Alzahra Altalib

h-index1
3papers
12citations

3 Papers

4.8CVMay 19
EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis

Alzahra Altalib, Chunhui Li, Haytham Al Ewaidat et al.

Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows.

16.7IVJan 22, 2025
Synthetic CT image generation from CBCT: A Systematic Review

Alzahra Altalib, Scott McGregor, Chunhui Li et al.

The generation of synthetic CT (sCT) images from cone-beam CT (CBCT) data using deep learning methodologies represents a significant advancement in radiation oncology. This systematic review, following PRISMA guidelines and using the PICO model, comprehensively evaluates the literature from 2014 to 2024 on the generation of sCT images for radiation therapy planning in oncology. A total of 35 relevant studies were identified and analyzed, revealing the prevalence of deep learning approaches in the generation of sCT. This review comprehensively covers synthetic CT generation based on CBCT and proton-based studies. Some of the commonly employed architectures explored are convolutional neural networks (CNNs), generative adversarial networks (GANs), transformers, and diffusion models. Evaluation metrics including mean absolute error (MAE), root mean square error (RMSE), peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) consistently demonstrate the comparability of sCT images with gold-standard planning CTs (pCT), indicating their potential to improve treatment precision and patient outcomes. Challenges such as field-of-view (FOV) disparities and integration into clinical workflows are discussed, along with recommendations for future research and standardization efforts. In general, the findings underscore the promising role of sCT-based approaches in personalized treatment planning and adaptive radiation therapy, with potential implications for improved oncology treatment delivery and patient care.

0.9CVJun 11
Dual-Domain Equivariant Generative Adversarial Network for Multimodal CT-PET Synthesis

Gabriel Steele, Alzahra Altalib, Alessandro Perelli

We present a Dual-Domain Equivariant Generative Adversarial Network (DDE-GAN) for multimodal CT-PET image synthesis. Traditional GAN-based approaches often operate solely in the spatial domain and ignore geometric consistency, resulting in limited structural fidelity. DDE-GAN addresses these challenges by jointly learning from both spatial and frequency (Fourier) domains, capturing complementary anatomical and spectral information. Furthermore, rotational equivariance embedded in the physics of the CT and PET measurements are integrated into the loss of both the generator and discriminator to ensure consistent responses under rotations, improving anatomical accuracy. A hierarchical dual-domain training strategy enforces intra- and inter-domain consistency through multi-stage loss functions. Evaluated on the HECKTOR 2022 CT-PET dataset, DDE-GAN achieves superior synthesis quality over baseline models for CT-PET image synthesis. The results demonstrate that combining dual-domain learning with geometric equivariance substantially enhances multimodal image synthesis accuracy and robustness, enabling practical applications in PET completion and data augmentation.