17.8AIJun 30, 2023
Transformers in Healthcare: A SurveySubhash Nerella, Sabyasachi Bandyopadhyay, Jiaqing Zhang et al.
With Artificial Intelligence (AI) increasingly permeating various aspects of society, including healthcare, the adoption of the Transformers neural network architecture is rapidly changing many applications. Transformer is a type of deep learning architecture initially developed to solve general-purpose Natural Language Processing (NLP) tasks and has subsequently been adapted in many fields, including healthcare. In this survey paper, we provide an overview of how this architecture has been adopted to analyze various forms of data, including medical imaging, structured and unstructured Electronic Health Records (EHR), social media, physiological signals, and biomolecular sequences. Those models could help in clinical diagnosis, report generation, data reconstruction, and drug/protein synthesis. We identified relevant studies using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We also discuss the benefits and limitations of using transformers in healthcare and examine issues such as computational cost, model interpretability, fairness, alignment with human values, ethical implications, and environmental impact.
2.0LGMar 11, 2023
Predicting risk of delirium from ambient noise and light information in the ICUSabyasachi Bandyopadhyay, Ahna Cecil, Jessica Sena et al.
Existing Intensive Care Unit (ICU) delirium prediction models do not consider environmental factors despite strong evidence of their influence on delirium. This study reports the first deep-learning based delirium prediction model for ICU patients using only ambient noise and light information. Ambient light and noise intensities were measured from ICU rooms of 102 patients from May 2021 to September 2022 using Thunderboard, ActiGraph sensors and an iPod with AudioTools application. These measurements were divided into daytime (0700 to 1859) and nighttime (1900 to 0659). Deep learning models were trained using this data to predict the incidence of delirium during ICU stay or within 4 days of discharge. Finally, outcome scores were analyzed to evaluate the importance and directionality of every feature. Daytime noise levels were significantly higher than nighttime noise levels. When using only noise features or a combination of noise and light features 1-D convolutional neural networks (CNN) achieved the strongest performance: AUC=0.77, 0.74; Sensitivity=0.60, 0.56; Specificity=0.74, 0.74; Precision=0.46, 0.40 respectively. Using only light features, Long Short-Term Memory (LSTM) networks performed best: AUC=0.80, Sensitivity=0.60, Specificity=0.77, Precision=0.37. Maximum nighttime and minimum daytime noise levels were the strongest positive and negative predictors of delirium respectively. Nighttime light level was a stronger predictor of delirium than daytime light level. Total influence of light features outweighed that of noise features on the second and fourth day of ICU stay. This study shows that ambient light and noise intensities are strong predictors of long-term delirium incidence in the ICU. It reveals that daytime and nighttime environmental factors might influence delirium differently and that the importance of light and noise levels vary over the course of an ICU stay.
2.0LGNov 3, 2023
The Potential of Wearable Sensors for Assessing Patient Acuity in Intensive Care Unit (ICU)Jessica Sena, Mohammad Tahsin Mostafiz, Jiaqing Zhang et al.
Acuity assessments are vital in critical care settings to provide timely interventions and fair resource allocation. Traditional acuity scores rely on manual assessments and documentation of physiological states, which can be time-consuming, intermittent, and difficult to use for healthcare providers. Furthermore, such scores do not incorporate granular information such as patients' mobility level, which can indicate recovery or deterioration in the ICU. We hypothesized that existing acuity scores could be potentially improved by employing Artificial Intelligence (AI) techniques in conjunction with Electronic Health Records (EHR) and wearable sensor data. In this study, we evaluated the impact of integrating mobility data collected from wrist-worn accelerometers with clinical data obtained from EHR for developing an AI-driven acuity assessment score. Accelerometry data were collected from 86 patients wearing accelerometers on their wrists in an academic hospital setting. The data was analyzed using five deep neural network models: VGG, ResNet, MobileNet, SqueezeNet, and a custom Transformer network. These models outperformed a rule-based clinical score (SOFA= Sequential Organ Failure Assessment) used as a baseline, particularly regarding the precision, sensitivity, and F1 score. The results showed that while a model relying solely on accelerometer data achieved limited performance (AUC 0.50, Precision 0.61, and F1-score 0.68), including demographic information with the accelerometer data led to a notable enhancement in performance (AUC 0.69, Precision 0.75, and F1-score 0.67). This work shows that the combination of mobility and patient information can successfully differentiate between stable and unstable states in critically ill patients.
6.5CVMay 11
Auditing Multimodal LLM Raters: Central Tendency Bias in Clinical Ordinal ScoringJiaqing Zhang, Sandeep Elluri, Bhanu Cherukuvada et al.
Multimodal large language models (LLMs) are increasingly explored as automated evaluators in clinical settings, yet their scoring behavior on ordinal clinical scales remains poorly understood. We benchmark three frontier LLM families against supervised deep learning models for scoring Clock Drawing Test (CDT) images on two public datasets using the Shulman rubric. While fully fine-tuned Vision Transformers achieve the best calibration (MAE 0.52, within-1 accuracy 91%), zero-shot LLMs remain competitive on tolerance-based agreement (GPT-5 MAE 0.67, within-1 accuracy 92%) despite higher absolute error. However, per-score analysis reveals that all three LLM families exhibit a pronounced central tendency effect (systematic endpoint compression): predictions are systematically compressed toward the middle of the scale, with over-prediction at the low end (score 0 to 1) and under-prediction at the high end (score 5 to 4). This effect disproportionately affects the clinically critical extremes where accurate scoring most impacts screening decisions for cognitive impairment. Targeted ablations show that neither few-shot exemplars spanning the full score range nor removing clinical terminology from the prompt eliminates the effect. Our findings extend the LLM-as-a-judge bias literature from NLP evaluation to clinical assessment, and highlight the need for calibration-aware evaluation and post-hoc calibration before deploying LLM-based raters in high-stakes screening workflows.
6.9LGJun 17
Risk Stratification for ICU Delirium using Pervasive Ambient Sensing InformationJiaqing Zhang, Sabyasachi Bandyopadhyay, Miguel Contreras et al.
Delirium is a common and serious complication in the Intensive Care Unit (ICU), associated with increased morbidity, prolonged hospital stays, and higher healthcare costs. Despite its prevalence, early prediction and prevention remain challenging. Environmental factors such as ambient sound and light may influence the onset of delirium, yet they are often overlooked in risk assessments. In this study, we examined whether light intensity and sound pressure levels can independently predict delirium across multiple prediction horizons. We evaluated four efficient sequential neural network models on data collected from 9 ICUs across 309 patients to predict delirium for 10 prediction-window sizes. We reported feature importance and direction of influence using Shapley Additive Explanations analysis. The convolutional model achieved the strongest discrimination, with AUC = 0.80 on sound data and on combined data. Sound features were the dominant predictors overall. Integrating sound with light improved short-term ($<1$ week) prediction, with the combined model assigning the highest risk immediately after the sensing period. These findings suggest that passive ambient sensing, especially sound, can add a clinically meaningful, interpretable signal for delirium risk estimation and offer a practical pathway to enrich multimodal ICU prediction and prevention strategies.
2.3SPDec 13, 2024
MANGO: Multimodal Acuity traNsformer for intelliGent ICU OutcomesJiaqing Zhang, Miguel Contreras, Sabyasachi Bandyopadhyay et al.
Estimation of patient acuity in the Intensive Care Unit (ICU) is vital to ensure timely and appropriate interventions. Advances in artificial intelligence (AI) technologies have significantly improved the accuracy of acuity predictions. However, prior studies using machine learning for acuity prediction have predominantly relied on electronic health records (EHR) data, often overlooking other critical aspects of ICU stay, such as patient mobility, environmental factors, and facial cues indicating pain or agitation. To address this gap, we present MANGO: the Multimodal Acuity traNsformer for intelliGent ICU Outcomes, designed to enhance the prediction of patient acuity states, transitions, and the need for life-sustaining therapy. We collected a multimodal dataset ICU-Multimodal, incorporating four key modalities, EHR data, wearable sensor data, video of patient's facial cues, and ambient sensor data, which we utilized to train MANGO. The MANGO model employs a multimodal feature fusion network powered by Transformer masked self-attention method, enabling it to capture and learn complex interactions across these diverse data modalities even when some modalities are absent. Our results demonstrated that integrating multiple modalities significantly improved the model's ability to predict acuity status, transitions, and the need for life-sustaining therapy. The best-performing models achieved an area under the receiver operating characteristic curve (AUROC) of 0.76 (95% CI: 0.72-0.79) for predicting transitions in acuity status and the need for life-sustaining therapy, while 0.82 (95% CI: 0.69-0.89) for acuity status prediction...
SkeleMotion: A New Representation of Skeleton Joint Sequences Based on Motion Information for 3D Action RecognitionCarlos Caetano, Jessica Sena, François Brémond et al.
Due to the availability of large-scale skeleton datasets, 3D human action recognition has recently called the attention of computer vision community. Many works have focused on encoding skeleton data as skeleton image representations based on spatial structure of the skeleton joints, in which the temporal dynamics of the sequence is encoded as variations in columns and the spatial structure of each frame is represented as rows of a matrix. To further improve such representations, we introduce a novel skeleton image representation to be used as input of Convolutional Neural Networks (CNNs), named SkeleMotion. The proposed approach encodes the temporal dynamics by explicitly computing the magnitude and orientation values of the skeleton joints. Different temporal scales are employed to compute motion values to aggregate more temporal dynamics to the representation making it able to capture longrange joint interactions involved in actions as well as filtering noisy motion values. Experimental results demonstrate the effectiveness of the proposed representation on 3D action recognition outperforming the state-of-the-art on NTU RGB+D 120 dataset.
Human Activity Recognition Based on Wearable Sensor Data: A Standardization of the State-of-the-ArtArtur Jordao, Antonio C. Nazare, Jessica Sena et al.
Human activity recognition based on wearable sensor data has been an attractive research topic due to its application in areas such as healthcare and smart environments. In this context, many works have presented remarkable results using accelerometer, gyroscope and magnetometer data to represent the activities categories. However, current studies do not consider important issues that lead to skewed results, making it hard to assess the quality of sensor-based human activity recognition and preventing a direct comparison of previous works. These issues include the samples generation processes and the validation protocols used. We emphasize that in other research areas, such as image classification and object detection, these issues are already well-defined, which brings more efforts towards the application. Inspired by this, we conduct an extensive set of experiments that analyze different sample generation processes and validation protocols to indicate the vulnerable points in human activity recognition based on wearable sensor data. For this purpose, we implement and evaluate several top-performance methods, ranging from handcrafted-based approaches to convolutional neural networks. According to our study, most of the experimental evaluations that are currently employed are not adequate to perform the activity recognition in the context of wearable sensor data, in which the recognition accuracy drops considerably when compared to an appropriate evaluation approach. To the best of our knowledge, this is the first study that tackles essential issues that compromise the understanding of the performance in human activity recognition based on wearable sensor data.
0.9CVJun 8, 2018
A Content-Based Late Fusion Approach Applied to Pedestrian DetectionJessica Sena, Artur Jordao, William Robson Schwartz
The variety of pedestrians detectors proposed in recent years has encouraged some works to fuse pedestrian detectors to achieve a more accurate detection. The intuition behind is to combine the detectors based on its spatial consensus. We propose a novel method called Content-Based Spatial Consensus (CSBC), which, in addition to relying on spatial consensus, considers the content of the detection windows to learn a weighted-fusion of pedestrian detectors. The result is a reduction in false alarms and an enhancement in the detection. In this work, we also demonstrate that there is small influence of the feature used to learn the contents of the windows of each detector, which enables our method to be efficient even employing simple features. The CSBC overcomes state-of-the-art fusion methods in the ETH dataset and in the Caltech dataset. Particularly, our method is more efficient since fewer detectors are necessary to achieve expressive results.