Haiming Zhu

IV
h-index2
4papers
16citations
Novelty50%
AI Score27

4 Papers

6.6IVMar 20, 2022
Soft-CP: A Credible and Effective Data Augmentation for Semantic Segmentation of Medical Lesions

Pingping Dai, Licong Dong, Ruihan Zhang et al.

The medical datasets are usually faced with the problem of scarcity and data imbalance. Moreover, annotating large datasets for semantic segmentation of medical lesions is domain-knowledge and time-consuming. In this paper, we propose a new object-blend method(short in soft-CP) that combines the Copy-Paste augmentation method for semantic segmentation of medical lesions offline, ensuring the correct edge information around the lession to solve the issue above-mentioned. We proved the method's validity with several datasets in different imaging modalities. In our experiments on the KiTS19[2] dataset, Soft-CP outperforms existing medical lesions synthesis approaches. The Soft-CP augementation provides gains of +26.5% DSC in the low data regime(10% of data) and +10.2% DSC in the high data regime(all of data), In offline training data, the ratio of real images to synthetic images is 3:1.

2.7IVApr 22, 2022
MIPR:Automatic Annotation of Medical Images with Pixel Rearrangement

Pingping Dai, Haiming Zhu, Shuang Ge et al.

Most of the state-of-the-art semantic segmentation reported in recent years is based on fully supervised deep learning in the medical domain. How?ever, the high-quality annotated datasets require intense labor and domain knowledge, consuming enormous time and cost. Previous works that adopt semi?supervised and unsupervised learning are proposed to address the lack of anno?tated data through assisted training with unlabeled data and achieve good perfor?mance. Still, these methods can not directly get the image annotation as doctors do. In this paper, inspired by self-training of semi-supervised learning, we pro?pose a novel approach to solve the lack of annotated data from another angle, called medical image pixel rearrangement (short in MIPR). The MIPR combines image-editing and pseudo-label technology to obtain labeled data. As the number of iterations increases, the edited image is similar to the original image, and the labeled result is similar to the doctor annotation. Therefore, the MIPR is to get labeled pairs of data directly from amounts of unlabled data with pixel rearrange?ment, which is implemented with a designed conditional Generative Adversarial Networks and a segmentation network. Experiments on the ISIC18 show that the effect of the data annotated by our method for segmentation task is is equal to or even better than that of doctors annotations

2.3MED-PHApr 15, 2025
Embedding Radiomics into Vision Transformers for Multimodal Medical Image Classification

Zhenyu Yang, Haiming Zhu, Rihui Zhang et al.

Background: Deep learning has significantly advanced medical image analysis, with Vision Transformers (ViTs) offering a powerful alternative to convolutional models by modeling long-range dependencies through self-attention. However, ViTs are inherently data-intensive and lack domain-specific inductive biases, limiting their applicability in medical imaging. In contrast, radiomics provides interpretable, handcrafted descriptors of tissue heterogeneity but suffers from limited scalability and integration into end-to-end learning frameworks. In this work, we propose the Radiomics-Embedded Vision Transformer (RE-ViT) that combines radiomic features with data-driven visual embeddings within a ViT backbone. Purpose: To develop a hybrid RE-ViT framework that integrates radiomics and patch-wise ViT embeddings through early fusion, enhancing robustness and performance in medical image classification. Methods: Following the standard ViT pipeline, images were divided into patches. For each patch, handcrafted radiomic features were extracted and fused with linearly projected pixel embeddings. The fused representations were normalized, positionally encoded, and passed to the ViT encoder. A learnable [CLS] token aggregated patch-level information for classification. We evaluated RE-ViT on three public datasets (including BUSI, ChestXray2017, and Retinal OCT) using accuracy, macro AUC, sensitivity, and specificity. RE-ViT was benchmarked against CNN-based (VGG-16, ResNet) and hybrid (TransMed) models. Results: RE-ViT achieved state-of-the-art results: on BUSI, AUC=0.950+/-0.011; on ChestXray2017, AUC=0.989+/-0.004; on Retinal OCT, AUC=0.986+/-0.001, which outperforms other comparison models. Conclusions: The RE-ViT framework effectively integrates radiomics with ViT architectures, demonstrating improved performance and generalizability across multimodal medical image classification tasks.

3.7CVFeb 19, 2024
Zero-Shot Video Translation via Token Warping

Haiming Zhu, Yangyang Xu, Jun Yu et al.

With the revolution of generative AI, video-related tasks have been widely studied. However, current state-of-the-art video models still lag behind image models in visual quality and user control over generated content. In this paper, we introduce TokenWarping, a novel framework for temporally coherent video translation. Existing diffusion-based video editing approaches rely solely on key and value patches in self-attention to ensure temporal consistency, often sacrificing the preservation of local and structural regions. Critically, these methods overlook the significance of the query patches in achieving accurate feature aggregation and temporal coherence. In contrast, TokenWarping leverages complementary token priors by constructing temporal correlations across different frames. Our method begins by extracting optical flows from source videos. During the denoising process of the diffusion model, these optical flows are used to warp the previous frame's query, key, and value patches, aligning them with the current frame's patches. By directly warping the query patches, we enhance feature aggregation in self-attention, while warping the key and value patches ensures temporal consistency across frames. This token warping imposes explicit constraints on the self-attention layer outputs, effectively ensuring temporally coherent translation. Our framework does not require any additional training or fine-tuning and can be seamlessly integrated with existing text-to-image editing methods. We conduct extensive experiments on various video translation tasks, demonstrating that TokenWarping surpasses state-of-the-art methods both qualitatively and quantitatively. Video demonstrations are available in supplementary materials.