on various 3D human datasets show that our method outperforms current state-of-the-art open-vocabulary 3D segmentation methods by a large margin. In addition, we show that our method can be directly applied to various 3D representations including meshes, point clouds, and 3D Gaussian Splatting.
10.5CVNov 23, 2024
SplatSDF: Boosting Neural Implicit SDF via Gaussian Splatting FusionRunfa Blark Li, Keito Suzuki, Bang Du et al.
A signed distance function (SDF) is a useful representation for continuous-space geometry and many related operations, including rendering, collision checking, and mesh generation. Hence, reconstructing SDF from image observations accurately and efficiently is a fundamental problem. Recently, neural implicit SDF (SDF-NeRF) techniques, trained using volumetric rendering, have gained a lot of attention. Compared to earlier truncated SDF (TSDF) fusion algorithms that rely on depth maps and voxelize continuous space, SDF-NeRF enables continuous-space SDF reconstruction with better geometric and photometric accuracy. However, the accuracy and convergence speed of scene-level SDF reconstruction require further improvements for many applications. With the advent of 3D Gaussian Splatting (3DGS) as an explicit representation with excellent rendering quality and speed, several works have focused on improving SDF-NeRF by introducing consistency losses on depth and surface normals between 3DGS and SDF-NeRF. However, loss-level connections alone lead to incremental improvements. We propose a novel neural implicit SDF called "SplatSDF" to fuse 3DGSandSDF-NeRF at an architecture level with significant boosts to geometric and photometric accuracy and convergence speed. Our SplatSDF relies on 3DGS as input only during training, and keeps the same complexity and efficiency as the original SDF-NeRF during inference. Our method outperforms state-of-the-art SDF-NeRF models on geometric and photometric evaluation by the time of submission.
6.2CVApr 22, 2025
A Clinician-Friendly Platform for Ophthalmic Image Analysis Without Technical BarriersMeng Wang, Tian Lin, Qingshan Hou et al.
Artificial intelligence (AI) shows remarkable potential in medical imaging diagnostics, yet most current models require retraining when applied across different clinical settings, limiting their scalability. We introduce GlobeReady, a clinician-friendly AI platform that enables fundus disease diagnosis that operates without retraining, fine-tuning, or the needs for technical expertise. GlobeReady demonstrates high accuracy across imaging modalities: 93.9-98.5% for 11 fundus diseases using color fundus photographs (CPFs) and 87.2-92.7% for 15 fundus diseases using optic coherence tomography (OCT) scans. By leveraging training-free local feature augmentation, GlobeReady platform effectively mitigates domain shifts across centers and populations, achieving accuracies of 88.9-97.4% across five centers on average in China, 86.3-96.9% in Vietnam, and 73.4-91.0% in Singapore, and 90.2-98.9% in the UK. Incorporating a bulit-in confidence-quantifiable diagnostic mechanism further enhances the platform's accuracy to 94.9-99.4% with CFPs and 88.2-96.2% with OCT, while enabling identification of out-of-distribution cases with 86.3% accuracy across 49 common and rare fundus diseases using CFPs, and 90.6% accuracy across 13 diseases using OCT. Clinicians from countries rated GlobeReady highly for usability and clinical relevance (average score 4.6/5). These findings demonstrate GlobeReady's robustness, generalizability and potential to support global ophthalmic care without technical barriers.
5.1IVFeb 25, 2025
A graph neural network-based multispectral-view learning model for diabetic macular ischemia detection from color fundus photographsQinghua He, Hongyang Jiang, Danqi Fang et al.
Diabetic macular ischemia (DMI), marked by the loss of retinal capillaries in the macular area, contributes to vision impairment in patients with diabetes. Although color fundus photographs (CFPs), combined with artificial intelligence (AI), have been extensively applied in detecting various eye diseases, including diabetic retinopathy (DR), their applications in detecting DMI remain unexplored, partly due to skepticism among ophthalmologists regarding its feasibility. In this study, we propose a graph neural network-based multispectral view learning (GNN-MSVL) model designed to detect DMI from CFPs. The model leverages higher spectral resolution to capture subtle changes in fundus reflectance caused by ischemic tissue, enhancing sensitivity to DMI-related features. The proposed approach begins with computational multispectral imaging (CMI) to reconstruct 24-wavelength multispectral fundus images from CFPs. ResNeXt101 is employed as the backbone for multi-view learning to extract features from the reconstructed images. Additionally, a GNN with a customized jumper connection strategy is designed to enhance cross-spectral relationships, facilitating comprehensive and efficient multispectral view learning. The study included a total of 1,078 macula-centered CFPs from 1,078 eyes of 592 patients with diabetes, of which 530 CFPs from 530 eyes of 300 patients were diagnosed with DMI. The model achieved an accuracy of 84.7 percent and an area under the receiver operating characteristic curve (AUROC) of 0.900 (95 percent CI: 0.852-0.937) on eye-level, outperforming both the baseline model trained from CFPs and human experts (p-values less than 0.01). These findings suggest that AI-based CFP analysis holds promise for detecting DMI, contributing to its early and low-cost screening.