AIJun 20

Attractor Domain Theory: A Mathematical Framework for Cardiovascular Attractor Analysis with Wearable Photoplethysmography (PPG) Validation

arXiv:2606.2203910.2
Predicted impact top 66% in AI · last 90 daysOriginality Incremental advance
AI Analysis

For researchers in cardiovascular monitoring using wearable PPG/ECG, ADT provides a principled framework to replace heuristic feature selection, though validation is limited to artifact rejection (Geometry Domain) and incremental over existing methods.

The paper introduces Attractor Domain Theory (ADT), which partitions reconstructed cardiac attractor information into three non-redundant domains (Geometry, Ergodic, Variational) and proves their sufficiency. Validation on 176,742 PPG segments achieves AUC=0.757 and NPV=0.966 after artifact correction.

The cardiovascular system evolves along a bounded trajectory in physiological state space that converges to a compact geometric object: the cardiac attractor. A wearable photoplethysmograph (PPG) or electrocardiograph (ECG) observes a one-dimensional projection of this attractor; by Takens' embedding theorem, delay coordinates reconstruct its full geometry. Three decades of nonlinear cardiac dynamics have extracted Lyapunov exponents, recurrence statistics, and sample entropy from reconstructed attractors, yet no principled account exists of which attractor properties capture which cardiovascular quantities, or why, leaving feature selection as a search problem and negative results uninterpretable. We introduce Attractor Domain Theory (ADT), which proves that the reconstructed attractor's information partitions into three mutually non-redundant domains: the Geometry Domain G (delay embedding; native capability: artifact rejection), the Ergodic Domain S (asymptotic statistical invariants; native capability: stability estimation), and the Variational Domain V (finite-time Lyapunov exponent field; native capability: hemodynamic inference). We prove a Domain Sufficiency Theorem (the Parseval analog for attractor information) and establish that three domains are necessary and sufficient. Geometry Domain validation via the SCSI framework across 176,742 PPG segments from four datasets yields AUC = 0.757 [0.686-0.828] and NPV = 0.966 after correcting three systematic evaluation artifacts (+0.179 net inflation). Ablation confirms C_NL as the dominant Geometry Domain component (Delta AUC = -0.413) and intra-domain redundancy across five components.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes