CVAIApr 19

CDSA-Net:Collaborative Decoupling of Vascular Structure and Background for High-Fidelity Coronary Digital Subtraction Angiography

arXiv:2604.1720822.3h-index: 5Has Code
Predicted impact top 89% in CV · last 90 daysOriginality Highly original
AI Analysis

For interventional cardiologists, CDSA-Net provides high-fidelity DSA images that eliminate boundary artifacts and preserve tissue grayscale, improving diagnostic confidence and workflow efficiency.

CDSA-Net addresses motion artifacts in coronary DSA by decoupling vascular structure and background, achieving a 25.6% improvement in morphology assessment efficiency and a 42.9% gain in hemodynamic evaluation speed while maintaining diagnostic consistency with raw angiograms.

Digital subtraction angiography (DSA) in coronary imaging is fundamentally challenged by physiological motion, forcing reliance on raw angiograms cluttered with anatomical noise. Existing deep learning methods often produced images with two critical clinically unacceptable flaws: persistent boundary artifacts and a loss of native tissue grayscale fidelity that undermined diagnostic confidence. We propose a novel framework termed as CDSA-Net that for the first time explicitly decouples and jointly optimizes vascular structure preservation and realistic background restoration. CDSA-Net introduces two core innovations: (i) A hierarchical geometric prior guidance (HGPG) mechanism, embedded in our coronary structure extraction network (CSENet). It synergistically combines integrated geometric prior (IGP) with gated spatial modulation (GSM) and centerline-aware topology (CAT) loss supervision, ensuring structural continuity. (ii) An adaptive noise module (ANM) within our coronary background restoration network (CBResNet). Unlike standard restoration, ANM uniquely models the stochastic nature of clinical X-ray noise, bridging the domain gap to enable seamless background intensity estimation and the complete elimination of boundary artifacts. The final subtraction is obtained by removing the restored background from the raw angiogram. Quantitatively, it significantly outperformed state-of-the-art methods in vascular intensity correlation and perceptual quality. A 25.6% improvement in morphology assessment efficiency and a 42.9% gain in hemodynamic evaluation speed set a new benchmark for utility in interventional cardiology, while maintaining diagnostic results consistent with raw angiograms. The project code is available at https://github.com/DrThink-ai/CDSA-Net.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes