Fuchen Zheng

CV
4papers
4citations
Novelty50%
AI Score50

4 Papers

5.2CVSep 12, 2024Code
Lagrange Duality and Compound Multi-Attention Transformer for Semi-Supervised Medical Image Segmentation

Fuchen Zheng, Quanjun Li, Weixuan Li et al.

Medical image segmentation, a critical application of semantic segmentation in healthcare, has seen significant advancements through specialized computer vision techniques. While deep learning-based medical image segmentation is essential for assisting in medical diagnosis, the lack of diverse training data causes the long-tail problem. Moreover, most previous hybrid CNN-ViT architectures have limited ability to combine various attentions in different layers of the Convolutional Neural Network. To address these issues, we propose a Lagrange Duality Consistency (LDC) Loss, integrated with Boundary-Aware Contrastive Loss, as the overall training objective for semi-supervised learning to mitigate the long-tail problem. Additionally, we introduce CMAformer, a novel network that synergizes the strengths of ResUNet and Transformer. The cross-attention block in CMAformer effectively integrates spatial attention and channel attention for multi-scale feature fusion. Overall, our results indicate that CMAformer, combined with the feature fusion framework and the new consistency loss, demonstrates strong complementarity in semi-supervised learning ensembles. We achieve state-of-the-art results on multiple public medical image datasets. Example code are available at: \url{https://github.com/lzeeorno/Lagrange-Duality-and-CMAformer}.

6.2CVDec 3, 2025Code
HBFormer: A Hybrid-Bridge Transformer for Microtumor and Miniature Organ Segmentation

Fuchen Zheng, Xinyi Chen, Weixuan Li et al.

Medical image segmentation is a cornerstone of modern clinical diagnostics. While Vision Transformers that leverage shifted window-based self-attention have established new benchmarks in this field, they are often hampered by a critical limitation: their localized attention mechanism struggles to effectively fuse local details with global context. This deficiency is particularly detrimental to challenging tasks such as the segmentation of microtumors and miniature organs, where both fine-grained boundary definition and broad contextual understanding are paramount. To address this gap, we propose HBFormer, a novel Hybrid-Bridge Transformer architecture. The 'Hybrid' design of HBFormer synergizes a classic U-shaped encoder-decoder framework with a powerful Swin Transformer backbone for robust hierarchical feature extraction. The core innovation lies in its 'Bridge' mechanism, a sophisticated nexus for multi-scale feature integration. This bridge is architecturally embodied by our novel Multi-Scale Feature Fusion (MFF) decoder. Departing from conventional symmetric designs, the MFF decoder is engineered to fuse multi-scale features from the encoder with global contextual information. It achieves this through a synergistic combination of channel and spatial attention modules, which are constructed from a series of dilated and depth-wise convolutions. These components work in concert to create a powerful feature bridge that explicitly captures long-range dependencies and refines object boundaries with exceptional precision. Comprehensive experiments on challenging medical image segmentation datasets, including multi-organ, liver tumor, and bladder tumor benchmarks, demonstrate that HBFormer achieves state-of-the-art results, showcasing its outstanding capabilities in microtumor and miniature organ segmentation. Code and models are available at: https://github.com/lzeeorno/HBFormer.

6.2CVNov 10, 2025Code
Adaptive Morph-Patch Transformer for Aortic Vessel Segmentation

Zhenxi Zhang, Fuchen Zheng, Adnan Iltaf et al.

Accurate segmentation of aortic vascular structures is critical for diagnosing and treating cardiovascular diseases.Traditional Transformer-based models have shown promise in this domain by capturing long-range dependencies between vascular features. However, their reliance on fixed-size rectangular patches often influences the integrity of complex vascular structures, leading to suboptimal segmentation accuracy. To address this challenge, we propose the adaptive Morph Patch Transformer (MPT), a novel architecture specifically designed for aortic vascular segmentation. Specifically, MPT introduces an adaptive patch partitioning strategy that dynamically generates morphology-aware patches aligned with complex vascular structures. This strategy can preserve semantic integrity of complex vascular structures within individual patches. Moreover, a Semantic Clustering Attention (SCA) method is proposed to dynamically aggregate features from various patches with similar semantic characteristics. This method enhances the model's capability to segment vessels of varying sizes, preserving the integrity of vascular structures. Extensive experiments on three open-source dataset(AVT, AortaSeg24 and TBAD) demonstrate that MPT achieves state-of-the-art performance, with improvements in segmenting intricate vascular structures.

6.8CVApr 28
TopoMamba: Topology-Aware Scanning and Fusion for Segmenting Heterogeneous Medical Visual Media

Fuchen Zheng, Chengpei Xu, Long Ma et al.

Visual state-space models (SSMs) have shown strong potential for medical image segmentation, yet their effectiveness is often limited by two practical issues: axis-biased scan ordering weakens the modeling of oblique and curved structures, and naive multi-branch fusion tends to amplify redundant responses. We present TopoMamba, a topology-aware scan-and-fuse framework for segmenting heterogeneous medical visual media. The method combines a diagonal/anti-diagonal TopoA-Scan branch with the standard Cross-Scan branch to provide complementary structural priors, and introduces ScanCache, a device-aware caching mechanism that amortizes explicit scan-index construction across recurring resolutions. To fuse heterogeneous scan features efficiently, we further propose a lightweight HSIC Gate that regulates branch interaction using a dependence-aware scalar gating rule. We also instantiate a volumetric TopoMamba-3D for practical 3D clinical segmentation. Experiments on Synapse CT, ISIC 2017 dermoscopy, and CVC-ClinicDB endoscopy show that TopoMamba consistently improves segmentation quality over strong CNN, Transformer, and SSM baselines, with particularly clear gains on thin or curved targets such as the pancreas and gallbladder, while maintaining favorable deployment efficiency under dynamic input resolutions. These results suggest that topology-aware scan ordering and lightweight dependence-aware fusion form an effective and practical design for medical multimedia segmentation. The code will be made publicly available.