CVOct 12, 2023
Worst-Case Morphs using Wasserstein ALI and Improved MIPGANUna M. Kelly, Meike Nauta, Lu Liu et al.
A morph is a combination of two separate facial images and contains identity information of two different people. When used in an identity document, both people can be authenticated by a biometric Face Recognition (FR) system. Morphs can be generated using either a landmark-based approach or approaches based on deep learning such as Generative Adversarial Networks (GAN). In a recent paper, we introduced a \emph{worst-case} upper bound on how challenging morphing attacks can be for an FR system. The closer morphs are to this upper bound, the bigger the challenge they pose to FR. We introduced an approach with which it was possible to generate morphs that approximate this upper bound for a known FR system (white box), but not for unknown (black box) FR systems. In this paper, we introduce a morph generation method that can approximate worst-case morphs even when the FR system is not known. A key contribution is that we include the goal of generating difficult morphs \emph{during} training. Our method is based on Adversarially Learned Inference (ALI) and uses concepts from Wasserstein GANs trained with Gradient Penalty, which were introduced to stabilise the training of GANs. We include these concepts to achieve similar improvement in training stability and call the resulting method Wasserstein ALI (WALI). We finetune WALI using loss functions designed specifically to improve the ability to manipulate identity information in facial images and show how it can generate morphs that are more challenging for FR systems than landmark- or GAN-based morphs. We also show how our findings can be used to improve MIPGAN, an existing StyleGAN-based morph generator.
3.9CVApr 16
Find the Differences: Differential Morphing Attack Detection vs Face RecognitionUna M. Kelly, Luuk J. Spreeuwers, Raymond N. J. Veldhuis
Morphing is a challenge to face recognition (FR) for which several morphing attack detection solutions have been proposed. We argue that face recognition and differential morphing attack detection (D-MAD) in principle perform very similar tasks, which we support by comparing an FR system with two existing D-MAD approaches. We also show that currently used decision thresholds inherently lead to FR systems being vulnerable to morphing attacks and that this explains the tradeoff between performance on normal images and vulnerability to morphing attacks. We propose using FR systems that are already in place for morphing detection and introduce a new evaluation threshold that guarantees an upper limit to the vulnerability to morphing attacks - even of unknown types.
CVFeb 8, 2024
Efficient Expression Neutrality Estimation with Application to Face Recognition Utility PredictionMarcel Grimmer, Raymond N. J. Veldhuis, Christoph Busch
The recognition performance of biometric systems strongly depends on the quality of the compared biometric samples. Motivated by the goal of establishing a common understanding of face image quality and enabling system interoperability, the committee draft of ISO/IEC 29794-5 introduces expression neutrality as one of many component quality elements affecting recognition performance. In this study, we train classifiers to assess facial expression neutrality using seven datasets. We conduct extensive performance benchmarking to evaluate their classification and face recognition utility prediction abilities. Our experiments reveal significant differences in how each classifier distinguishes "neutral" from "non-neutral" expressions. While Random Forests and AdaBoost classifiers are most suitable for distinguishing neutral from non-neutral facial expressions with high accuracy, they underperform compared to Support Vector Machines in predicting face recognition utility.
CRJan 26, 2021
Biometric Verification Secure Against Malicious AdversariesAmina Bassit, Florian Hahn, Joep Peeters et al.
Biometric verification has been widely deployed in current authentication solutions as it proves the physical presence of individuals. To protect the sensitive biometric data in such systems, several solutions have been developed that provide security against honest-but-curious (semi-honest) attackers. However, in practice attackers typically do not act honestly and multiple studies have shown drastic biometric information leakage in such honest-but-curious solutions when considering dishonest, malicious attackers. In this paper, we propose a provably secure biometric verification protocol to withstand malicious attackers and prevent biometric data from any sort of leakage. The proposed protocol is based on a homomorphically encrypted log likelihood-ratio-based (HELR) classifier that supports any biometric modality (e.g. face, fingerprint, dynamic signature, etc.) encoded as a fixed-length real-valued feature vector and performs an accurate and fast biometric recognition. Our protocol, that is secure against malicious adversaries, is designed from a protocol secure against semi-honest adversaries enhanced by zero-knowledge proofs. We evaluate both protocols for various security levels and record a sub-second speed (between $0.37$s and $0.88$s) for the protocol against semi-honest adversaries and between $0.95$s and $2.50$s for the protocol secure against malicious adversaries.
IVJan 13, 2020
Deep convolutional neural networks for multi-planar lung nodule detection: improvement in small nodule identificationSunyi Zheng, Ludo J. Cornelissen, Xiaonan Cui et al.
Objective: In clinical practice, small lung nodules can be easily overlooked by radiologists. The paper aims to provide an efficient and accurate detection system for small lung nodules while keeping good performance for large nodules. Methods: We propose a multi-planar detection system using convolutional neural networks. The 2-D convolutional neural network model, U-net++, was trained by axial, coronal, and sagittal slices for the candidate detection task. All possible nodule candidates from the three different planes are combined. For false positive reduction, we apply 3-D multi-scale dense convolutional neural networks to efficiently remove false positive candidates. We use the public LIDC-IDRI dataset which includes 888 CT scans with 1186 nodules annotated by four radiologists. Results: After ten-fold cross-validation, our proposed system achieves a sensitivity of 94.2% with 1.0 false positive/scan and a sensitivity of 96.0% with 2.0 false positives/scan. Although it is difficult to detect small nodules (i.e. < 6 mm), our designed CAD system reaches a sensitivity of 93.4% (95.0%) of these small nodules at an overall false positive rate of 1.0 (2.0) false positives/scan. At the nodule candidate detection stage, results show that a multi-planar method is capable to detect more nodules compared to using a single plane. Conclusion: Our approach achieves good performance not only for small nodules, but also for large lesions on this dataset. This demonstrates the effectiveness and efficiency of our developed CAD system for lung nodule detection. Significance: The proposed system could provide support for radiologists on early detection of lung cancer.
CVApr 11, 2019
Automatic Pulmonary Nodule Detection in CT Scans Using Convolutional Neural Networks Based on Maximum Intensity ProjectionSunyi Zheng, Jiapan Guo, Xiaonan Cui et al.
Accurate pulmonary nodule detection is a crucial step in lung cancer screening. Computer-aided detection (CAD) systems are not routinely used by radiologists for pulmonary nodule detection in clinical practice despite their potential benefits. Maximum intensity projection (MIP) images improve the detection of pulmonary nodules in radiological evaluation with computed tomography (CT) scans. Inspired by the clinical methodology of radiologists, we aim to explore the feasibility of applying MIP images to improve the effectiveness of automatic lung nodule detection using convolutional neural networks (CNNs). We propose a CNN-based approach that takes MIP images of different slab thicknesses (5 mm, 10 mm, 15 mm) and 1 mm axial section slices as input. Such an approach augments the two-dimensional (2-D) CT slice images with more representative spatial information that helps discriminate nodules from vessels through their morphologies. Our proposed method achieves sensitivity of 92.67% with 1 false positive per scan and sensitivity of 94.19% with 2 false positives per scan for lung nodule detection on 888 scans in the LIDC-IDRI dataset. The use of thick MIP images helps the detection of small pulmonary nodules (3 mm-10 mm) and results in fewer false positives. Experimental results show that utilizing MIP images can increase the sensitivity and lower the number of false positives, which demonstrates the effectiveness and significance of the proposed MIP-based CNNs framework for automatic pulmonary nodule detection in CT scans. The proposed method also shows the potential that CNNs could gain benefits for nodule detection by combining the clinical procedure.
CRMay 28, 2017
Fast and Accurate Likelihood Ratio Based Biometric Comparison in the Encrypted DomainJoep Peeters, Andreas Peter, Raymond N. J. Veldhuis
As applications of biometric verification proliferate, users become more vulnerable to privacy infringement. Biometric data is very privacy sensitive as it may contain information as gender, ethnicity and health conditions which should not be shared with third parties during the verification process. Moreover, biometric data that has fallen into the wrong hands often leads to identity theft. Secure biometric verification schemes try to overcome such privacy threats. Unfortunately, existing secure solutions either introduce a heavy computational or communication overhead or have to accept a high loss in accuracy; both of which make them impractical in real-world settings. This paper presents a novel approach to secure biometric verification aiming at a practical trade-off between efficiency and accuracy, while guaranteeing full security against honest-but-curious adversaries. The system performs verification in the encrypted domain using elliptic curve based homomorphic ElGamal encryption for high efficiency. Classification is based on a log-likelihood ratio classifier which has proven to be very accurate. No private information is leaked during the verification process using a two-party secure protocol. Initial tests show highly accurate results that have been computed within milliseconds range.