4.3MED-PHMay 1, 2024
Continuous sPatial-Temporal Deformable Image Registration (CPT-DIR) for motion modelling in radiotherapy: beyond classic voxel-based methodsXia Li, Runzhao Yang, Muheng Li et al.
Deformable image registration (DIR) is a crucial tool in radiotherapy for analyzing anatomical changes and motion patterns. Current DIR implementations rely on discrete volumetric motion representation, which often leads to compromised accuracy and uncertainty when handling significant anatomical changes and sliding boundaries. This limitation affects the reliability of subsequent contour propagation and dose accumulation procedures, particularly in regions with complex anatomical interfaces such as the lung-chest wall boundary. Given that organ motion is inherently a continuous process in both space and time, we aimed to develop a model that preserves these fundamental properties. Drawing inspiration from fluid mechanics, we propose a novel approach using implicit neural representation (INR) for continuous modeling of patient anatomical motion. This approach ensures spatial and temporal continuity while effectively unifying Eulerian and Lagrangian specifications to enable natural continuous motion modeling and frame interpolation. The integration of these specifications provides a more comprehensive understanding of anatomical deformation patterns. By leveraging the continuous representations, the CPT-DIR method significantly enhances registration and interpolation accuracy, automation, and speed. The method demonstrates superior performance in landmark and contour precision, particularly in challenging anatomical regions, representing a substantial advancement over conventional approaches in deformable image registration. The improved efficiency and accuracy of CPT-DIR make it particularly suitable for real-time adaptive radiotherapy applications.
3.3MED-PHApr 17, 2024
Diffusion Schrödinger Bridge Models for High-Quality MR-to-CT Synthesis for Head and Neck Proton Treatment PlanningMuheng Li, Xia Li, Sairos Safai et al.
In recent advancements in proton therapy, MR-based treatment planning is gaining momentum to minimize additional radiation exposure compared to traditional CT-based methods. This transition highlights the critical need for accurate MR-to-CT image synthesis, which is essential for precise proton dose calculations. Our research introduces the Diffusion Schrödinger Bridge Models (DSBM), an innovative approach for high-quality MR-to-CT synthesis. DSBM learns the nonlinear diffusion processes between MR and CT data distributions. This method improves upon traditional diffusion models by initiating synthesis from the prior distribution rather than the Gaussian distribution, enhancing both generation quality and efficiency. We validated the effectiveness of DSBM on a head and neck cancer dataset, demonstrating its superiority over traditional image synthesis methods through both image-level and dosimetric-level evaluations. The effectiveness of DSBM in MR-based proton treatment planning highlights its potential as a valuable tool in various clinical scenarios.
3.7CVMay 24, 2024
CPT-Interp: Continuous sPatial and Temporal Motion Modeling for 4D Medical Image InterpolationXia Li, Runzhao Yang, Xiangtai Li et al.
Motion information from 4D medical imaging offers critical insights into dynamic changes in patient anatomy for clinical assessments and radiotherapy planning and, thereby, enhances the capabilities of 3D image analysis. However, inherent physical and technical constraints of imaging hardware often necessitate a compromise between temporal resolution and image quality. Frame interpolation emerges as a pivotal solution to this challenge. Previous methods often suffer from discretion when they estimate the intermediate motion and execute the forward warping. In this study, we draw inspiration from fluid mechanics to propose a novel approach for continuously modeling patient anatomic motion using implicit neural representation. It ensures both spatial and temporal continuity, effectively bridging Eulerian and Lagrangian specifications together to naturally facilitate continuous frame interpolation. Our experiments across multiple datasets underscore the method's superior accuracy and speed. Furthermore, as a case-specific optimization (training-free) approach, it circumvents the need for extensive datasets and addresses model generalization issues.
3.6CVSep 22, 2025
CPT-4DMR: Continuous sPatial-Temporal Representation for 4D-MRI ReconstructionXinyang Wu, Muheng Li, Xia Li et al.
Four-dimensional MRI (4D-MRI) is an promising technique for capturing respiratory-induced motion in radiation therapy planning and delivery. Conventional 4D reconstruction methods, which typically rely on phase binning or separate template scans, struggle to capture temporal variability, complicate workflows, and impose heavy computational loads. We introduce a neural representation framework that considers respiratory motion as a smooth, continuous deformation steered by a 1D surrogate signal, completely replacing the conventional discrete sorting approach. The new method fuses motion modeling with image reconstruction through two synergistic networks: the Spatial Anatomy Network (SAN) encodes a continuous 3D anatomical representation, while a Temporal Motion Network (TMN), guided by Transformer-derived respiratory signals, produces temporally consistent deformation fields. Evaluation using a free-breathing dataset of 19 volunteers demonstrates that our template- and phase-free method accurately captures both regular and irregular respiratory patterns, while preserving vessel and bronchial continuity with high anatomical fidelity. The proposed method significantly improves efficiency, reducing the total processing time from approximately five hours required by conventional discrete sorting methods to just 15 minutes of training. Furthermore, it enables inference of each 3D volume in under one second. The framework accurately reconstructs 3D images at any respiratory state, achieves superior performance compared to conventional methods, and demonstrates strong potential for application in 4D radiation therapy planning and real-time adaptive treatment.
1.2MED-PHSep 22, 2025
Neural Network-Driven Direct CBCT-Based Dose Calculation for Head-and-Neck Proton Treatment PlanningMuheng Li, Evangelia Choulilitsa, Lisa Fankhauser et al.
Accurate dose calculation on cone beam computed tomography (CBCT) images is essential for modern proton treatment planning workflows, particularly when accounting for inter-fractional anatomical changes in adaptive treatment scenarios. Traditional CBCT-based dose calculation suffers from image quality limitations, requiring complex correction workflows. This study develops and validates a deep learning approach for direct proton dose calculation from CBCT images using extended Long Short-Term Memory (xLSTM) neural networks. A retrospective dataset of 40 head-and-neck cancer patients with paired planning CT and treatment CBCT images was used to train an xLSTM-based neural network (CBCT-NN). The architecture incorporates energy token encoding and beam's-eye-view sequence modelling to capture spatial dependencies in proton dose deposition patterns. Training utilized 82,500 paired beam configurations with Monte Carlo-generated ground truth doses. Validation was performed on 5 independent patients using gamma analysis, mean percentage dose error assessment, and dose-volume histogram comparison. The CBCT-NN achieved gamma pass rates of 95.1 $\pm$ 2.7% using 2mm/2% criteria. Mean percentage dose errors were 2.6 $\pm$ 1.4% in high-dose regions ($>$90% of max dose) and 5.9 $\pm$ 1.9% globally. Dose-volume histogram analysis showed excellent preservation of target coverage metrics (Clinical Target Volume V95% difference: -0.6 $\pm$ 1.1%) and organ-at-risk constraints (parotid mean dose difference: -0.5 $\pm$ 1.5%). Computation time is under 3 minutes without sacrificing Monte Carlo-level accuracy. This study demonstrates the proof-of-principle of direct CBCT-based proton dose calculation using xLSTM neural networks. The approach eliminates traditional correction workflows while achieving comparable accuracy and computational efficiency suitable for adaptive protocols.
2.3MED-PHFeb 8, 2024
Neural Graphics Primitives-based Deformable Image Registration for On-the-fly Motion ExtractionXia Li, Fabian Zhang, Muheng Li et al.
Intra-fraction motion in radiotherapy is commonly modeled using deformable image registration (DIR). However, existing methods often struggle to balance speed and accuracy, limiting their applicability in clinical scenarios. This study introduces a novel approach that harnesses Neural Graphics Primitives (NGP) to optimize the displacement vector field (DVF). Our method leverages learned primitives, processed as splats, and interpolates within space using a shallow neural network. Uniquely, it enables self-supervised optimization at an ultra-fast speed, negating the need for pre-training on extensive datasets and allowing seamless adaptation to new cases. We validated this approach on the 4D-CT lung dataset DIR-lab, achieving a target registration error (TRE) of 1.15\pm1.15 mm within a remarkable time of 1.77 seconds. Notably, our method also addresses the sliding boundary problem, a common challenge in conventional DIR methods.
2.0IVAug 26, 2019
Accelerated Motion-Aware MR Imaging via Motion Prediction from K-Space CenterChristoph Jud, Damien Nguyen, Alina Giger et al.
Motion has been a challenge for magnetic resonance (MR) imaging ever since the MR has been invented. Especially in volumetric imaging of thoracic and abdominal organs, motion-awareness is essential for reducing motion artifacts in the final image. A recently proposed MR imaging approach copes with motion by observing the motion patterns during the acquisition. Repetitive scanning of the k-space center region enables the extraction of the patient motion while acquiring the remaining part of the k-space. Due to highly redundant measurements of the center, the required scanning time of over 11 min and the reconstruction time of 2 h exceed clinical applicability though. We propose an accelerated motion-aware MR imaging method where the motion is inferred from small-sized k-space center patches and an initial training phase during which the characteristic movements are modeled. Thereby, acquisition times are reduced by a factor of almost 2 and reconstruction times by two orders of magnitude. Moreover, we improve the existing motion-aware approach with a systematic temporal shift correction to achieve a sharper image reconstruction. We tested our method on 12 volunteers and scanned their lungs and abdomen under free breathing. We achieved equivalent to higher reconstruction quality using the motion-prediction compared to the slower existing approach.