3.2LGJul 6
Video-based detection of cessation of breathing in pre-term infants using machine learningDineo Serame, Lionel Tarassenko, Mauricio Villarroel
Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control. However, reliable respiratory monitoring in the neonatal intensive care unit (NICU) remains challenging because motion artefacts, sensor displacement, and skin fragility can compromise contact-based measurements. Non-contact video monitoring offers a complementary approach that does not depend on adhesive sensors while providing additional respiratory information. We investigated whether camera-based signals can detect apnoea-related cessation of breathing (COBE) and provide complementary information to routinely acquired physiological signals. Using video and clinical recordings from 30 pre-term infants, respiratory motion was extracted from dynamically tracked torso regions to generate camera-derived time-series signals. Camera-only models were trained using residual network (ResNet) architectures, while hybrid models combined video-derived signals with impedance pneumography (IP), ECG-derived respiration (EDR), and the PPG-derived respiratory envelope. Camera-only models achieved a balanced accuracy of 76.9%, demonstrating the feasibility of non-contact COBE detection. Combining video-derived features with IP improved balanced accuracy to 90.6%, outperforming either modality alone and indicating that video provides respiratory information beyond standard physiological signals. These findings show that video-derived signals contain clinically relevant respiratory features and enhance COBE detection when combined with conventional physiological signals. This supports non-contact video as a complementary modality for automated COBE detection and highlights its potential to improve the robustness of neonatal respiratory monitoring.
7.7SPMay 26
Motif-based morphology signatures for interpretable ECG screening and monitoringNivedita Bijlani, Mauricio Villarroel
Electrocardiography (ECG) remains central to cardiovascular screening, yet interpretation remains largely manual and episodic. Clinical practice relies on brief resting ECGs and, when required, long-duration ambulatory recordings, both generating data that require resource-intensive review. Consequently, subtle morphological changes or progressive drift preceding clinically apparent abnormalities may go unnoticed. We propose a motif-based framework that defines beat-aligned ECG motifs as interpretable cardiac signatures and quantifies morphological drift and deviation across short and long-term monitoring. Motifs are representative cardiac cycles capturing dominant morphology. We introduce three interpretable drift metrics: deviation from a normal sinus rhythm (NSR), deviation from a personalised baseline, and a motif instability index. Motifs are extracted by selecting beats that minimise Dynamic Time Warping (DTW) distance within fixed windows. We evaluate these metrics on short (PTB-XL) and long-duration (MIT-BIH Arrhythmia) ECG datasets. Interpretability is achieved through representative motif overlays and fiducial-based visualisations, enabling direct inspection of morphological changes. In MIT-BIH, the proposed metrics significantly separated predominantly normal from arrhythmic subjects (p<0.01). In PTB-XL, NSR deviation distinguished normal from abnormal ECGs across major diagnostic subtypes (p<1e-4, Cliff's delta up to 0.93). ECG motifs provide an interpretable representation of cardiac morphology, supporting scalable longitudinal monitoring and early detection of morphology-driven change.
2.7LGJun 22
Deep learning-based detection of cessation of breathing in pre-term infantsDineo Serame, Lionel Tarassenko, Mauricio Villarroel
Apnoea of prematurity is characterised by recurrent episodes of cessation of breathing and remains difficult to detect reliably using routinely monitored physiological signals in the Neonatal Intensive Care Unit (NICU). Existing bedside monitors rely primarily on respiratory rate and oxygen saturation thresholds, often generating high false-positive alarm rates and missing short or irregular events. Improving automated detection using routinely acquired clinical signals could enhance identification of clinically meaningful events without additional sensing hardware. We evaluated deep learning-based detection of apnoea-related Cessation Of BrEathing (COBE) events using impedance pneumography (IP), electrocardiography (ECG), and photoplethysmography (PPG) signals from approximately 430 hours of NICU recordings collected from 24 pre-term infants. Three independent reviewers annotated COBE events, producing a dataset of 346 COBE and 608 non-COBE events. We compared a shallow convolutional neural network (CNN), residual networks (ResNets), and a ConvNeXt architecture using an independent held-out test set. Across all architectures, detection performance was influenced more strongly by signal modality than by architectural complexity. Unimodal IP-based models achieved balanced accuracies of 86.8-88.0%, outperforming ECG-derived (62.6-69.7%) and PPG-derived (65.1-66.4%) respiratory surrogates. Multimodal fusion yielded modest improvements over IP alone. The best-performing model, a ConvNeXt architecture combining IP and PPG inputs, achieved 88.7% balanced accuracy and an F1 score of 0.75 on the independent test set. These findings demonstrate that deep learning models applied to routinely monitored NICU signals can reliably detect COBE events and highlight the importance of signal modality in data-constrained neonatal monitoring settings.
0.6CVJun 18
InfantFace: Detecting infant faces in neonatal clinical environmentsAbdullah Bin-Obaid, Maria M. Cobo, Rebeccah Slater et al.
Reliable localisation of the neonatal face is the first step for several video-camera based non-contact assessments such as pain and distress related facial expression analysis, pain scoring, cardiorespiratory signal extraction and cessation of breathing alerts. However, major challenges persist in neonatal clinical environments. Cluttered backgrounds, illumination changes and poor lighting conditions can reduce the accuracy of face detection models. Clinical interventions, monitoring equipment and, in some cases, medical devices can obstruct the face, making visual assessment difficult. We propose a one-stage YOLOv11m-based model tailored for face detection of infants in neonatal clinical environments. We combined multiple publicly available datasets (VGGFace2, CelebA, FDDB, WIDER FACE) to train and evaluate our proposed model. We then fine-tuned our model on a neonatal research dataset involving 228 videos from 114 recording sessions of 113 independent infants. Before fine-tuning, our model achieved an AP50 of 0.87, surpassing the performance of three state-of-the-art general face detectors. Performance improved further to an AP50 of 0.96 after clinical-domain adaptation. Evaluating face detection performance across different datasets remains a challenge due to the lack of publicly available neonatal datasets. Prioritising the creation of such datasets, while upholding appropriate privacy safeguards and ethical standards in their creation and use, would greatly support further progress in this field.
3.8CVJun 18
NeoLoc-68: End-to-end 68-point neonatal facial landmark localisation in neonatal clinical environmentsAbdullah Bin-Obaid, Maria M. Cobo, Rebeccah Slater et al.
Facial landmark localisation is a prerequisite for developing automated, non-contact neonatal pain assessment methods. Clinicians use pain scales to judge the severity of pain, many of which rely on facial expression. However, facial landmark detectors trained on adult faces perform poorly in neonatal clinical environments due to frequent occlusions caused by medical equipment, varied head poses, and challenging imaging conditions, including motion blur triggered by sudden pain-related movements. We propose an end-to-end facial landmark detector capable of predicting 68 landmarks on neonatal faces in clinical environments. We combined 37,459 single-face images from 11 public datasets, standardised to 68-point markup, with 1,123 manually annotated frames from a neonatal research dataset (totalling over 76,000 landmarks). A YOLO-based keypoint model was adapted to regress the facial landmarks, initialised with weights from a pretrained neonatal face detector. On public datasets, our proposed model achieved state-of-the-art performance: Normalised Mean Error (NME) = 5.37, Failure Rate (FR) = 12.5%, Area Under the Cumulative Error Curve (AUC) at AUC0.08 = 38.00% and AUC0.1 = 48.70%. On the clinical neonatal test set, before fine-tuning, the model achieved the lowest Detection Failure Rate (DFR) = 5.3% among all baselines and showed strong generalisation. After fine-tuning, performance improved further to NME = 6.36, FR = 22.30%, DFR = 1.77%, AUC0.08 = 29.24% and AUC0.1 = 40.25%. To the best of our knowledge, this represents the first end-to-end 68-point neonatal facial landmark detection model. With further dataset expansion and refinement, it could support downstream tasks in neonatal health monitoring and pain-related facial analysis.