8.8SPJul 9
SpO$_2$ Predictor-Guided Stage-Wise Time-Frequency Reconstruction of Low-Quality Dual-Wavelength PPG for Oxygen Saturation EstimationZequan Liang, Elahe Hosseini, Ning Miao et al.
Continuous oxygen saturation (SpO$_2$) estimation from wearable photoplethysmography (PPG) is important for long-term health monitoring, but low-quality red and infrared PPG segments can distort waveform morphology and degrade SpO$_2$ prediction accuracy. Existing PPG denoising and reconstruction methods usually optimize waveform fidelity or heart rate characteristics, while time-domain waveform loss on PPG signals alone insufficiently preserves frequency structure and SpO$_2$-relevant information. This paper proposes a SpO$_2$ predictor-guided stage-wise time-frequency reconstruction framework for low-quality dual-wavelength PPG signals. The proposed method first selects high-quality PPG segments to pretrain a SpO$_2$ predictor. A masked reconstruction model is then trained to recover randomly masked PPG regions using a joint reconstruction objective that combines time-domain waveform loss with frequency-domain loss computed from the short-time Fourier transform (STFT). To make the reconstruction task physiologically relevant, the pretrained SpO$_2$ predictor is incorporated as an additional constraint, encouraging the reconstructed PPG to preserve SpO$_2$ information rather than only minimizing waveform reconstruction error. The SpO$_2$ predictor and PPG reconstructor model are optimized through four training stages. Experiments on the public OpenOximetry Repository and a private wearable PPG dataset show that the proposed approach achieves the lowest subject-level MAE, with 2.882\% on the public dataset and 2.359\% on the private dataset.
6.8SPJul 9
Unit-Independent Low-Rate Wrist GSR Processing for Stress Detection Using Phasic nSCR FeaturesZequan Liang, Sally Hang, Geneva M. Jost et al.
Galvanic skin response (GSR) is widely used for stress detection, but wrist-based GSR remains challenging because its absolute amplitude can differ substantially from laboratory-grade palmar measurements. In this paper, we propose a unit-independent low-rate wrist GSR processing pipeline to extract the number of skin conductance responses per minute (nSCR/min) as a stress-related feature. We collect paired wrist and palmar GSR recordings from 31 participants during sitting baseline, standing baseline, neutral speaking, and the Trier Social Stress Test (TSST), a laboratory social stressor task. The proposed pipeline cleans the raw GSR signal, decomposes it into tonic skin conductance level (SCL) and phasic skin conductance response (SCR), applies robust z-score normalization, and detects phasic SCR peaks to compute nSCR/min. Using random forest on 25Hz We-Be GSR, nSCR/min achieved balanced accuracies of 0.823 and 0.871 for binary classification between TSST and the sitting and standing baselines, respectively. Moreover, the 25Hz We-Be GSR features achieved comparable balanced accuracy to the original 100Hz features across the evaluated tasks. These results suggest the feasibility of low-rate, unit-independent wrist GSR processing for wearable stress detection.
7.4ETMay 15
Lightweight Cross-Device Sleep Tracking on the WeBe Wearable PlatformWei Shao, Ehsan Kourkchi, Krishi Prashant Shah et al.
Wearable devices are widely used for continuous health monitoring, yet reliable sleep tracking on emerging platforms remains underexplored due to reliance on proprietary algorithms and device-specific activity representations. We present a lightweight and reproducible sleep tracking pipeline that operates directly on raw accelerometer signals. The method converts data into epoch-level activity features, applies temporal smoothing and normalized scoring, and performs sleep/wake classification using a globally calibrated threshold. We calibrate the model on the Multilevel Monitoring of Activity and Sleep in Healthy People (MMASH) dataset and evaluate it in a cross-device study using the WeBe wearable platform and a commercial ActiGraph device. On MMASH, the method achieves a mean absolute error of 41.6 minutes in Total Sleep Time (TST), with onset and offset errors of 6.3 and 7.4 minutes. On real-world WeBe data from three participants across five sessions, it achieves a mean TST error of 27.4 minutes and onset and offset errors of 13.9 and 8.0 minutes. In contrast, a commercial ActiGraph pipeline shows larger discrepancies relative to ground truth. These results demonstrate accurate and generalizable sleep tracking using a simple and reproducible pipeline.