1.5CVMar 4
ProFound: A moderate-sized vision foundation model for multi-task prostate imagingYipei Wang, Yinsong Xu, Weixi Yi et al.
Many diagnostic and therapeutic clinical tasks for prostate cancer increasingly rely on multi-parametric MRI. Automating these tasks is challenging because they necessitate expert interpretations, which are difficult to scale to capitalise on modern deep learning. Although modern automated systems achieve expert-level performance in isolated tasks, their general clinical utility remains limited by the requirement of large task-specific labelled datasets. In this paper, we present ProFound, a domain-specialised vision foundation model for volumetric prostate mpMRI. ProFound is pre-trained using several variants of self-supervised approaches on a diverse, multi-institutional collection of 5,000 patients, with a total of over 22,000 unique 3D MRI volumes (over 1,800,000 2D image slices). We conducted a systematic evaluation of ProFound across a broad spectrum of $11$ downstream clinical tasks on over 3,000 independent patients, including prostate cancer detection, Gleason grading, lesion localisation, gland volume estimation, zonal and surrounding structure segmentation. Experimental results demonstrate that finetuned ProFound consistently outperforms or remains competitive with state-of-the-art specialised models and existing medical vision foundation models trained/finetuned on the same data.
1.5CVMar 4
MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI ReconstructionSeunghoi Kim, Chen Jin, Henry F. J. Tregidgo et al.
Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness. In many clinical workflows, complementary MRI acquisitions (e.g. high-quality structural scans) are routinely available, yet existing reconstruction methods lack mechanisms to leverage this additional information. We propose MPFlow, a zero-shot multi-modal reconstruction framework built on rectified flow that incorporates auxiliary MRI modalities at inference time without retraining the generative prior to improve anatomical fidelity. Cross-modal guidance is enabled by our proposed self-supervised pretraining strategy, Patch-level Multi-modal MR Image Pretraining (PAMRI), which learns shared representations across modalities. Sampling is jointly guided by data consistency and cross-modal feature alignment using pre-trained PAMRI, systematically suppressing intrinsic and extrinsic hallucinations. Extensive experiments on HCP and BraTS show that MPFlow matches diffusion baselines on image quality using only 20% of sampling steps while reducing tumor hallucinations by more than 15% (segmentation dice score). This demonstrates that cross-modal guidance enables more reliable and efficient zero-shot MRI reconstruction.