SYSYApr 13, 2019

A Novel Probabilistic Framework to Study the Impact of PV-battery Systems on Low-Voltage Distribution Networks

arXiv:1809.074881 citations
AI Analysis

For distribution network operators, it provides a computationally efficient method to assess the impact of residential PV-battery systems, revealing that uncoordinated scheduling does not automatically mitigate PV-induced problems.

The paper proposes a probabilistic framework using Bayesian nonparametric models and policy function approximation to simulate PV-battery systems in low-voltage networks, reducing computation time to 5% of explicit optimization methods. Results show uncoordinated battery scheduling has limited beneficial impact, contradicting common assumptions.

Battery storage, particularly residential battery storage coupled with rooftop PV, is emerging as an essential component of the smart grid technology mix. However, including battery storage and other flexible resources like electric vehicles and loads with thermal inertia into a probabilistic analysis based on Monte Carlo (MC) simulation is challenging, because their operational profiles are determined by computationally intensive optimization. Additionally, MC analysis requires a large pool of statistically-representative demand profiles to sample from. As a result, the analysis of the network impact of PV-battery systems has attracted little attention in the existing literature. To fill these knowledge gaps, this paper proposes a novel probabilistic framework to study the impact of PV-battery systems on low-voltage distribution networks. Specifically, the framework incorporates home energy management(HEM) operational decisions within the MC time series power flow analysis. First, using available smart meter data, we use a Bayesian nonparametric model to generate statistically-representative synthetic demand and PV profiles. Second, a policy function approximation that emulates battery scheduling decisions is used to make the simulation of optimization-based HEM feasible within the MC framework. The efficacy of our method is demonstrated on three representative low-voltage feeders, where the computation time to execute our MC framework is 5% of that when using explicit optimization methods in each MC sample. The assessment results show that uncoordinated battery scheduling has a limited beneficial impact, which is against the conjecture that batteries will serendipitously mitigate the technical problems induced by PV generation.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes