CVSep 1, 2024
McCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI SynthesisSanuwani Dayarathna, Kh Tohidul Islam, Bohan Zhuang et al.
Magnetic Resonance Imaging (MRI) is instrumental in clinical diagnosis, offering diverse contrasts that provide comprehensive diagnostic information. However, acquiring multiple MRI contrasts is often constrained by high costs, long scanning durations, and patient discomfort. Current synthesis methods, typically focused on single-image contrasts, fall short in capturing the collective nuances across various contrasts. Moreover, existing methods for multi-contrast MRI synthesis often fail to accurately map feature-level information across multiple imaging contrasts. We introduce McCaD (Multi-Contrast MRI Conditioned Adaptive Adversarial Diffusion), a novel framework leveraging an adversarial diffusion model conditioned on multiple contrasts for high-fidelity MRI synthesis. McCaD significantly enhances synthesis accuracy by employing a multi-scale, feature-guided mechanism, incorporating denoising and semantic encoders. An adaptive feature maximization strategy and a spatial feature-attentive loss have been introduced to capture more intrinsic features across multiple contrasts. This facilitates a precise and comprehensive feature-guided denoising process. Extensive experiments on tumor and healthy multi-contrast MRI datasets demonstrated that the McCaD outperforms state-of-the-art baselines quantitively and qualitatively. The code is provided with supplementary materials.
CVMar 11
Towards Trustworthy Selective Generation: Reliability-Guided Diffusion for Ultra-Low-Field to High-Field MRI SynthesisZhenxuan Zhang, Peiyuan Jing, Ruicheng Yuan et al.
Low-field to high-field MRI synthesis has emerged as a cost-effective strategy to enhance image quality under hardware and acquisition constraints, particularly in scenarios where access to high-field scanners is limited or impractical. Despite recent progress in diffusion models, diffusion-based approaches often struggle to balance fine-detail recovery and structural fidelity. In particular, the uncontrolled generation of high-resolution details in structurally ambiguous regions may introduce anatomically inconsistent patterns, such as spurious edges or artificial texture variations. These artifacts can bias downstream quantitative analysis. For example, they may cause inaccurate tissue boundary delineation or erroneous volumetric estimation, ultimately reducing clinical trust in synthesized images. These limitations highlight the need for generative models that are not only visually accurate but also spatially reliable and anatomically consistent. To address this issue, we propose a reliability-aware diffusion framework (ReDiff) that improves synthesis robustness at both the sampling and post-generation stages. Specifically, we introduce a reliability-guided sampling strategy to suppress unreliable responses during the denoising process. We further develop an uncertainty-aware multi-candidate selection scheme to enhance the reliability of the final prediction. Experiments on multi-center MRI datasets demonstrate improved structural fidelity and reduced artifacts compared with state-of-the-art methods.
CVOct 15, 2025
Cyclic Self-Supervised Diffusion for Ultra Low-field to High-field MRI SynthesisZhenxuan Zhang, Peiyuan Jing, Zi Wang et al.
Synthesizing high-quality images from low-field MRI holds significant potential. Low-field MRI is cheaper, more accessible, and safer, but suffers from low resolution and poor signal-to-noise ratio. This synthesis process can reduce reliance on costly acquisitions and expand data availability. However, synthesizing high-field MRI still suffers from a clinical fidelity gap. There is a need to preserve anatomical fidelity, enhance fine-grained structural details, and bridge domain gaps in image contrast. To address these issues, we propose a \emph{cyclic self-supervised diffusion (CSS-Diff)} framework for high-field MRI synthesis from real low-field MRI data. Our core idea is to reformulate diffusion-based synthesis under a cycle-consistent constraint. It enforces anatomical preservation throughout the generative process rather than just relying on paired pixel-level supervision. The CSS-Diff framework further incorporates two novel processes. The slice-wise gap perception network aligns inter-slice inconsistencies via contrastive learning. The local structure correction network enhances local feature restoration through self-reconstruction of masked and perturbed patches. Extensive experiments on cross-field synthesis tasks demonstrate the effectiveness of our method, achieving state-of-the-art performance (e.g., 31.80 $\pm$ 2.70 dB in PSNR, 0.943 $\pm$ 0.102 in SSIM, and 0.0864 $\pm$ 0.0689 in LPIPS). Beyond pixel-wise fidelity, our method also preserves fine-grained anatomical structures compared with the original low-field MRI (e.g., left cerebral white matter error drops from 12.1$\%$ to 2.1$\%$, cortex from 4.2$\%$ to 3.7$\%$). To conclude, our CSS-Diff can synthesize images that are both quantitatively reliable and anatomically consistent.