Yidi Li

2papers

2 Papers

7.0SPMar 17
EMPD: An Event-based Multimodal Physiological Dataset for Remote Pulse Wave Detection

Qian Feng, Pengfei Li, Rongshan Gao et al.

Remote photoplethysmography (rPPG) based on traditional frame-based cameras often struggles with motion artifacts and limited temporal resolution. To address these limitations, we introduce EMPD (Event-based Multimodal Physiological Dataset), the first benchmark dataset specifically designed for non-contact physiological sensing via event cameras. The dataset leverages a laser-assisted acquisition system where a high-coherence laser modulates subtle skin vibrations from the radial artery into significant signals detectable by a neuromorphic sensor. The hardware platform integrates a high-resolution event camera to capture micro-motions and intensity transients, an industrial RGB camera to provide traditional rPPG benchmarks, and a clinical-grade pulse oximeter to record ground truth PPG waveforms. EMPD contains 193 valid records collected from 83 subjects, covering a wide heart rate range (40-110 BPM) under both resting and post-exercise conditions. By providing precisely synchronized multimodal data with microsecond-level temporal precision, EMPD serves as a crucial resource for developing robust algorithms in the field of neuromorphic physiological monitoring. The dataset is publicly available at: https://doi.org/10.5281/zenodo.18765701

3.2CVJun 14
Fusion-E2Pulse: A Multimodal Event-RGB Fusion Network for Non-contact Pulse Wave Reconstruction

Qian Feng, Hao Guo, Yan Niu et al.

Non-contact pulse wave reconstruction hinges on the precise recovery of waveform morphology, including the dicrotic notch. Conventional Red-Green-Blue (RGB)-based methods, which extract physiological signals from recorded facial videos, are constrained by the integral imaging mechanism of standard cameras, where the exposure process induces a smoothing effect that attenuates subtle vascular pulsation details. Conversely, neuromorphic event cameras, while offering exceptional sensitivity to intensity fluctuations, are inherently susceptible to noise and artifacts induced by minor motion. To exploit the synergy between frame-based integration and event-based differential sensing, we propose a novel multimodal network named Fusion-E2Pulse. This framework utilizes filtered RGB signals as structural priors to suppress motion artifacts, while leveraging the high-sensitivity of event streams to recover fine-grained morphological details. Experimental results demonstrate that Fusion-E2Pulse achieves state-of-the-art performance, effectively balancing noise suppression and morphological fidelity, achieving a mean absolute error of 0.78 bpm for heart rate estimation, a waveform correlation of 0.89, and a systolic phase duration error of 16.74 ms, validating its efficacy in reconstructing fine-grained pathological features.