Anatomy-Guided Residual Motion Diffusion for Controllable 4D Cardiac MRI SynthesisYiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang et al.
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation. A semi-supervised variational autoencoder learns a compact latent representation of anatomical volumes while jointly predicting aligned segmentation masks in a unified framework. Anatomical structure is then disentangled from temporal dynamics through a cascaded latent diffusion model (LDM). A static LDM generates subject-specific anatomy conditioned on clinical priors (diagnosis and volumes measures) and a subsequent motion LDM estimates residual latent motions, ensuring strict temporal coherence across the 4D sequence. The proposed approach was evaluated on cine cardiac MRI as a representative 4D imaging application. Experiments across multiple datasets demonstrate high controllability of static anatomy (Pearson r > 0.8) and strong temporal coherence (FVD = 288.08). In cross-vendor generalization experiments, augmenting training sets with synthetic 4D sequences significantly improves downstream segmentation performance. Using nnU-Net, the proposed augmentation strategy improves the average Dice score by 1.4% and reduces the Hausdorff Distance by 3.0mm compared to training on real data alone, for the left ventricle, Dice improves by 2.8% with a 5.4mm reduction in boundary error. Overall, this framework provides a scalable and controllable solution for 4D medical image synthesis, supporting the development of more robust models with limited annotations and cross-vendor variability. Code available on https://github.com/cyiheng/4DCardiacMRISynthesis.
1.5CVJun 8
Temporally Consistent and Controllable Video Generation of 2D Cine CMR via Latent Space Motion ModelingYiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang et al.
Cine cardiac magnetic resonance is the gold standard for assessing cardiac function, but the scarcity of public datasets limits the development of advanced data-driven models. To address this limitation, we propose a generative method for synthesizing temporally coherent and anatomically consistent cardiac sequences. Our text-to-video framework decouples cardiac spatial structure from temporal motion. First, a fine-tuned diffusion model synthesizes an initial frame from a clinical text prompt, controlling anatomical features. Then, a latent flow model conditioned on a cardiac phase embedding generates the complete cardiac motion, ensuring spatial consistency and temporal control. Our model generates anatomically and pathologically diverse sequences with high temporal coherence and strong fidelity to input prompts, achieving a FID of 31.68 for image realism and a CLIP score of 31.04 for text-image alignment. These experimental results highlight its potential to produce high-fidelity, on-demand medical data, offering a scalable solution to data scarcity.
2.0CVMar 29, 2024
CT respiratory motion synthesis using joint supervised and adversarial learningYi-Heng Cao, Vincent Bourbonne, François Lucia et al.
Objective: Four-dimensional computed tomography (4DCT) imaging consists in reconstructing a CT acquisition into multiple phases to track internal organ and tumor motion. It is commonly used in radiotherapy treatment planning to establish planning target volumes. However, 4DCT increases protocol complexity, may not align with patient breathing during treatment, and lead to higher radiation delivery. Approach: In this study, we propose a deep synthesis method to generate pseudo respiratory CT phases from static images for motion-aware treatment planning. The model produces patient-specific deformation vector fields (DVFs) by conditioning synthesis on external patient surface-based estimation, mimicking respiratory monitoring devices. A key methodological contribution is to encourage DVF realism through supervised DVF training while using an adversarial term jointly not only on the warped image but also on the magnitude of the DVF itself. This way, we avoid excessive smoothness typically obtained through deep unsupervised learning, and encourage correlations with the respiratory amplitude. Main results: Performance is evaluated using real 4DCT acquisitions with smaller tumor volumes than previously reported. Results demonstrate for the first time that the generated pseudo-respiratory CT phases can capture organ and tumor motion with similar accuracy to repeated 4DCT scans of the same patient. Mean inter-scans tumor center-of-mass distances and Dice similarity coefficients were $1.97$mm and $0.63$, respectively, for real 4DCT phases and $2.35$mm and $0.71$ for synthetic phases, and compares favorably to a state-of-the-art technique (RMSim).