Alison L. Marsden

2papers

2 Papers

7.0CEMay 21Code
SDFStent: Real-time interactive virtual stenting via SDF deformation fields

Bohan J. Li, Nicholas C. Dorn, Andras Lasso et al.

Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry. The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on three tetralogy of Fallot (ToF) patients and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements. Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 $\pm$ 0.08 mm in 1.5 s, over 100$\times$ faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg). SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.

1.1FLU-DYNJul 2
Comparative analysis of resistive immersed surface and immersed boundary methods for aortic valve simulation

Han Zhao, Alexander D. Kaiser, Fanwei Kong et al.

Numerical modeling of aortic valve dynamics is essential for understanding the complex fluid-structure interaction (FSI) governing valve biomechanics in health and disease. Immersed methods provide a flexible computational framework for simulating the large deformations of valve leaflets and associated blood flow without requiring body-fitted meshes. Among these approaches, the Resistive Immersed Surface (RIS) and Immersed Boundary (IB) methods are widely used. However, systematic comparative analysis of these methods for realistic aortic valve simulations has not been performed. In this work, we compare a prescribed-kinematics RIS workflow implemented in SimVascular's svMultiPhysics solver with a fully coupled IB workflow using IBAMR for trileaflet and bicuspid aortic valve configurations. The RIS method represents the valve as a surface with prescribed kinematics embedded in the fluid domain and introduces a penalty force that drives the surrounding fluid velocity toward the prescribed leaflet velocity. This formulation reduces modeling complexity and provides useful hemodynamic predictions when representative leaflet kinematics are available. In contrast, the IB method models the leaflets as elastic structures fully immersed in the fluid domain and resolves leaflet deformation through fully coupled two-way FSI. The study focuses on the extent to which RIS reproduces bulk hemodynamic features and transvalvular pressure gradients. Results show that the RIS method captures the large-scale flow structures and predicts the mean transvalvular pressure gradient with a relative error within 15% of the fully coupled IB simulation, improving to within 5% when inlet boundary conditions are matched, while reducing computational cost by approximately 60%.