Georgiana Neag

CV
h-index10
3papers
7citations
Novelty35%
AI Score19

3 Papers

IVDec 9, 2022
Noise2Contrast: Multi-Contrast Fusion Enables Self-Supervised Tomographic Image Denoising

Fabian Wagner, Mareike Thies, Laura Pfaff et al.

Self-supervised image denoising techniques emerged as convenient methods that allow training denoising models without requiring ground-truth noise-free data. Existing methods usually optimize loss metrics that are calculated from multiple noisy realizations of similar images, e.g., from neighboring tomographic slices. However, those approaches fail to utilize the multiple contrasts that are routinely acquired in medical imaging modalities like MRI or dual-energy CT. In this work, we propose the new self-supervised training scheme Noise2Contrast that combines information from multiple measured image contrasts to train a denoising model. We stack denoising with domain-transfer operators to utilize the independent noise realizations of different image contrasts to derive a self-supervised loss. The trained denoising operator achieves convincing quantitative and qualitative results, outperforming state-of-the-art self-supervised methods by 4.7-11.0%/4.8-7.3% (PSNR/SSIM) on brain MRI data and by 43.6-50.5%/57.1-77.1% (PSNR/SSIM) on dual-energy CT X-ray microscopy data with respect to the noisy baseline. Our experiments on different real measured data sets indicate that Noise2Contrast training generalizes to other multi-contrast imaging modalities.

CVMar 1, 2023
Exploring Epipolar Consistency Conditions for Rigid Motion Compensation in In-vivo X-ray Microscopy

Mareike Thies, Fabian Wagner, Mingxuan Gu et al.

Intravital X-ray microscopy (XRM) in preclinical mouse models is of vital importance for the identification of microscopic structural pathological changes in the bone which are characteristic of osteoporosis. The complexity of this method stems from the requirement for high-quality 3D reconstructions of the murine bones. However, respiratory motion and muscle relaxation lead to inconsistencies in the projection data which result in artifacts in uncompensated reconstructions. Motion compensation using epipolar consistency conditions (ECC) has previously shown good performance in clinical CT settings. Here, we explore whether such algorithms are suitable for correcting motion-corrupted XRM data. Different rigid motion patterns are simulated and the quality of the motion-compensated reconstructions is assessed. The method is able to restore microscopic features for out-of-plane motion, but artifacts remain for more realistic motion patterns including all six degrees of freedom of rigid motion. Therefore, ECC is valuable for the initial alignment of the projection data followed by further fine-tuning of motion parameters using a reconstruction-based method.

CVApr 23, 2024
BigReg: An Efficient Registration Pipeline for High-Resolution X-Ray and Light-Sheet Fluorescence Microscopy

Siyuan Mei, Fuxin Fan, Mareike Thies et al.

Recently, X-ray microscopy (XRM) and light-sheet fluorescence microscopy (LSFM) have emerged as pivotal tools in preclinical research, particularly for studying bone remodeling diseases such as osteoporosis. These modalities offer micrometer-level resolution, and their integration allows for a complementary examination of bone microstructures which is essential for analyzing functional changes. However, registering high-resolution volumes from these independently scanned modalities poses substantial challenges, especially in real-world and reference-free scenarios. This paper presents BigReg, a fast, two-stage pipeline designed for large-volume registration of XRM and LSFM data. The first stage involves extracting surface features and applying two successive point cloud-based methods for coarse alignment. The subsequent stage refines this alignment using a modified cross-correlation technique, achieving precise volumetric registration. Evaluations using expert-annotated landmarks and augmented test data demonstrate that BigReg approaches the accuracy of landmark-based registration with a landmark distance (LMD) of 8.36\,\textmu m\,$\pm$\,0.12\,\textmu m and a landmark fitness (LM fitness) of 85.71\%\,$\pm$\,1.02\%. Moreover, BigReg can provide an optimal initialization for mutual information-based methods which otherwise fail independently, further reducing LMD to 7.24\,\textmu m\,$\pm$\,0.11\,\textmu m and increasing LM fitness to 93.90\%\,$\pm$\,0.77\%. Ultimately, key microstructures, notably lacunae in XRM and bone cells in LSFM, are accurately aligned, enabling unprecedented insights into the pathology of osteoporosis.