This work addresses the problem of time-consuming musculoskeletal simulation for estimating hip dynamics during gait, aiming to provide a faster alternative for clinical settings, particularly for patients with hip pathologies.

This study developed a deep learning framework to predict hip muscle forces and joint moments directly from lower-limb gait kinematics. The Transformer model achieved the best performance in healthy subjects, with an RMSE of 1.33 N/kg for muscle force and 0.11 Nm/kg for joint moment, and showed moderate predictive ability in zero-shot external validation on patients with osteonecrosis of the femoral head.

Estimating hip muscle forces and joint moments during gait typically relies on musculoskeletal simulation, which is informative but time-consuming and difficult to apply in clinical settings. This study developed a deep learning framework to predict these hip dynamics parameters directly from lower-limb gait kinematics and compared three representative sequence models under a unified protocol. Gait data were collected from 60 healthy adults under three metronome-guided cadence conditions. Ten bilateral lower-limb joint angles were used as inputs, and OpenSim-derived hip muscle forces and hip joint moments were used as reference outputs. Three deep learning models of LSTM, Transformer, and Mamba were trained and evaluated using the same subject-level split, preprocessing pipeline, and metrics. The best model was then directly tested on an external cohort of 9 patients with osteonecrosis of the femoral head (ONFH) without retraining. In the healthy-subject benchmark, Transformer achieved the best subject-level mean performance for both hip muscle force prediction (RMSE = 1.33 N/kg, MAE = 0.57 N/kg, R2 = 0.819) and hip joint moment prediction (RMSE = 0.11 Nm/kg, MAE = 0.07 Nm/kg, R2 = 0.862), with similar advantages across walking cadences. In zero-shot external validation, Transformer retained moderate predictive ability in ONFH for hip muscle force prediction (RMSE = 1.51 N/kg, MAE = 0.70 N/kg, R2 = 0.537) and hip joint moment prediction (RMSE = 0.17 Nm/kg, MAE = 0.12 Nm/kg, R2 = 0.569). These findings support the feasibility of estimating hip dynamics from gait kinematics, identify Transformer as a strong baseline, and highlight the need for broader pathological validation and improved generalization before clinical application.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes