Flow-Guided Implicit Neural Representation for Motion-Aware Dynamic MRI Reconstruction
This work addresses motion artifacts in dynamic MRI for medical imaging, offering an incremental improvement by integrating flow regularization without prior estimation.
The authors tackled dynamic MRI reconstruction by jointly modeling image sequences and motion fields using implicit neural representations, achieving superior reconstruction quality and accurate motion estimation compared to state-of-the-art methods.
Dynamic magnetic resonance imaging (dMRI) captures temporally-resolved anatomy but is often challenged by limited sampling and motion-induced artifacts. Conventional motion-compensated reconstructions typically rely on pre-estimated optical flow, which is inaccurate under undersampling and degrades reconstruction quality. In this work, we propose a novel implicit neural representation (INR) framework that jointly models both the dynamic image sequence and its underlying motion field. Specifically, one INR is employed to parameterize the spatiotemporal image content, while another INR represents the optical flow. The two are coupled via the optical flow equation, which serves as a physics-inspired regularization, in addition to a data consistency loss that enforces agreement with k-space measurements. This joint optimization enables simultaneous recovery of temporally coherent images and motion fields without requiring prior flow estimation. Experiments on dynamic cardiac MRI datasets demonstrate that the proposed method outperforms state-of-the-art motion-compensated and deep learning approaches, achieving superior reconstruction quality, accurate motion estimation, and improved temporal fidelity. These results highlight the potential of implicit joint modeling with flow-regularized constraints for advancing dMRI reconstruction.