Han Li

CL
4papers
1citation
Novelty53%
AI Score47

4 Papers

2.3IRFeb 28Code
MuonRec: Shifting the Optimizer Paradigm Beyond Adam in Scalable Generative Recommendation

Rong Shan, Aofan Yu, Bo Chen et al.

Recommender systems (RecSys) are increasingly emphasizing scaling, leveraging larger architectures and more interaction data to improve personalization. Yet, despite the optimizer's pivotal role in training, modern RecSys pipelines almost universally default to Adam/AdamW, with limited scrutiny of whether these choices are truly optimal for recommendation. In this work, we revisit optimizer design for scalable recommendation and introduce MuonRec, the first framework that brings the recently proposed Muon optimizer to RecSys training. Muon performs orthogonalized momentum updates for 2D weight matrices via Newton-Schulz iteration, promoting diverse update directions and improving optimization efficiency. We develop an open-source training recipe for recommendation models and evaluate it across both traditional sequential recommenders and modern generative recommenders. Extensive experiments demonstrate that MuonRec reduces converged training steps by an average of 32.4\% while simultaneously improving final ranking quality. Specifically, MuonRec yields consistent relative gains in NDCG@10, averaging 12.6\% across all settings, with particularly pronounced improvements in generative recommendation models. These results consistently outperform strong Adam/AdamW baselines, positioning Muon as a promising new optimizer standard for RecSys training. Our code is available.

1.5CVMar 2
MMNavAgent: Multi-Magnification WSI Navigation Agent for Clinically Consistent Whole-Slide Analysis

Zhengyang Xu, Han Li, Jingsong Liu et al.

Recent AI navigation approaches aim to improve Whole-Slide Image (WSI) diagnosis by modeling spatial exploration and selecting diagnostically relevant regions, yet most operate at a single fixed magnification or rely on predefined magnification traversal. In clinical practice, pathologists examine slides across multiple magnifications and selectively inspect only necessary scales, dynamically integrating global and cellular evidence in a sequential manner. This mismatch prevents existing methods from modeling cross-magnification interactions and adaptive magnification selection inherent to real diagnostic workflows. To these, we propose a clinically consistent Multi-Magnification WSI Navigation Agent (MMNavAgent) that explicitly models multi magnification interaction and adaptive magnification selection. Specifically, we introduce a Cross-Magnification navigation Tool (CMT) that aggregates contextual information from adjacent magnifications to enhance discriminative representations along the navigation path. We further introduce a Magnification Selection Tool (MST) that leverages memory-driven reasoning within the agent framework to enable interactive and adaptive magnification selection, mimicking the sequential decision process of pathologists. Extensive experiments on a public dataset demonstrate improved diagnostic performance, with 1.45% gain of AUC and 2.93% gain of BACC over a non-agent baseline. Code will be public upon acceptance.

1.1CLMar 2
ClinConsensus: A Consensus-Based Benchmark for Evaluating Chinese Medical LLMs across Difficulty Levels

Xiang Zheng, Han Li, Wenjie Luo et al.

Large language models (LLMs) are increasingly applied to health management, showing promise across disease prevention, clinical decision-making, and long-term care. However, existing medical benchmarks remain largely static and task-isolated, failing to capture the openness, longitudinal structure, and safety-critical complexity of real-world clinical workflows. We introduce ClinConsensus, a Chinese medical benchmark curated, validated, and quality-controlled by clinical experts. ClinConsensus comprises 2500 open-ended cases spanning the full continuum of care--from prevention and intervention to long-term follow-up--covering 36 medical specialties, 12 common clinical task types, and progressively increasing levels of complexity. To enable reliable evaluation of such complex scenarios, we adopt a rubric-based grading protocol and propose the Clinically Applicable Consistency Score (CACS@k). We further introduce a dual-judge evaluation framework, combining a high-capability LLM-as-judge with a distilled, locally deployable judge model trained via supervised fine-tuning, enabling scalable and reproducible evaluation aligned with physician judgment. Using ClinConsensus, we conduct a comprehensive assessment of several leading LLMs and reveal substantial heterogeneity across task themes, care stages, and medical specialties. While top-performing models achieve comparable overall scores, they differ markedly in reasoning, evidence use, and longitudinal follow-up capabilities, and clinically actionable treatment planning remains a key bottleneck. We release ClinConsensus as an extensible benchmark to support the development and evaluation of medical LLMs that are robust, clinically grounded, and ready for real-world deployment.

1.2PFFeb 28
GCL-Sampler: Discovering Kernel Similarity for Sampled GPU Simulation via Graph Contrastive Learning

Jiaqi Wang, Jingwei Sun, Jiyu Luo et al.

GPU architectural simulation is orders of magnitude slower than native execution, necessitating workload sampling for practical speedups. Existing methods rely on hand-crafted features with limited expressiveness, yielding either aggressive sampling with high errors or conservative sampling with constrained speedups. To address these issues, we propose GCL-Sampler, a sampling framework that leverages Relational Graph Convolutional Networks with contrastive learning to automatically discover high-dimensional kernel similarities from trace graphs. By encoding instruction sequences and data dependencies into graph embeddings, GCL-Sampler captures rich structural and semantic properties of program execution, enabling both high fidelity and substantial speedup. Evaluations on extensive benchmarks show that GCL-Sampler achieves 258.94x average speedup against full workload with 0.37% error, outperforming state-of-the-art methods, PKA (129.23x, 20.90%), Sieve (94.90x, 4.10%) and STEM+ROOT (56.57x, 0.38%).