AIJan 15Code
MHub.ai: A Simple, Standardized, and Reproducible Platform for AI Models in Medical ImagingLeonard Nürnberg, Dennis Bontempi, Suraj Pai et al.
Artificial intelligence (AI) has the potential to transform medical imaging by automating image analysis and accelerating clinical research. However, research and clinical use are limited by the wide variety of AI implementations and architectures, inconsistent documentation, and reproducibility issues. Here, we introduce MHub.ai, an open-source, container-based platform that standardizes access to AI models with minimal configuration, promoting accessibility and reproducibility in medical imaging. MHub.ai packages models from peer-reviewed publications into standardized containers that support direct processing of DICOM and other formats, provide a unified application interface, and embed structured metadata. Each model is accompanied by publicly available reference data that can be used to confirm model operation. MHub.ai includes an initial set of state-of-the-art segmentation, prediction, and feature extraction models for different modalities. The modular framework enables adaptation of any model and supports community contributions. We demonstrate the utility of the platform in a clinical use case through comparative evaluation of lung segmentation models. To further strengthen transparency and reproducibility, we publicly release the generated segmentations and evaluation metrics and provide interactive dashboards that allow readers to inspect individual cases and reproduce or extend our analysis. By simplifying model use, MHub.ai enables side-by-side benchmarking with identical execution commands and standardized outputs, and lowers the barrier to clinical translation.
47.0CVMay 2
Exploring Prompt Alignment with Clinical Factors in Zero-Shot Segmentation VLMs for NSCLC Tumor SegmentationSuraj Pai, Thibault Heintz, Cosmin Ciausu et al.
Zero-shot vision-language models (VLMs) offer a promptable alternative to task-specific training for gross tumor volume (GTV) delineation in non-small-cell lung cancer (NSCLC), but the prompt dimensions that govern their spatial behavior remain poorly understood. We study this question by probing alignment directions in VoxTell on a held-out internal NSCLC tumor dataset through sub-prompt decomposition into diagnosis, demographic, staging, anatomical, generic, and irrelevant controls; attribute-wise perturbation robustness; specificity ladders; and cross-case prompt swaps, while benchmarking against fine-tuned and zero-shot baselines using the Dice Similarity Coefficient (DSC) with Wilcoxon signed-rank tests and Benjamini-Hochberg correction. Alignment analyses revealed that anatomical location is the dominant driver of VoxTell's spatial attention: 63.4 percent of location perturbations caused catastrophic drops, prompt specificity improved from generic to full descriptions except for diagnosis-only prompts, irrelevant prompts correctly yielded zero segmentation, and cross-case prompt swaps confirmed patient-specific conditioning (matched DSC 0.906 vs. mismatched 0.406). Histology and stage substitutions had minimal effect, indicating that the model prioritizes "where to look" over "what to look for." In this context, VoxTell, operating fully zero-shot, achieved a mean DSC of 0.613, statistically indistinguishable from nnUNet (0.690, adjusted p = 0.156) and Ahmed et al. (0.675, adjusted p = 0.679), while significantly outperforming all other zero-shot models. Together, these findings argue that segmentation VLMs should be evaluated not only by Dice, but also by the prompt dimensions to which they align.