2.8CVFeb 19
FoundationPose-Initialized 3D-2D Liver Registration for Surgical Augmented RealityHanyuan Zhang, Lucas He, Runlong He et al.
Augmented reality can improve tumor localization in laparoscopic liver surgery. Existing registration pipelines typically depend on organ contours; deformable (non-rigid) alignment is often handled with finite-element (FE) models coupled to dimensionality-reduction or machine-learning components. We integrate laparoscopic depth maps with a foundation pose estimator for camera-liver pose estimation and replace FE-based deformation with non-rigid iterative closest point (NICP) to lower engineering/modeling complexity and expertise requirements. On real patient data, the depth-augmented foundation pose approach achieved 9.91 mm mean registration error in 3 cases. Combined rigid-NICP registration outperformed rigid-only registration, demonstrating NICP as an efficient substitute for finite-element deformable models. This pipeline achieves clinically relevant accuracy while offering a lightweight, engineering-friendly alternative to FE-based deformation.
5.3CVApr 11
Warm-Started Reinforcement Learning for Iterative 3D/2D Liver RegistrationHanyuan Zhang, Lucas He, Zijie Cheng et al.
Registration between preoperative CT and intraoperative laparoscopic video plays a crucial role in augmented reality (AR) guidance for minimally invasive surgery. Learning-based methods have recently achieved registration errors comparable to optimization-based approaches while offering faster inference. However, many supervised methods produce coarse alignments that rely on additional optimization-based refinement, thereby increasing inference time. We present a discrete-action reinforcement learning (RL) framework that formulates CT-to-video registration as a sequential decision-making process. A shared feature encoder, warm-started from a supervised pose estimation network to provide stable geometric features and faster convergence, extracts representations from CT renderings and laparoscopic frames, while an RL policy head learns to choose rigid transformations along six degrees of freedom and to decide when to stop the iteration. Experiments on a public laparoscopic dataset demonstrated that our method achieved an average target registration error (TRE) of 15.70 mm, comparable to supervised approaches with optimization, while achieving faster convergence. The proposed RL-based formulation enables automated, efficient iterative registration without manually tuned step sizes or stopping criteria. This discrete framework provides a practical foundation for future continuous-action and deformable registration models in surgical AR applications.