Sho Ozaki

h-index7
2papers
230citations

2 Papers

2.0CVAug 6, 2024
Iterative CT Reconstruction via Latent Variable Optimization of Shallow Diffusion Models

Sho Ozaki, Shizuo Kaji, Toshikazu Imae et al.

Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we proposed a novel computed tomography (CT) reconstruction method by combining the denoising diffusion probabilistic model with iterative CT reconstruction. In sharp contrast to previous studies, we optimized the fidelity loss of CT reconstruction with respect to the latent variable of the diffusion model, instead of the image and model parameters. To suppress the changes in anatomical structures produced by the diffusion model, we shallowed the diffusion and reverse processes and fixed a set of added noises in the reverse process to make it deterministic during the inference. We demonstrated the effectiveness of the proposed method through the sparse-projection CT reconstruction of 1/10 projection data. Despite the simplicity of the implementation, the proposed method has the potential to reconstruct high-quality images while preserving the patient's anatomical structures and was found to outperform existing methods, including iterative reconstruction, iterative reconstruction with total variation, and the diffusion model alone in terms of quantitative indices such as the structural similarity index and peak signal-to-noise ratio. We also explored further sparse-projection CT reconstruction using 1/20 projection data with the same trained diffusion model. As the number of iterations increased, the image quality improved comparable to that of 1/10 sparse-projection CT reconstruction. In principle, this method can be widely applied not only to CT but also to other imaging modalities.

8.1CVJan 17, 2019Code
Visual enhancement of Cone-beam CT by use of CycleGAN

S. Kida, S. Kaji, K. Nawa et al.

Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for image-guided radiation therapy, extracting radiomic information for designing patient-specific treatment, and computing fractional dose distributions for adaptive radiation therapy. However, CBCT images suffer from low soft-tissue contrast, noise, and artifacts compared to conventional fan-beam CT images. Therefore, it is essential to improve the image quality of CBCT. In this paper, we propose a synthetic approach to translate CBCT images with deep neural networks. Our method requires only unpaired and unaligned CBCT images and planning fan-beam CT (PlanCT) images for training. Once trained, 3D reconstructed CBCT images can be directly translated to high-quality PlanCT-like images. We demonstrate the effectiveness of our method with images obtained from 24 prostate patients, and we provide a statistical and visual comparison. The image quality of the translated images shows substantial improvement in voxel values, spatial uniformity, and artifact suppression compared to those of the original CBCT. The anatomical structures of the original CBCT images were also well preserved in the translated images. Our method enables more accurate adaptive radiation therapy, and opens up new applications for CBCT that hinge on high-quality images.