IVJul 31, 2024Code
Robust Simultaneous Multislice MRI Reconstruction Using Slice-Wise Learned Generative Diffusion PriorsShoujin Huang, Guanxiong Luo, Yunlin Zhao et al.
Simultaneous multislice (SMS) imaging is a powerful technique for accelerating magnetic resonance imaging (MRI) acquisitions. However, SMS reconstruction remains challenging due to complex signal interactions between and within the excited slices. In this study, we introduce ROGER, a robust SMS MRI reconstruction method based on deep generative priors. Utilizing denoising diffusion probabilistic models (DDPM), ROGER begins with Gaussian noise and gradually recovers individual slices through reverse diffusion iterations while enforcing data consistency from measured k-space data within the readout concatenation framework. The posterior sampling procedure is designed such that the DDPM training can be performed on single-slice images without requiring modifications for SMS tasks. Additionally, our method incorporates a low-frequency enhancement (LFE) module to address the practical issue that SMS-accelerated fast spin echo (FSE) and echo planar imaging (EPI) sequences cannot easily embed fully-sampled autocalibration signals. Extensive experiments on both retrospectively and prospectively accelerated datasets demonstrate that ROGER consistently outperforms existing methods, enhancing both anatomical and functional imaging with strong out-of-distribution generalization. The source code and sample data for ROGER are available at https://github.com/Solor-pikachu/ROGER.
IVMar 8, 2024Code
Noise Level Adaptive Diffusion Model for Robust Reconstruction of Accelerated MRIShoujin Huang, Guanxiong Luo, Xi Wang et al.
In general, diffusion model-based MRI reconstruction methods incrementally remove artificially added noise while imposing data consistency to reconstruct the underlying images. However, real-world MRI acquisitions already contain inherent noise due to thermal fluctuations. This phenomenon is particularly notable when using ultra-fast, high-resolution imaging sequences for advanced research, or using low-field systems favored by low- and middle-income countries. These common scenarios can lead to sub-optimal performance or complete failure of existing diffusion model-based reconstruction techniques. Specifically, as the artificially added noise is gradually removed, the inherent MRI noise becomes increasingly pronounced, making the actual noise level inconsistent with the predefined denoising schedule and consequently inaccurate image reconstruction. To tackle this problem, we propose a posterior sampling strategy with a novel NoIse Level Adaptive Data Consistency (Nila-DC) operation. Extensive experiments are conducted on two public datasets and an in-house clinical dataset with field strength ranging from 0.3T to 3T, showing that our method surpasses the state-of-the-art MRI reconstruction methods, and is highly robust against various noise levels. The code for Nila is available at https://github.com/Solor-pikachu/Nila.