Automatic hip osteoarthritis grading with uncertainty estimation from computed tomography using digitally-reconstructed radiographs

arXiv:2401.00159v110 citationsh-index: 62Int J Comput Assist Radiol Surg
Originality Synthesis-oriented
AI Analysis

This work addresses the problem of subjective and time-consuming manual grading of hip osteoarthritis for clinicians, though it is incremental as it applies existing deep learning methods to a specific medical imaging task.

The researchers tackled automated grading of hip osteoarthritis severity from CT images using deep learning models on digitally-reconstructed radiographs, achieving an exact class accuracy of approximately 0.65 and a one-neighbor class accuracy of about 0.95, with model uncertainty significantly predicting classification errors.

Progression of hip osteoarthritis (hip OA) leads to pain and disability, likely leading to surgical treatment such as hip arthroplasty at the terminal stage. The severity of hip OA is often classified using the Crowe and Kellgren-Lawrence (KL) classifications. However, as the classification is subjective, we aimed to develop an automated approach to classify the disease severity based on the two grades using digitally-reconstructed radiographs (DRRs) from CT images. Automatic grading of the hip OA severity was performed using deep learning-based models. The models were trained to predict the disease grade using two grading schemes, i.e., predicting the Crowe and KL grades separately, and predicting a new ordinal label combining both grades and representing the disease progression of hip OA. The models were trained in classification and regression settings. In addition, the model uncertainty was estimated and validated as a predictor of classification accuracy. The models were trained and validated on a database of 197 hip OA patients, and externally validated on 52 patients. The model accuracy was evaluated using exact class accuracy (ECA), one-neighbor class accuracy (ONCA), and balanced accuracy.The deep learning models produced a comparable accuracy of approximately 0.65 (ECA) and 0.95 (ONCA) in the classification and regression settings. The model uncertainty was significantly larger in cases with large classification errors (P<6e-3). In this study, an automatic approach for grading hip OA severity from CT images was developed. The models have shown comparable performance with high ONCA, which facilitates automated grading in large-scale CT databases and indicates the potential for further disease progression analysis. Classification accuracy was correlated with the model uncertainty, which would allow for the prediction of classification errors.

Code Implementations1 repo
Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes