Handling Supervision Scarcity in Chest X-ray Classification: Long-Tailed and Zero-Shot LearningHa-Hieu Pham, Hai-Dang Nguyen, Thanh-Huy Nguyen et al.
Chest X-Ray (CXR) classification in clinical practice is often limited by imperfect supervision, arising from (i) extreme long-tailed multi-label disease distributions and (ii) missing annotations for rare or previously unseen findings. The CXR-LT 2026 challenge addresses these issues on a PadChest-based benchmark with a 36-class label space split into 30 in-distribution classes for training and 6 out-of-distribution (OOD) classes for zero-shot evaluation. We present task-specific solutions tailored to the distinct supervision regimes. For Task 1 (long-tailed multi-label classification), we adopt an imbalance-aware multi-label learning strategy to improve recognition of tail classes while maintaining stable performance on frequent findings. For Task 2 (zero-shot OOD recognition), we propose a prediction approach that produces scores for unseen disease categories without using any supervised labels or examples from the OOD classes during training. Evaluated with macro-averaged mean Average Precision (mAP), our method achieves strong performance on both tasks, ranking first on the public leaderboard of the development phase. Code and pre-trained models are available at https://github.com/hieuphamha19/CXR_LT.
0.6CLJan 16
CTest-Metric: A Unified Framework to Assess Clinical Validity of Metrics for CT Report GenerationVanshali Sharma, Andrea Mia Bejar, Gorkem Durak et al.
In the generative AI era, where even critical medical tasks are increasingly automated, radiology report generation (RRG) continues to rely on suboptimal metrics for quality assessment. Developing domain-specific metrics has therefore been an active area of research, yet it remains challenging due to the lack of a unified, well-defined framework to assess their robustness and applicability in clinical contexts. To address this, we present CTest-Metric, a first unified metric assessment framework with three modules determining the clinical feasibility of metrics for CT RRG. The modules test: (i) Writing Style Generalizability (WSG) via LLM-based rephrasing; (ii) Synthetic Error Injection (SEI) at graded severities; and (iii) Metrics-vs-Expert correlation (MvE) using clinician ratings on 175 "disagreement" cases. Eight widely used metrics (BLEU, ROUGE, METEOR, BERTScore-F1, F1-RadGraph, RaTEScore, GREEN Score, CRG) are studied across seven LLMs built on a CT-CLIP encoder. Using our novel framework, we found that lexical NLG metrics are highly sensitive to stylistic variations; GREEN Score aligns best with expert judgments (Spearman~0.70), while CRG shows negative correlation; and BERTScore-F1 is least sensitive to factual error injection. We will release the framework, code, and allowable portion of the anonymized evaluation data (rephrased/error-injected CT reports), to facilitate reproducible benchmarking and future metric development.
2.8CVMar 2
Robust White Blood Cell Classification with Stain-Normalized Decoupled Learning and EnsemblingLuu Le, Hoang-Loc Cao, Ha-Hieu Pham et al.
White blood cell (WBC) classification is fundamental for hematology applications such as infection assessment, leukemia screening, and treatment monitoring. However, real-world WBC datasets present substantial appearance variations caused by staining and scanning conditions, as well as severe class imbalance in which common cell types dominate while rare but clinically important categories are underrepresented. To address these challenges, we propose a stain-normalized, decoupled training framework that first learns transferable representations using instance-balanced sampling, and then rebalances the classifier with class-aware sampling and a hybrid loss combining effective-number weighting and focal modulation. In inference stage, we further enhance robustness by ensembling various trained backbones with test-time augmentation. Our approach achieved the top rank on the leaderboard of the WBCBench 2026: Robust White Blood Cell Classification Challenge at ISBI 2026.
1.5CVJan 21
Scribble-Supervised Medical Image Segmentation with Dynamic Teacher Switching and Hierarchical ConsistencyThanh-Huy Nguyen, Hoang-Loc Cao, Dat T. Chung et al.
Scribble-supervised methods have emerged to mitigate the prohibitive annotation burden in medical image segmentation. However, the inherent sparsity of these annotations introduces significant ambiguity, which results in noisy pseudo-label propagation and hinders the learning of robust anatomical boundaries. To address this challenge, we propose SDT-Net, a novel dual-teacher, single-student framework designed to maximize supervision quality from these weak signals. Our method features a Dynamic Teacher Switching (DTS) module to adaptively select the most reliable teacher. This selected teacher then guides the student via two synergistic mechanisms: high-confidence pseudo-labels, refined by a Pick Reliable Pixels (PRP) mechanism, and multi-level feature alignment, enforced by a Hierarchical Consistency (HiCo) module. Extensive experiments on the ACDC and MSCMRseg datasets demonstrate that SDT-Net achieves state-of-the-art performance, producing more accurate and anatomically plausible segmentation.
2.8CVJan 23
Domain-invariant Mixed-domain Semi-supervised Medical Image Segmentation with Clustered Maximum Mean Discrepancy AlignmentBa-Thinh Lam, Thanh-Huy Nguyen, Hoang-Thien Nguyen et al.
Deep learning has shown remarkable progress in medical image semantic segmentation, yet its success heavily depends on large-scale expert annotations and consistent data distributions. In practice, annotations are scarce, and images are collected from multiple scanners or centers, leading to mixed-domain settings with unknown domain labels and severe domain gaps. Existing semi-supervised or domain adaptation approaches typically assume either a single domain shift or access to explicit domain indices, which rarely hold in real-world deployment. In this paper, we propose a domain-invariant mixed-domain semi-supervised segmentation framework that jointly enhances data diversity and mitigates domain bias. A Copy-Paste Mechanism (CPM) augments the training set by transferring informative regions across domains, while a Cluster Maximum Mean Discrepancy (CMMD) block clusters unlabeled features and aligns them with labeled anchors via an MMD objective, encouraging domain-invariant representations. Integrated within a teacher-student framework, our method achieves robust and precise segmentation even with very few labeled examples and multiple unknown domain discrepancies. Experiments on Fundus and M&Ms benchmarks demonstrate that our approach consistently surpasses semi-supervised and domain adaptation methods, establishing a potential solution for mixed-domain semi-supervised medical image segmentation.
10.7CVMar 2, 2017
TumorNet: Lung Nodule Characterization Using Multi-View Convolutional Neural Network with Gaussian ProcessSarfaraz Hussein, Robert Gillies, Kunlin Cao et al.
Characterization of lung nodules as benign or malignant is one of the most important tasks in lung cancer diagnosis, staging and treatment planning. While the variation in the appearance of the nodules remains large, there is a need for a fast and robust computer aided system. In this work, we propose an end-to-end trainable multi-view deep Convolutional Neural Network (CNN) for nodule characterization. First, we use median intensity projection to obtain a 2D patch corresponding to each dimension. The three images are then concatenated to form a tensor, where the images serve as different channels of the input image. In order to increase the number of training samples, we perform data augmentation by scaling, rotating and adding noise to the input image. The trained network is used to extract features from the input image followed by a Gaussian Process (GP) regression to obtain the malignancy score. We also empirically establish the significance of different high level nodule attributes such as calcification, sphericity and others for malignancy determination. These attributes are found to be complementary to the deep multi-view CNN features and a significant improvement over other methods is obtained.