2.3GNOct 12, 2023
Multi-View Variational Autoencoder for Missing Value Imputation in Untargeted MetabolomicsChen Zhao, Kuan-Jui Su, Chong Wu et al.
Background: Missing data is a common challenge in mass spectrometry-based metabolomics, which can lead to biased and incomplete analyses. The integration of whole-genome sequencing (WGS) data with metabolomics data has emerged as a promising approach to enhance the accuracy of data imputation in metabolomics studies. Method: In this study, we propose a novel method that leverages the information from WGS data and reference metabolites to impute unknown metabolites. Our approach utilizes a multi-view variational autoencoder to jointly model the burden score, polygenetic risk score (PGS), and linkage disequilibrium (LD) pruned single nucleotide polymorphisms (SNPs) for feature extraction and missing metabolomics data imputation. By learning the latent representations of both omics data, our method can effectively impute missing metabolomics values based on genomic information. Results: We evaluate the performance of our method on empirical metabolomics datasets with missing values and demonstrate its superiority compared to conventional imputation techniques. Using 35 template metabolites derived burden scores, PGS and LD-pruned SNPs, the proposed methods achieved R^2-scores > 0.01 for 71.55% of metabolites. Conclusion: The integration of WGS data in metabolomics imputation not only improves data completeness but also enhances downstream analyses, paving the way for more comprehensive and accurate investigations of metabolic pathways and disease associations. Our findings offer valuable insights into the potential benefits of utilizing WGS data for metabolomics data imputation and underscore the importance of leveraging multi-modal data integration in precision medicine research.
3.6CVApr 21, 2025
ICGM-FRAX: Iterative Cross Graph Matching for Hip Fracture Risk Assessment using Dual-energy X-ray Absorptiometry ImagesChen Zhao, Anjum Shaik, Joyce H. Keyak et al.
Hip fractures represent a major health concern, particularly among the elderly, often leading decreased mobility and increased mortality. Early and accurate detection of at risk individuals is crucial for effective intervention. In this study, we propose Iterative Cross Graph Matching for Hip Fracture Risk Assessment (ICGM-FRAX), a novel approach for predicting hip fractures using Dual-energy X-ray Absorptiometry (DXA) images. ICGM-FRAX involves iteratively comparing a test (subject) graph with multiple template graphs representing the characteristics of hip fracture subjects to assess the similarity and accurately to predict hip fracture risk. These graphs are obtained as follows. The DXA images are separated into multiple regions of interest (RoIs), such as the femoral head, shaft, and lesser trochanter. Radiomic features are then calculated for each RoI, with the central coordinates used as nodes in a graph. The connectivity between nodes is established according to the Euclidean distance between these coordinates. This process transforms each DXA image into a graph, where each node represents a RoI, and edges derived by the centroids of RoIs capture the spatial relationships between them. If the test graph closely matches a set of template graphs representing subjects with incident hip fractures, it is classified as indicating high hip fracture risk. We evaluated our method using 547 subjects from the UK Biobank dataset, and experimental results show that ICGM-FRAX achieved a sensitivity of 0.9869, demonstrating high accuracy in predicting hip fractures.
7.1LGOct 16, 2025
An Advanced Two-Stage Model with High Sensitivity and Generalizability for Prediction of Hip Fracture Risk Using Multiple DatasetsShuo Sun, Meiling Zhou, Chen Zhao et al.
Hip fractures are a major cause of disability, mortality, and healthcare burden in older adults, underscoring the need for early risk assessment. However, commonly used tools such as the DXA T-score and FRAX often lack sensitivity and miss individuals at high risk, particularly those without prior fractures or with osteopenia. To address this limitation, we propose a sequential two-stage model that integrates clinical and imaging information to improve prediction accuracy. Using data from the Osteoporotic Fractures in Men Study (MrOS), the Study of Osteoporotic Fractures (SOF), and the UK Biobank, Stage 1 (Screening) employs clinical, demographic, and functional variables to estimate baseline risk, while Stage 2 (Imaging) incorporates DXA-derived features for refinement. The model was rigorously validated through internal and external testing, showing consistent performance and adaptability across cohorts. Compared to T-score and FRAX, the two-stage framework achieved higher sensitivity and reduced missed cases, offering a cost-effective and personalized approach for early hip fracture risk assessment. Keywords: Hip Fracture, Two-Stage Model, Risk Prediction, Sensitivity, DXA, FRAX